• 제목/요약/키워드: Relay Model

검색결과 233건 처리시간 0.025초

System Identification of the Hammerstein Processes for Automatic Tuning of PID Controller Using Relay Feedback

  • Koo, Doe-Gyoon;Youn, Jung-Hoon;Lee, Jie-Tae;Sung, Su-Whan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.124.3-124
    • /
    • 2001
  • The nonlinearity of several chemical processes is usually approximated by a series of the nonlinear static element and the linear subsystem. In the case of the model that the nonlinear static element precedes the linear subsystem, it is called a Hammerstein model. It is a Wiener model when the order is reserved. Here we investigate a relay feedback identification method for Hammerstein type nonlinear processes. The proposed method separates the identification of the nonlinear static function from that of the linear subsystem by using a relay feedback method. From two times activation of nonlinear processes, we identify he whole range of the nonlinear static function as well as the ultimate information of the linear subsystem.

  • PDF

컴포넌트 오브젝트 모델을 응용한 계전 알고리즘 구현방법의 개선에 관한 연구 (A Study on the Improvement of the Method for Implementing Protection Algorithm by using Component Object Model(COM))

  • 박인권;윤남선;안복신
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1210-1212
    • /
    • 1998
  • The complexity of newly developed protection algorithm and higher performance requested by the user makes the software embedded in the protective relay much harder to develop and maintain. The versatility of 32bit microprocessor and the availability of cheaper memory semiconductors introduced the fertile developing background for the protective relay developers. The use of component object model(COM) in the software developing process enables the developer to write much complex code in the easy and safe way and to maintain the code easily, too. And the aid of the COM library, the distributed computing environment will be expected to appear by the use of the COM programming model in the protective relay firmware program.

  • PDF

계전기 동특성 테스트를 위한 전력동요 모델 개발 (Development of Protective Relay Dynamic Test Model for Power Swing)

  • 김수남;이명수;이재규;유석구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.184-186
    • /
    • 2002
  • This paper presents the power swing model to dynamic test of protective relay. We propose the method of configuration of the locus of swing by change the voltage magnitude, impedance and frequency with the proposed model.

  • PDF

부분 중계노드 선택 기반의 협력 네트워크에서 증폭 후 전송 방식에 대한 성능분석 (Performance Analysis of Amplify-and-Forward Relaying in Cooperative Networks with Partial Relay Selection)

  • 황호선;안경승
    • 한국통신학회논문지
    • /
    • 제40권12호
    • /
    • pp.2317-2323
    • /
    • 2015
  • 본 논문에서는, 증폭 후 재전송하는 부분 릴레이 선택 방식의 듀얼홉 릴레이 시스템에 대한 성능을 분석한다. 증폭 후 재전송하는 릴레이 이득은 채널과 잡음을 동시에 고려한 이득이다. 수신 SNR 모델을 이용하여 닫힌형태의 end-to-end SNR 확률밀도함수와 누적분포함수를 유도한다. 또한, 부분 릴레이 선택 방식을 갖는 듀얼홉 릴레이 시스템의 정확한 닫힌 형태의 채널 용량을 분석한다. 마지막으로 본 논문의 이론적인 분석은 Monte-Carlo 시험을 통하여 검증한다.

Cooperative Nano Communication in the THz Gap Frequency Range using Wireless Power Transfer

  • Samarasekera, A. Chaminda J.;Shin, Hyundong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권10호
    • /
    • pp.5035-5057
    • /
    • 2019
  • Advancements in nanotechnology and novel nano materials in the past decade have provided a set of tools that can be used to design and manufacture integrated nano devices, which are capable of performing sensing, computing, data storing and actuation. In this paper, we have proposed cooperative nano communication using Power Switching Relay (PSR) Wireless Power Transfer (WPT) protocol and Time Switching Relay (TSR) WPT protocol over independent identically distributed (i.i.d.) Rayleigh fading channels in the Terahertz (THz) Gap frequency band to increase the range of transmission. Outage Probability (OP) performances for the proposed cooperative nano communication networks have been evaluated for the following scenarios: A) A single decode-and-forward (DF) relay for PSR protocol and TSR protocol, B) DF multi-relay network with best relay selection (BRS) for PSR protocol and TSR protocol, and C) DF multi-relay network with multiple DF hops with BRS for PSR protocol and TSR protocol. The results have shown that the transmission distance can be improved significantly by employing DF relays with WPT. They have also shown that by increasing the number of hops in a relay the OP performance is only marginally degraded. The analytical results have been verified by Monte-Carlo simulations.

On the robust adaptive linearizing control for unknown and analytic relay nonlinearity

  • Lee, Jae-Kwan;Abe, Ken-ichi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 Proceedings of the Korea Automatic Control Conference, 11th (KACC); Pohang, Korea; 24-26 Oct. 1996
    • /
    • pp.177-180
    • /
    • 1996
  • The purpose of this paper is to design a robust adaptive control algorithm for a class of systems having continuous relay nonlinearity. This continuous relay nonlinearity can be defined as an analytic nonlinear function having unknown parameters and bounded unmodeling part. By this mathematical modeling, the whole system can be considered as a nonlinear system having unknown parameters and bounded perturbation. The control algorithm of this paper, RALC, can be constructed by robust adaptive law, feedback linearization, and indirect robust adaptive control. By this RALC, we can obtain that the output of given system can follow that of a stable reference linear model made by designer and the boundedness of all signals in closed-loop system can be maintained. Therefore, we can confirm a robust adaptive control for a class of systems having continuous relay nonlinearity.

  • PDF

MMR(Mobile Multihop Relay) 시스템의 용량 분석 (Capacity Analysis of MMR(Mobile Multihop Relay) System)

  • 이강원;국광호;최송인
    • 산업공학
    • /
    • 제21권2호
    • /
    • pp.189-197
    • /
    • 2008
  • This study shows achievable capacity gain from the MMR system. Relay stations are placed along the cell boundary in tiers. We can have as many tiers of relays and as many relays in each tier as we want. A model is developed, which can estimate the system capacity varying the number of relays in each tier and the bandwidths allocated to the BS and the RS. It is shown that maximum capacity increases are 21.5% and 18.9% when we have relays in the first tier only and in the first and the second tiers, respectively.

단일 홉 릴레이 협력 스펙트럼 센싱의 성능 분석 (Performance Analysis of Single Hop Cooperative Relay Spectrum Sensing)

  • 이미선;김윤현;김진영
    • 한국위성정보통신학회논문지
    • /
    • 제7권2호
    • /
    • pp.30-35
    • /
    • 2012
  • 본 논문에서는 인지무선 통신의 스펙트럼 센싱을 위해 PU와 CR 사용자의 수신단 사이에 릴레이를 적용하여 가상의 공간 다이버시티이득(Spatial Diversity Gain)을 얻는 협력 릴레이 센싱 모델 중 여러개의 single hop AF 릴레이를 사용하는 기존 시스템 모델의 센싱 성능을 올리고자, 릴레이의 채널 상태에 따라 릴레이의 사용 유무를 선택함으로써 신뢰도 높은 다이버시티 이득을 얻는 모델을 제안하였다. 이는 Hidden terminal 환경이나, 또는 음영지역에 위치한 릴레이의 불분명한 정보를 줄임으로써 최적의 다이버시티를 얻을 수 있게 된다. 신호 검출 확률을 보임으로써 센싱 성능 향상을 보인다.

PSCAD/RTDS에서 345kV 변압기 모델링을 통한 변압기용 보호계전기의 동특성 시험 (Dynamic Performance Test of Power Transformer Protective Relay using 345kV Transformer Modelling of PSCAD/RTDS)

  • 권기백;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.120-123
    • /
    • 2005
  • This paper, for the establishment of power system models and test procedures for the dynamic performance test of transformer protective relay, presents power system model, environment establishement between RTDS and protective relay, and the dynamic performance test generated internal fault or external fault.

  • PDF

전력용 변압기에서 권선방식과 벡터그룹에 따른 보호계전기 동작원리의 그래픽 표현 (Graphical Presentation on Operation Principle of Protective Relay According to Winding Type and Vector Group in Transformer)

  • 이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1410-1412
    • /
    • 1999
  • Protective relay for transformer operates in general by comparing with the differential current and the restraint current. These kinds of currents are changed on magnitude and phasor during the fault according to winding type and vector group. This paper presents the differential and restraint currents and operational principle of differential protective relay for two-winding and three-winding transformer with graphical model. It is developed using MATLAB for an educational purpose on engineer related in power system and protection in university and power utility including large factory.