• 제목/요약/키워드: Relative signal intensity

검색결과 60건 처리시간 0.031초

Quantitative Analysis of Cerebellar Cortical Degeneration Using MRI in Dogs

  • Seok-Min Lee;A-Rim Lee;Young-Won Lee;Ho-Jung Choi
    • 한국임상수의학회지
    • /
    • 제40권3호
    • /
    • pp.225-229
    • /
    • 2023
  • In three dogs showing cerebellar ataxia, the onset of clinical signs varied from a young age of five months to age 13 years. Qualitative magnetic resonance imaging (MRI) revealed various degrees of cerebellar atrophy, and a tentative diagnosis of cerebellar cortical degeneration was made. Quantitative analysis using the brainstem to the cerebellar cross-sectional area ratio (BS:CBM ratio) and T2-signal intensity histograms were obtained to perform an objective evaluation. These techniques have the advantage of being easy and fast to evaluate. These quantitative analyses revealed the severity of cerebellar cortical degeneration in the three dogs as mild, moderate, and severe. Dogs 2 and 3 were identified as abnormal on the relative cerebrospinal fluid (CSF) space using T2-signal intensity histograms but were normal on the BS:CBM ratio. This suggests that the T2-signal intensity histograms may have higher sensitivity than BS:CBM ratio.

고압 수은등의 온도분포 측정에 대한 연구 (A study on the temperature distribution measurement of the high pressure mercury lamp)

  • 손승현;김상용;김창섭;지철근
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1990년도 추계학술발표회논문집
    • /
    • pp.35-40
    • /
    • 1990
  • Temperature distribution of high pressure mercury lamp has been mesured as a function of time using spectroscopic method. Sampling signal which is synchronized by lamp voltage was used to mesure temporal line intensity at each radius. To obtain radial temprature distribution, the mesured intensity was transformed into radial line intensity by Abel's formula. Absolute temperature profile was calculater from relative intensities of spectral lines as a function of line and tube radius. The temperature profile is very similar to the electrical tube current profile.

  • PDF

Self-seeding FP-LD을 이용한 파장 가변 레이저 광원 (Tunable laser source using a self-seeding FP-LD)

  • 김정민;이혁재
    • 융합신호처리학회논문지
    • /
    • 제22권3호
    • /
    • pp.104-109
    • /
    • 2021
  • 본 논문에서는 self-seeding FP-LD (Fabry Perot Laser Diode)를 이용하여 WDM-PON (Wavelength Division Multiplexing - Passive Optical Network)에서 사용될 수 있는 새로운 파장 가변 광원의 가능성을 검증한다. 파장 가변 광원을 이용한 WDM-PON의 기존 구현은 AWG (Arrayed Waveguide Grating) 소자의 중심 파장과 광원의 중심 파장을 세밀히 정렬해 주어야 하는 단점이 발생한다. 그러나, 본 논문에서 제안하는 파장 가변 광원은 매우 간단한 구조로 구성되며, 가변 파장이 AWG의 중심 파장에 자동 정렬되는 장점을 갖는다. 구현된 파장 가변 광원은 약 14 nm 정도 이상의 파장 가변 대역을 보였고, 상대적 세기 잡음, RIN (Relative Intensity Noise)은 최대 약 -124dB/Hz로 나타났으며, 외부 변조기를 통해 변조한 결과 10Gb/s 신호에 대한 변조 가능성을 확인 할 수 있었다.

Application of a Membrane Desolvator to the Analysis of Organic Solvents in Inductively Coupled Plasma Atomic Emission Spectrometry

  • Lee, J. S.;Lim, H. B.
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권9호
    • /
    • pp.1040-1044
    • /
    • 1999
  • A micro porous PTFE membrane desolvator (MMD) was built and evaluated for the on-line removal of organic solvents to facilitate the determination of trace metal contaminants in the solvents by ICP-AES. Three organic solvents, isopropyl alcohol (IPA), methanol, and dimethy sulfoxide (DMSO) were studied. The MMD reduced organic solvent concentration in the sample aerosol stream by 82% to 89%, as indicated by monitoring C(I) emission. Net signal intensity of Fe, Al, and Cu was increasing with higher organic solvent concentration, with the rate of increase being solvent dependent. The signal intensities for Mg and Pb followed the trend with the C(I) signal. Changing the sweep gas flow rate affected the optimum signal intensity. Wine samples were analyzed by the method of standard addition. The concentrations of B, Al, and Mg were determined with a relative precision of less than 2.3%.

원판후조직의 T1, T2 강조영상상의 상대적 신호강도와 관절통증의 상관관계 (The Relationship between Temporomandibular joint Pain and the Relative Signal Intensity of Retrodiscal Tissue on T1-, and T2-Weighted MRI Images)

  • 정재광;허윤경;최재갑
    • Journal of Oral Medicine and Pain
    • /
    • 제36권3호
    • /
    • pp.177-185
    • /
    • 2011
  • 이 연구의 목적은 측두하악관절에서 통증의 존재에 따른 T1,T2 강조 영상에서 원판후조직의 상대적 신호 강도의 연관성을 평가하는 것이다. 본 연구는 양측성 관절원판전위가 있으면서 편측성으로 관절통증을 가진 61명의 환자의 122개의 관절을 근거하여 행해졌다. 자기공명영상의 평가는 원판후조직의 신호강도의 측정과 관절원판의 위치, 삼출액, 퇴행성 변화와 같은 관절상태를 포함하였다. 원판후조직의 상대적 신호강도는 대뇌의 회질의 신호강도를 기준으로 구해졌다. 원판후조직의 상대적 신호강도와 관절통증, 개구량, 관절원판위치, 삼출액, 퇴행성 변화간의 상관성이 조사되었다. 그 결과, T1 강조 영상에서 상대적 신호강도가 비통증관절에 비해 통증관절에서 유의성있게 높게 나타났다. 또한 관절원판 전위의심도와 통증 간에 유의성 있는 상관성이 있는 것으로 나타났다. 이러한 결과는 관절원판전위 환자에서 발생하는 악관절 통증이 원판후조직의 손상과 밀접한 관련성이 있음을 시사하는 것으로서 따라서 악관절의 T1 강조영상에서 관찰되는 원판후조직의 상대적 신호강도의 크기는 악관절 통증의 존재를 나타내는 진단학적 표시자로 사용될 수 있을 것으로 생각된다.

Relative Intensity Noise Suppression of Spectrum-Sliced Channels Using Polarization-Independent Optical Modulators

  • Kim, Hyung Hwan;Manandhar, Dipen;Lee, Jae Seung
    • Journal of the Optical Society of Korea
    • /
    • 제18권6호
    • /
    • pp.646-649
    • /
    • 2014
  • Performances of spectrum-sliced channels are strongly affected by their relative intensity noise (RIN). We use polarization-independent optical modulators (PIOMs) for spectrum-sliced channels to suppress their RIN. The PIOM driven by a high sinusoidal voltage signal evenly redistributes optical frequency components in the spectral domain and reduces the RIN. It can be used at a broadband light source (BLS) output to produce spectrum-sliced channels having lower RIN values. Also, it can be used for each spectrum-sliced channel within each optical network unit (ONU). In our experiment, where 12.5-GHz-spaced spectrum-sliced channels are used in 1-GbE speed, the use of PIOM at the BLS output reduces the bit error rate (BER) of the spectrum-sliced channel by more than an order of magnitude. The use of PIOM within the ONU reduces the BER by approximately 3 orders of magnitude.

유방암 환자에서 MR Breast perfusion 영상과 시간-신호강도 곡선의 유용성 (The usability of the MR Breast perfusion image and Time-Signal Intensity curve in Breast cancer patients)

  • 조재환;이해각
    • 한국산학기술학회논문지
    • /
    • 제12권9호
    • /
    • pp.4068-4074
    • /
    • 2011
  • 본 연구는 유방암 환자를 대상으로 MR Breast perfusion 영상과 시간-신호강도 곡선의 진단적 유용성을 평가하고자 하였다. 2009년 3월부터 2010년 12월까지 조직학적으로 관상피 내암으로 진단 받은 환자 20명을 대상으로 하였다. 우선 역동적 조영 증강 영상을 획득한 후 Breast perfusion 영상을 재구성 하였다. 재구성 된 영상은 시간 강도 그래프를 획득 한 후 병변 부위, 정상 부위, 백그라운드 부위 등 세부위에서 기울기, 최대 상대 조영증강, 최대 조영 증강 시간을 측정 하였다. 실험에 대한 정량적 분석방법으로 병변 부위와 정상 부위, 백그라운드 부위의 기울기를 측정하여 평균값을 비교 분석 하였다. 정성적 분석에서는 육안적으로 각 픽셀의 신호 강도를 분석 하였고 높음(3점), 중간(2점), 낮음(1점)의 구분을 3점 척도로 실시하여 평균값을 측정하였다. 정량적 분석 결과 기울기와 최대 상대 조영증강은 병변 부위에서 가장 높았으며 최대 조영 증강 시간은 백그라운드 부위에서 가장 높았다. 정성적 분석에서는 Breast perfusion 영상은 진단적 가치가 높았다.

Pseudo Optical PAM-N Signal Using Externally Modulated Lasers

  • Huh, Joon Young;Lee, Joon Ki;Kang, Sae-Kyoung;Lee, Jyung Chan
    • ETRI Journal
    • /
    • 제37권6호
    • /
    • pp.1120-1128
    • /
    • 2015
  • We propose a pseudo optical N-level pulse-amplitude modulation (PO PAM-N) signal using a few externally-modulated lasers (EMLs) operating at different wavelengths, which is suitable for upgrading the transmission speed over an optical link of < 10 km single-mode fiber with low-cost components. To compare a PO PAM-N signal with that of a standard optical PAM-N signal, we perform experiments for evaluating the performance of a 51.56-Gb/s PO PAM-4 signal and standard 51.56-Gb/s optical PAM-4 signal. The receiver sensitivity (at $BER=10^{-5}$) of the PO PAM-4 signal is 1.5 dB better than the receiver sensitivity of a standard optical PAM-4 signal. We also investigate the feasibility of PO PAM-N (N = 4, 8, and 16) signals operating at 103.12 Gb/s, considering relative intensity noise, timing jitter, extinction ratio (ER) of EMLs, and dispersion. From the results, a PO PAM-8 signal performs better than PO PAM-4 and PO PAM-16 signals at 103.12 Gb/s. Finally, we suggest a timing control method to suppress the effect of dispersion in a PO PAM-N signal. We show that the tolerance to dispersion of a 103.12-Gb/s PO PAM-8 signal can be improved to ${\pm}40ps/nm$ by applying a proposed scheme.

KrF 레이저를 이용한 희박연소화염과 매연화염에서의 NO계측 (NO measurements in lean and soot flame using KrF laser)

  • 손성민;고동섭;이중재;오승묵;강건용;김종욱
    • 한국광학회지
    • /
    • 제12권3호
    • /
    • pp.177-183
    • /
    • 2001
  • KrF 레이저를 여기광원으로 사용하여 희박연소화염과 매연화염에서 각각 청색편이된 NO형광 신호를 측정하였다. 두 화염에 대해서 여기광의 세기와 NO 첨가량에 따른 NO 신호와 배경잡음의 세기를 계측하고 그 결과를 정성적으로 분석하였다. 또한 희박연소화염에서 위치에 따른 NO 신호의 세기도 관측하였다.

  • PDF

Chemiluminescence Determination of Balofloxacin Based on Europium (III)-Sensitized KBrO3-Na2S2O4 Reaction in Micellar Medium

  • Zhao, Fang;Qi, Yu;Xiong, Wei
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권1호
    • /
    • pp.204-208
    • /
    • 2012
  • A novel chemiluminescence (CL) flow injection method for the determination of balofloxacin is described. The method is based on the weak CL signal arising from the reaction of $KBrO_3$ with $Na_2S_2O_4$ in acidic medium being significantly enhanced by balofloxacin in the presence of europium (III) ion and sodium dodecyl benzene sulfonate (SDBS). The experimental conditions that affected CL intensity were carefully optimized and the CL reaction mechanism was briefly discussed. Under the optimum conditions, the relative CL intensity was proportional to the concentration of balofloxacin in the range of $7.0{\times}10^{-11}$ to $3.0{\times}10^{-7}g\;mL^{-1}$. The detection limit was $2.7{\times}10^{-11}g\;mL^{-1}$ and the relative standard deviation was 2.1% for $7.0{\times}10^{-10}g\;mL^{-1}$ balofloxacin (n = 13). The proposed method was successfully applied to the determination of balofloxacin in pharmaceutical formulations and biological fluids.