• Title/Summary/Keyword: Relative precision

Search Result 698, Processing Time 0.028 seconds

A Color Correct Method based on Relative Ortho Rectification Precision in High-resolution Aerial Ortho Images (항공정사영상의 상대적인 지상좌표 위치오차에 따른 색상보정)

  • Park, Sung-Hwan;Jung, Hyung-Sup;Jung, Kyungsik;Kim, Kyong-Hwi
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.5_1
    • /
    • pp.495-506
    • /
    • 2017
  • This study was carried out to effectively perform relative color correction for high-resolution aerial ortho image. For this study, relative geometrical error between adjacent images was analyzed. The block sum method is proposed to reduce the relative geometrical error. We used the regression coefficients determined based on the block sum size to perform the color correction. As a result, it was confirmed that the relative color correction was visually performed well. Quantitative analysis was performed through histogram similarity analysis. It is proved that block sum method is useful for relative color correction. Particularly, the block sum size was very important to correct color based on the amount of relative geometrical error.

Comparison of Precision for Available Phosphate Measurement between Lancaster and Soiltek KA-1 Spectrophotometric Method (Lancaster 법과 Soiltek KA-1 분광광도계를 이용한 유효인산 측정법의 정밀도 비교)

  • Hyun, Hae-Nam;Lim, Han-Cheol;Eom, Ki-Cheol;Kim, Yoo-Hak
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.32 no.3
    • /
    • pp.268-273
    • /
    • 1999
  • To measure the precision of Soiltek$^{(R)}$ KA-1 spectrophotometric measurement of soil available phosphate, standard deviation, C;V, and relative sensitivity were investigated, comparing to Lancaster method. Available phosphate concentration measured by Soiltek$^{(R)}$ KA-1 spectrophotometric method was highly correlated with Lancaster method($r=0.998^{***}$) and the slop of regression equation was close to 1.0. There were no differences in standard deviation. CV, and relative sensitivity for soil available phosphate concentrations measured by two methods. Regarding to convenience of experimental procedure and instrumental operation, and time saving analysis, Soiltek$^{(R)}$ KA-1 spectrophotometric measurement for soil available phosphate is highly recommended.

  • PDF

Compensation of the Straightness Measurement Error in the Laser Interferometer (레이저 간섭계의 진직도 측정오차 보상)

  • Khim Gyungho;Keem Tae-Ho;Lee Husang;Kim Seung-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.9 s.174
    • /
    • pp.69-76
    • /
    • 2005
  • The laser interferometer system such as HP5529A is one of the most powerful equipment fur measurement of the straightness error in precision stages. The straightness measurement system, HP5529A is composed of a Wollaston prism and a reflector. In this system, the straightness error is defined as relative lateral motion change between the prism and the reflector and computed from optical path difference of two polarized laser beams between these optics. However, rotating motion of the prism or the reflector used as a moving optic causes unwanted straightness error. In this paper, a compensation method is proposed for removing the unwanted straightness error generated by rotating the moving optic and an experiment is carried out for theoretical verification. The result shows that the unwanted straightness error becomes very large when the reflector is used as the moving optic and the distance between the reflector and the prism is far. Therefore, the prism must be generally used as the moving optic instead of the reflector so as to reduce the measurement error. Nevertheless, the measurement error must be compensated because it's not a negligible error if a rotating angle of the prism is large. In case the reflector must be used as the moving optic, which is unavoidable when the squareness error is measured between two axes, this compensation method can be applied and produces a better result.

Tool Path Control Algorithm for Aspherical Surface Grinding (비구면 가공을 위한 공구 경로 제어 알고리즘)

  • Kim H.T.;Yang H.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.100-103
    • /
    • 2005
  • In this study, tool path control algorithm for aspherical surface grinding was derived and discussed. The aspherical surface actually means contact points between lens and tool. Tool positions are generally defined at the center of a tool, so there is difference between tool path and lens surface. The path was obtained from contact angle and relative position from the contact point. The angle could be calculated after differentiating an aspheric equation and complex algebraic operations. The assumption of the control algorithm was that x moves by constant velocity while z velocity varies. X was normal to the radial direction of lens, but z was tangential. The z velocities and accelerations were determined from current error and next position in each step. In the experiment, accuracy of the control algorithm was checked on a micro-precision machine. The result showed that the control error tended to be diminished when the tool diameter increased, and the error was under sub-micro level.

  • PDF

Phase Only Pupil Filter Design Using Zernike Polynomials

  • Liu, Jiang;Miao, Erlong;Sui, Yongxin;Yang, Huaijiang
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.101-106
    • /
    • 2016
  • A pupil filter is a useful technique for modifying the light intensity distribution near the focus of an optical system to realize depth of field (DOF) extension and superresolution. In this paper, we proposed a new design of the phase only pupil filter by using Zernike polynomials. The effect of design parameters of the new filters on DOF extension and superresolution are discussed, such as defocus Strehl ratio (S.R.), superresolution factor (G) and relative first side lobe intensity (M). In comparison with the other two types of pupil filters, the proposed filter presents its advantages on controlling both the axial and radial light intensity distribution. Finally, defocused imaging simulations are carried out to further demonstrate the effectiveness and superiority of the proposed pupil filter on DOF extension and superresolution in an optical imaging system.

Study on Optical Properties of Lithium niobate using Chemical Mechanical Polishing (화학 기계적 연마에 의한 리튬 니오베이트의 광학 특성에 관한 연구)

  • Jeong, Suk-Hoon;Kim, Young-Jin;Lee, Hyun-Seop;Jeong, Hae-Do
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.121-122
    • /
    • 2008
  • Lithium Niobate (LN:LiNbO3) is a compound of niobium, lithium and oxygen. The characteristics of LN are piezoelectricity, ferroelectricity and photoelectricity, and which is widely used in surface acoustic wave (SAW). To manufacture LN device, the LN surface should be a smooth surface and defect-free because of optical property, but the LN material is processed difficult by traditional processes such as grinding and mechanical polishing (MP) because of its brittleness. To decrease defects, chemical mechanical polishing (CMP) was applied to the LN wafer. In this study, the suitable parameters scuh as pressure and relative velocity, were investigated for the LN CMP process. To improve roughness, the LN CMP was performed using the parameters that were the highest removal rate among process parameters. And, evaluation of optical property was performed by the optical reflectance and non-linear characteristic.

  • PDF

Design of Multisensor Navigation System for Autonomous Precision Approach and Landing

  • Soon, Ben K.H.;Scheding, Steve;Lee, Hyung-Keun;Lee, Hung-Kyu
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.377-382
    • /
    • 2006
  • Precision approach and landing of aircraft in a remote landing zone autonomously present several challenges. Firstly, the exact location, orientation and elevation of the landing zone are not always known; secondly, the accuracy of the navigation solution is not always sufficient for this type of precision maneuver if there is no DGPS availability within close proximity. This paper explores an alternative approach for estimating the navigation parameters of the aircraft to the landing area using only time-differenced GPS carrier phase measurement and range measurements from a vision system. Distinct ground landmarks are marked before the landing zone. The positions of these landmarks are extracted from the vision system then the ranges relative to these locations are used as measurements for the extended Kalman filter (EKF) in addition to the precise time-differenced GPS carrier phase measurements. The performance of this navigation algorithm is demonstrated using simulation.

  • PDF

Design of WWW IR System Based on Keyword Clustering Architecture (색인어 말뭉치 처리를 기반으로 한 웹 정보검색 시스템의 설계)

  • 송점동;이정현;최준혁
    • The Journal of Information Technology
    • /
    • v.1 no.1
    • /
    • pp.13-26
    • /
    • 1998
  • In general Information retrieval systems, improper keywords are often extracted and different search results are offered comparing to user's aim bacause the systems use only term frequency informations for selecting keywords and don't consider their meanings. It represents that improving precision is limited without considering semantics of keywords because recall ratio and precision have inverse proportion relation. In this paper, a system which is able to improve precision without decreasing recall ratio is designed and implemented, as client user module is introduced which can send feedbacks to server with user's intention. For this purpose, keywords are selected using relative term frequency and inverse document frequency and co-occurrence words are extracted from original documents. Then, the keywords are clustered by their semantics using calculated mutual informations. In this paper, the system can reject inappropriate documents using segmented semantic informations according to feedbacks from client user module. Consequently precision of the system is improved without decreasing recall ratio.

  • PDF

ENHANCING THE PRECISION OF GPS STATIC RELATIVE POSITIONING USING THE OCEAN TIDE LOADING CORRECTION

  • Yeh, Ta-Kang;Chang, Ming-Han;Liou, Yuei-An;Chen, Chun-Sung
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.756-759
    • /
    • 2006
  • The ocean tide loading (OTL) is an important factor for the GPS positioning, especially in the height direction. The shorter of the distance to the ocean, the larger of the error by the OTL. The influence will be changed when we measure in different place and the order of magnitude is from few centimeters to ten centimeters. In this study, more than ten kinds of the OTL models were collected and applied on the GPS static relative positioning in Taiwan. The GPS observations including five stations were obtained from Nov. 9, 2004 to Feb. 23, 2005 and we used the Bernese GPS software to execute the data processing. In this period, the average amplitudes of the 3-D coordinates are as follows: N is 0.4 cm, E is 0.7 cm, h is 1.8 cm at Kinmen station; N is 0.7 cm, E is 1.3 cm, h is 2.3 cm at Lanyu station; N is 0.5 cm, E is 0.7 cm, h is 2.0 cm at Matsu station; N is 0.6 cm, E is 0.6 cm, h is 2.0 cm at Penghu station and N is 0.5 cm, E is 1.2 cm, h is 1.7 cm at Hsinchu station. Moreover, we will analyze the advantage and disadvantage of every kind of the OTL models in different environments to offer some information to the GPS users and enhance the precision of the GPS positioning.

  • PDF

Quantitative Analysis of Lovastatin in Human Plasma and urine by Reversed-Phase High-Performance Liquid Chromatography (역상 고속액체크로마토그라프법을 이용한 혈장 및 뇨 중 로바스타틴의 정량)

  • Choi, Hye-Jin;Kim, Myoung-Min;Choi, Kyung-Eob
    • YAKHAK HOEJI
    • /
    • v.42 no.5
    • /
    • pp.473-479
    • /
    • 1998
  • Lovastatin (LOVA), a fungal metabolite isolated from cultures of Aspergillus terreus, is a competitive HMG-CoA reductase inhibitor used for the treatment of primary hyper cholesterolemia, and has also been shown to suppress growth in a variety of non-glioma tumor cell lines. A sensitive reversed-phase high-perfonnance liquid chromatographic method with ultraviolet (UV) absorbance detection has been developed to quantitate LOVA in human plasma and urine samples using liquid-liquid extraction procedure. Baseline separation of LOVA and internal standard, simvastatin was achieved on a Novapak $C_{18}$ analytical column with a mobile phase containing 0.025M $NaH_2PO_4$: CAN (35:65, v/v%), adjusted pH to 4.5. The flow rate was set at 1.5ml/min, and the column effluent was monitored by a UV detection at 238nm. The limit of quantification was determined to be 0.5${\mu}$g/ml while extraction efficiency of LOVA ranged from 73.4-82.9% at LOVA concentrations of 0.5 to 10${\mu}$g/ml. Good linearity with correlation coefficients greater than 0.999 was obtained in the range of LOVA concentrations from 0.5 to 10${\mu}$g/ml. The accuracy and the precision were proven excellent with relative standard deviation (RSD, %) and relative error (RE, %) of less than 4.2 and 4.0, respectively. Intraday precision, evaluated at five LOVA concentrations (0.5, 1, 2, 5, 10${\mu}$g/ml) and expressed as RSD ranged from 0-1.82% while the interday precision at the same concentrations ranged from 0.7-10.5%. The analytical method described was then successfully employed for the determination of LOVA concentrations in plasma samples obtained during a phase II clinical trial using high doses of LOVA (30-40mg/kg/day). This method could be further utilized for the ongoing pharmacolkinetic studies and therapeutic drug monitoring of the high-dose LOVA therapy in adenocarcinoma patients.

  • PDF