• 제목/요약/키워드: Relative contrast ratio

검색결과 75건 처리시간 0.027초

Speckle Reduction in Near-field Image of Multimode Fiber with a Piezoelectric Transducer

  • Ha, Woo-Sung;Lee, Se-Jin;Oh, Kyung-Hwan;Jung, Yong-Min;Kim, Jun-Ki
    • Journal of the Optical Society of Korea
    • /
    • 제12권3호
    • /
    • pp.126-130
    • /
    • 2008
  • We propose and experimentally demonstrate an effective method to reduce near-field speckle noise at the output of a 50 ${\mu}m$ graded index multimode fiber using a short cylindrical piezoelectric transducer(PZT) vibrating in the radial direction. The fiber was coiled as tightly as possible around the mandrel of the PZT and a periodic stretching effect was caused by the radial oscillations of the actuator. The output of the optical fiber using the He-Ne laser source was intensively observed by a CCD camera. By counting all the pixels corresponding to relative intensity graded into 256 levels in the selected area and by calculating standard deviation and mean value of the intensity, we could measure the speckle contrast and vibration effect quantitatively with reduction ratio of pixels and line profile of the illuminated region. It was clearly observed that the characteristics of the speckle pattern in the vibration-on state were significantly improved over that of the vibration-off state due to time-averaged smoothing.

Relationship between Olfactory Preferences and Olfactory Event-Related Potentials

  • Lee, Gil-Hyun;Yoon, Hae-Gyung;Kim, Young-Sam;Hyun, Kyung-Yae
    • 대한의생명과학회지
    • /
    • 제26권1호
    • /
    • pp.14-21
    • /
    • 2020
  • Quantitative evaluation of the sense of smell is done by the olfactory event-related potential (OERP) test. OERP consists of N1, P1, N2, P2, and P3, of which N1 and P1 latency are known to be affected by the concentration of odor stimuli associated with the pre-sensory phase and P2 and P3 are the stages at which odors are perceived and are known to change by subjective evaluation of the stimulus. The purpose of this study was to clarify the correlation between the expression of OERP and the subjective evaluation of the object on the fragrance stimulus using various fragrances. Therefore, the study examined the relative waveform power ratio, preference for each scent stimulus, and finally the amplitude and latency change of the components of OERP, N1 and P2. In contrast, it was found that the late P2 response waveform was an effective aroma stimulus recognition waveform in OERP compared to the initial response waveforms.

고밀도 플라즈마에 의한 PZT 박막의 식각특성 연구 (Studies on the etching characteristics of PZT thin films using inductively coupled plasma)

  • 안태현;김창일;장의구;서용진
    • 한국전기전자재료학회논문지
    • /
    • 제13권3호
    • /
    • pp.188-192
    • /
    • 2000
  • In this study PZT etching was performed using planar inductively coupled Ar/Cl$_2$/BCI$_3$ plasma. The etch rate of PZT film was 2450 $\AA$/min at Ar(20)/BCl$_3$(80) gas mixing ratio and substrate temperature of 8$0^{\circ}C$. X-ray photoelectron spectroscopy(XPS) analysis for films composition of etched PZT surface was utilized. The chemical bond of PbO is broken by ion bombardment and Cl radical, and the peak of metal Pb in a Pb 4f narrow scan begins to appear upon etching. As increasing additive BCl$_3$content the relative content of oxygen decreases rapidly in contrast with etch rate of PZT thin film. So we though that the etch rate of PZT thin film increased because abundant B and BCl radicals made volatile oxy-compound such as B$_{x}$/O$_{y}$ and/or BClO$_{x}$ bond. We achieved etch profile of about 80$^{\circ}$ at Ar(20)/BCl$_3$(80) gas mixing condition and substrate temperature of 8$0^{\circ}C$TEX>X>.

  • PDF

우리나라 성인의 음주행태와 비치명적 손상의 연관성 (Drinking Pattern and Nonfatal Injuries of Adults in Korea)

  • 이원경;김윤
    • Journal of Trauma and Injury
    • /
    • 제22권2호
    • /
    • pp.233-241
    • /
    • 2009
  • Purpose: Alcohol is a major risk factor for injuries, but little is known about the relationship between chronic drinking pattern and injuries. The purpose of this study was to evaluate the incidence of alcohol-related injuries and the differences in the characteristics of the injuries between Alcohol Use Disorder Identification Test (AUDIT) categories. Methods: Among a representative sample of the third Korea National Health and Nutrition Examination Survey. 7,697 adults answered questions about injuries, drinking patterns, and socioeconomic status. Incidences of alcohol-related injuries and of non-alcohol-related injuries were calculated, and the relative ratio of injuries between AUDIT categories was analyzed. Results: The incidences of all injuries and alcohol-related injuries were 69.2 and 6.8 per 1000 person-year. After adjustment, the incidences of non-alcohol-related injuries showed no differences between AUDIT categories. But the adjusted relative ratios (RRs) of alcohol-related injuries were 3.73 (95% CI: 1.54~8.99) and 7.70 (95% CI: 3.61~16.44) for risk drinkers and for alcohol-dependent drinkers respectively. No specific body part could be identified as being frequently injured in cases of risk drinkers and alcohol-dependent drinkers. In contrast, the adjusted RRs of fractures, bruises, and open wounds were 1.76 (95% CI: 1.03~3.02), 1.73 (95% CI: 1.15~2.61), and 1.85 (95% CI: 1.17~2.93) for alcohol-dependent drinkers. Assaults occurred 4.66 times more frequently in alcohol-dependent drinkers. Conclusion: Alcohol-related injuries occur more frequently as the person becomes more dependent on alcohol. Fractures, Bruises, open wounds, and assaults occur more frequently in alcohol-dependent drinker. This study suggests that efforts should be carried out in the ED to screen and treat alcohol-use disorders associated with patients injured after drinking.

Discrepancies in Dose-volume Histograms Generated from Different Treatment Planning Systems

  • Kim, Jung-in;Han, Ji Hye;Choi, Chang Heon;An, Hyun Joon;Wu, Hong-Gyun;Park, Jong Min
    • Journal of Radiation Protection and Research
    • /
    • 제43권2호
    • /
    • pp.59-65
    • /
    • 2018
  • Background: We analyzed changes in the doses, structure volumes, and dose-volume histograms (DVHs) when data were transferred from one commercial treatment planning system (TPS) to another commercial TPS. Materials and Methods: A total of 22 volumetric modulated arc therapy (VMAT) plans for nasopharyngeal cancer were generated with the Eclipse system using 6-MV photon beams. The computed tomography (CT) images, dose distributions, and structure information, including the planning target volume (PTV) and organs at risk (OARs), were transferred from the Eclipse to the MRIdian system in digital imaging and communications in medicine (DICOM) format. Thereafter, DVHs of the OARs and PTVs were generated in the MRIdian system. The structure volumes, dose distributions, and DVHs were compared between the MRIdian and Eclipse systems. Results and Discussion: The dose differences between the two systems were negligible (average matching ratio for every voxel with a 0.1% dose difference criterion = $100.0{\pm}0.0%$). However, the structure volumes significantly differed between the MRIdian and Eclipse systems (volume differences of $743.21{\pm}461.91%$ for the optic chiasm and $8.98{\pm}1.98%$ for the PTV). Compared to the Eclipse system, the MRIdian system generally overestimated the structure volumes (all, p < 0.001). The DVHs that were plotted using the relative structure volumes exhibited small differences between the MRIdian and Eclipse systems. In contrast, the DVHs that were plotted using the absolute structure volumes showed large differences between the two TPSs. Conclusion: DVH interpretation between two TPSs should be performed using DVHs plotted with the absolute dose and absolute volume, rather than the relative values.

The Relationship Between Night Shift Work and the Risk of Abnormal Thyroid-Stimulating Hormone: A Hospital-Based Nine-Year Follow-up Retrospective Cohort Study in Taiwan

  • Chen, Hsin-Hao;Chiu, Hsiao-Hui;Yeh, Tzu-Lin;Lin, Chi-Min;Huang, Hsin-Yi;Wu, Shang-Liang
    • Safety and Health at Work
    • /
    • 제12권3호
    • /
    • pp.390-395
    • /
    • 2021
  • Background: Health-care providers typically undergo shift work and are subjected to increased stress. Night shift work may induce disturbed sleep cycles and circadian rhythm. The objective of this study was to explore if night shift workers (NSWs) show an increased risk of abnormal thyroid-stimulating hormone (TSH). Methods: We conducted a retrospective cohort study of 574 employees without thyroid disease and abnormal TSH at baseline who underwent annual check-ups between 2007 and 2016 in a medical center. NSWs were defined as those with working time schedules other than daytime hours. We calculated the incidence rate and estimated the adjusted hazard ratio (HR) for incident abnormal TSH and subclinical hypothyroidism compared with non-NSWs using a Cox regression model. Results: A total of 56 incident abnormal TSH cases and 39 subclinical hypothyroidism cases in NSWs were identified during 3000 person-years of follow-up. In models adjusted for age, sex, obesity, and working departments, we found no increased relative risk for incident abnormal TSH (HR: 0.72, 95% confidence interval: 0.33-1.60) or subclinical hypothyroidism (HR: 0.52, 95% confidence interval: 0.19-1.45) when comparing NSWs to non-NSWs; nor were incidence rates significantly different among exclusively medical employees after excluding administrative staff. Conclusion: In this hospital-based nine-year follow-up retrospective cohort study, NSWs were not associated with increased relative risk of incident abnormal TSH and subclinical hypothyroidism, in contrast to previous cross-sectional studies.

Moyamoya 질환에서 1차 통과기법을 이용한 자기공명관류영상의 이해 (Understanding on MR Perfusion Imaging Using First Pass Technique in Moyamoya Diseases)

  • 류영환;구은회;정재은;동경래;최성현;이재승
    • 대한디지털의료영상학회논문지
    • /
    • 제12권1호
    • /
    • pp.27-31
    • /
    • 2010
  • The purpose of this study was to investigated the usefulness of MR perfusion image comparing with SPECT image. A total of pediatric 30 patients(average age : 7.8) with Moyamoya disease were performed MR Perfusion with 32 channel body coil at 3T from March 01, 2010 to June 10, 2010. The MRI sequences and parameters were as followed : gradient Echo-planar imaging(EPI), TR/TE : 2000ms/50ms, FA : $90^{\circ}$, FOV : $240{\times}240$, Matrix : $128{\times}128$, Thickness : 5mm, Gap : 1.5mm. Images were obtained contrast agent administrated at a rate of 1mL/sec after scan start 10s with a total of slice 1000 images(50 phase/1 slice). It was measured with visual color image and digitize data using MRDx software(IDL version 6.2) and also, it was compared of measurement with values of normal and abnormal ratio to analyze hemodynamic change, and a comparison between perfusion MR with technique using Warm Color at SPECT examination. On MR perfusion examination, the color images from abnormal region to the red collar with rCBV(relative cerebral blood volume) and rCBF(relative cerebral blood flow) caused by increase cerebral blood flow with brain vascular occlusion in surrounding collateral circulation advancement, the blood speed relatively was depicted slowly with blue in MTT(Mean Transit Time) and TTP(Time to Peak) images. The region which was visible abnormally from MR perfusion examination visually were detected as comparison with the same SPECT examination region, would be able to confirm the identical results in MMD(Moyamoya disease)judgments. Hymo-dynamic change in MR perfusion examination produced by increase and delay cerebral blood flow. This change with digitize data and being color imaging makes enable to distinguish between normal and abnormal area. Relatively, MR perfusion examination compared with SPECT examination could bring an excellent image with spatial resolution without radiation expose.

  • PDF

Breast Cancer Association with CYP1A2 Activity and Gene Polymorphisms - a Preliminary Case-control Study in Tunisia

  • Ayari, I;Arnaud, MJ;Mani, A;Pavanello, S;Saguem, S
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권8호
    • /
    • pp.3559-3563
    • /
    • 2015
  • The aim of the present study was to evaluate the relative contribution of CYP1A2 isoforms (-3860 G/A, -2467T/delT and -163C/A) in control subjects and breast cancer patients to the metabolism of caffeine in human liver. Restriction fragment length polymorphism analysis of PCR-amplified Fragments (PCR-RFLP) was used for the genotyping of CYP1A2 SNPs and HPLC allowed the phenotyping through the measurement of CYP1A2 activity using the 17X + 13X + 37X/137X urinary metabolite ratio (CMR) and plasma caffeine half life (T1/2). The CYP1A2 -3860A genotype was associated with a decreased risk of breast cancer. In contrast, distributions of the CYP1A2 -2467T/delT or -2467delT/delT and -163A/C or A/A genotypes among breast cancer patients and controls were similar. When the genotype and phenotype relationship was measured by comparing the mean CMR ratios and caffeine half life within the genotype groups between subjects and breast cancer patients, there were no significant differences except for -3860 A, most of them being homozygous for the -3860 G/G SNP and had a significant higher mean CMR ratio and half life than those with -3860 G/A (P=0.02). The results of this preliminary study show a significant association between CP1A2 -3860 G variant and CYP1A2 phenotype which must be confirmed by further large-size case-control studies.

Deep Learning-Based Computed Tomography Image Standardization to Improve Generalizability of Deep Learning-Based Hepatic Segmentation

  • Seul Bi Lee;Youngtaek Hong;Yeon Jin Cho;Dawun Jeong;Jina Lee;Soon Ho Yoon;Seunghyun Lee;Young Hun Choi;Jung-Eun Cheon
    • Korean Journal of Radiology
    • /
    • 제24권4호
    • /
    • pp.294-304
    • /
    • 2023
  • Objective: We aimed to investigate whether image standardization using deep learning-based computed tomography (CT) image conversion would improve the performance of deep learning-based automated hepatic segmentation across various reconstruction methods. Materials and Methods: We collected contrast-enhanced dual-energy CT of the abdomen that was obtained using various reconstruction methods, including filtered back projection, iterative reconstruction, optimum contrast, and monoenergetic images with 40, 60, and 80 keV. A deep learning based image conversion algorithm was developed to standardize the CT images using 142 CT examinations (128 for training and 14 for tuning). A separate set of 43 CT examinations from 42 patients (mean age, 10.1 years) was used as the test data. A commercial software program (MEDIP PRO v2.0.0.0, MEDICALIP Co. Ltd.) based on 2D U-NET was used to create liver segmentation masks with liver volume. The original 80 keV images were used as the ground truth. We used the paired t-test to compare the segmentation performance in the Dice similarity coefficient (DSC) and difference ratio of the liver volume relative to the ground truth volume before and after image standardization. The concordance correlation coefficient (CCC) was used to assess the agreement between the segmented liver volume and ground-truth volume. Results: The original CT images showed variable and poor segmentation performances. The standardized images achieved significantly higher DSCs for liver segmentation than the original images (DSC [original, 5.40%-91.27%] vs. [standardized, 93.16%-96.74%], all P < 0.001). The difference ratio of liver volume also decreased significantly after image conversion (original, 9.84%-91.37% vs. standardized, 1.99%-4.41%). In all protocols, CCCs improved after image conversion (original, -0.006-0.964 vs. standardized, 0.990-0.998). Conclusion: Deep learning-based CT image standardization can improve the performance of automated hepatic segmentation using CT images reconstructed using various methods. Deep learning-based CT image conversion may have the potential to improve the generalizability of the segmentation network.

주조연결된 니켈-크롬-베릴리움 주조체의 굽힘강도에 관한 비교연구 (FLEXURE STRENGTH OF CAST-JOINED CONNECTOR WITH Ni-Cr-Be ALLOY)

  • 정창모;전영찬;임장섭
    • 대한치과보철학회지
    • /
    • 제36권6호
    • /
    • pp.858-866
    • /
    • 1998
  • Soldering is the usual method used to correct an unstable fixed partial denture framework at patient's try-in; However, presoldering base metal alloys is technique-sensitve and results are unstable because it is difficult to maintain uniform heat distribution and to prevent oxidation of an alloy. A cast-joining technique has been developed by Weiss and Munyon for repair, correction and addition to base metal framework. This joining technique eliminates the problem with presoldering of non-precious frameworks. The object of this study was to 1) compare the relative flexure strength and the joining effectiveness of Ni-Cr-Be cast in two pieces and 'pre-soldered' versus in two pieces and 'cast-joined'. 2) determine the effect of increasing the number of retentive grooves on the face of the cast and 3) determine the effect of the relative matched position of groove patterns on flexure strength. The joining effectiveness can be expressed by the ratio of the mean flexure stress of soldered or cast-joined specimens to that of one-piece cast. Resin rods 3mm in diameter were used as pattern of specimens for one-piece casted, presoldered, and cast-joined groups. Cast-joined specimens had two different patterns of retentive grooves on the joined faces. Type A had cross-shaped grooves 1mm in depth. 0.6mm in width. Type B was the same except for the addition of one more retentive groove. In the experiment connecting cast-joined specimens, half of specimens with type A pattern had their patterns on the faces of paired casts matched with each other as mirror image. With the rest pairs, it was proceeded that one of paired casts turned 45 degrees so that the patterns crossed. Half of specimens with type B pattern also had the patterns matched as mirror image; However, here, one of paired casts turned 90 degrees with the other pairs. Retentive groove in this study lacked the intentional undercuts, in contrast with the suggestion of Weiss and Munyon. The specimens were subjected to four-point flexural loading in an Instron testing machine. The midspan flexural stress was calculated at the point of initial plastic strain as determined from a strip-chart recorder or at the point of failure if this occured at a lower stress level. Within the scope of this study, the following results were obtained. 1. The presoldered group showed flexural strength at least 2 times higher than the cast-joined groups. Its joining effectiveness was 82%. 2. In cast-joined groups, the flexural strength of joints with type B patterns exhibited 1.5 times that of joints with type A patterns. Joining effectivenesses were 38% for type B patterns, 25-26% for type A patterns. 3. The relative matched position of groove patterns did not have any significant effect on flexural strength of the cast-joined specimens with either type A patterns or type B patterns(p>.05).

  • PDF