• 제목/요약/키워드: Relative Thickness Ratio

검색결과 157건 처리시간 0.023초

Thermo-elastoplastic characteristics of heat-resisting functionally graded composite structures

  • Cho, Jin-Rae;Ha, Dae-Yul
    • Structural Engineering and Mechanics
    • /
    • 제11권1호
    • /
    • pp.49-70
    • /
    • 2001
  • This paper is concerned with a study on thermo-elastoplastic characteristics of functionally graded composite. Compared to the classical layered composites, it shows a wide range of thermo-elastoplastic characteristics according to the choice of two major parameters, the thickness-wise volume fraction of constituents and the relative thickness ratio of the graded layer. Therefore, by selecting an appropriate combination of the two parameters, one is expected to design the most suitable heat-resisting composite for a given thermal circumstance. Here, we address the parametric investigation on its characteristics together with theoretical study on thermo-elastoplasticity and numerical techniques for its finite element approximations. Through the numerical experiments, we examine the influence of two parameters on the thermo-elastoplastic characteristics.

전자선 치료 시 차폐블록 두께 변화에 따른 블록 주변 선량에 관한 연구 (The study on the scattering ratio at the edge of the block according to the increasing block thickness in electron therapy)

  • 박시온;곽근탁;박주경;이승훈;김양수;김정수;권형철;이선영
    • 대한방사선치료학회지
    • /
    • 제31권1호
    • /
    • pp.57-65
    • /
    • 2019
  • 목 적: 전자선 치료에서 저 용융점 납합금과 순수 납을 이용한 차폐 시 두께증가에 따른 블록 가장자리의 산란선 영향을 알아보고자 한다. 대상 및 방법: $10{\times}10cm^2$ 어플리케이터의 Insert Frame 절반을 차폐하도록 블록을 제작하였고, 두께는 각 재질당 3, 5, 10, 15, 20 (mm)로 하였다. 공통 조건을 에너지 6 MeV, 선량률 300 MU/Min, 갠트리 각도 0, 부여선량 100 MU으로 설정하였고, 블록의 위치와 측정점의 위치, 블록재질을 각각 달리하여 블록 두께증가에 따른 상대적인 산란비율을 평행평판형 전리함과 고체팬텀으로 측정하였다. 결 과: (측정 깊이 / 블록 위치 / 블록 재질)이 (표면 / 어플리케이터 / 순수 납)일 때 블록 두께가 3, 5, 10, 15, 20 (mm) 순으로 증가함에 따라 상대선량은 15.33 nC, 15.28 nC, 15.08 nC, 15.05 nC, 15.07 nC로 측정되었다. (표면 / 어플리케이터 / 합금 납)일 때 15.19 nC, 15.25 nC, 15.15 nC, 14.96 nC, 15.15 nC로 측정되었다. (표면 / 팬텀 위 / 순수 납)일 때 15.62 nC, 15.59 nC, 15.53 nC, 15.48 nC, 15.34 nC로 측정되었다. (표면 / 팬텀 위 / 합금 납)일 때 15.56 nC, 15.55 nC, 15.51 nC, 15.42 nC, 15.39 nC로 측정되었다. (심부 / 어플리케이터 / 순수 납)일 때 16.70 nC, 16.84 nC, 16.72 nC, 16.88 nC, 16.90 nC로 측정되었다. (심부 / 어플리케이터 / 합금 납)일 때 16.83 nC, 17.12 nC, 16.89 nC, 16.77 nC, 16.52 nC로 측정되었다. (심부 / 팬텀 위 / 순수 납)일 때 17.41 nC, 17.45 nC, 17.34 nC, 17.42 nC, 17.25 nC로 측정되었다. (심부 / 팬텀 위 / 합금 납)일 때 17.45 nC, 17.44 nC, 17.47 nC, 17.43 nC, 17.35 nC로 측정되었다. 결 론: 차폐블록을 이용하여 전자선 치료를 진행할 때 블록위치는 환자 체표면보다는 어플리케이터에 삽입하고 두께는 각 사용 에너지에 해당되는 최소 적정차폐두께로 제작해야 한다. 또한 블록 가장자리 경계선으로부터 떨어진 거리에 따라 변화하는 산란선의 영향을 충분히 고려하여 치료를 시행하는 것이 바람직하다고 사료된다.

Fuzzy inference based cover thickness estimation of reinforced concrete structure quantitatively considering salty environment impact

  • Do, Jeong-Yun
    • Computers and Concrete
    • /
    • 제3권2_3호
    • /
    • pp.145-161
    • /
    • 2006
  • This article involves architecting prototype-fuzzy expert system for designing the nominal cover thickness by means of fuzzy inference for quantitatively representing the environment affecting factor to reinforced concrete in chloride-induced corrosion environment. In this work, nominal cover thickness to reinforcement in concrete was determined by the sum of minimum cover thickness and tolerance to that defined from skill level, constructability and the significance of member. Several variables defining the quality of concrete and environment affecting factor (EAF) including relative humidity, temperature, cyclic wet and dry, and the distance from coast were treated as fuzzy variables. To qualify EAF the environment conditions of cycle degree of wet-dry, relative humidity, distance from coast and temperature were used as input variables. To determine the nominal cover thickness a qualified EAF, concrete grade, and watercement ratio were used. The membership functions of each fuzzy variable were generated from the engineering knowledge and intuition based on some references as well as some international codes of practice.

알루미늄 합금박판 비등온 성형공정의 유한요소해석 및 실험적 연구 (제1부. 실험) (Finite Element Analysis and Experimental Investigation of Non-isothermal Foming Processes for Aluminum-Alloy Sheet Metals(Part 1. Experiment))

  • 류호연;김영은;김종호;구본영;금영탁
    • 소성∙가공
    • /
    • 제8권2호
    • /
    • pp.152-159
    • /
    • 1999
  • This study is to investigate the effects of warm deep drawing with aluminum sheets of A1050-H16 and A5020-H32 for improving deep drawability. Experiments for producing circular cups and square cups were carried out for various working conditions, such as forming temperature and blank shapes. The limit drawing ratio(LDR) of 2.63 in warm deep drawing of circular cups in case of A5020-H32 sheet, whereas LDR of 2.25 in case of A1050-H16, could be obtained and the former was 1.4 times higher than the value at room temperature. The maximum relative drawing depth for square cups of A5020-H32 material was also about 1.92 times deeper than the depth drawn at room temperature. The effects of blank shape and forming temperature on drawability as well as thickness distribution of drawn cups were examined and discussed.

  • PDF

충격반향기법에서의 휨 모드 및 두께 모드의 영향인자에 대한 연구 (A Study on the Influence Factors on Flexural and Thickness Modes in the Impact-echo Test)

  • 오태근;박종일;변요셉;이영학
    • 한국전산구조공학회논문집
    • /
    • 제28권6호
    • /
    • pp.659-666
    • /
    • 2015
  • 본 논문에서는 콘크리트 구조물의 층상박리균열 위에서의 손상탐지에 효율적인 충격반향기법에 대해 영향을 끼치는 다양한 영향요소들에 대한 분석을 수행하였다. 충격반향기법에서의 균열 가시화를 위해 층상박리균열위의 동적거동 및 두께를 나타내는 휨 모드 및 충격반향모드(두께 모드)에 영향을 끼치는 균열의 폭/두께(a/h) 비, 균열위의 상대적 가진 점, 측정 점의 위치 등의 시험설정 변수 등을 매개변수적 유한요소해석을 통하여 조사하였다. a/h비는 2보다 클 경우 휨 모드가 지배적이었으며 작을 경우 두께 모드가 지배적이었다. 또한 가진 점, 측정 점 중 어느 하나만 균열 위에 존재할 때도 휨 모드가 지배적이었으며 균열 밖의 범위의 건전한 영역에는 가진 점, 측정 점이 모두 위치하여야 두께 모드가 지배적이었다.

Development of Broadband Electromagnetic Wave Absorber for X-band Sensors in Double-layered Type Using Carbon

  • Choi, Chang-Mook;Kim, Dong-Il;Li, Rui;Choi, Dong-Han
    • 한국항해항만학회지
    • /
    • 제30권9호
    • /
    • pp.763-766
    • /
    • 2006
  • In this paper, the EM wave absorbers were designed and fabricated for X -band sensors using Carbon of dielectric material with CPE. The complex relative permittivity of samples is calculated by using measurement results of S-parameter. We simulated the double-layered type EM wave absorber with broad bandwidth using the measured complex relative permittivity by changing the thickness and layer, which was fabricated based on the simulated design The fabricated EM wave absorber consists of 1 mm first layer sheet facing metal with Carbon composition ratio 70 vol. % and 1.5 mm second layer sheet with Carbon composition ratio 60 vol. %. The measured results showed a good agreement to the simulated ones. It is found toot the optimized absorption ability of double-layered type EM wave absorber with thickness of 2.5 mm is higher than 10 dB from 7.8 GHz to 13.3 GHz.

Development of Broad-Band Electromagnetic Wave Absorber for X-band Sensors in Double-layered Type Using Carbon

  • Choi, Chang-Mook;Kim, Dong-Il;Choi, Dong-Han;Li, Rui
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2006년도 International Symposium on GPS/GNSS Vol.1
    • /
    • pp.297-300
    • /
    • 2006
  • In this paper, the EM wave absorbers were designed and fabricated for X-band sensors using Carbon of dielectric material with CPE. The complex relative permittivity of samples is calculated by the measured S-parameter data. We simulated the double-layered type EM wave absorber with broad bandwidth using the measured complex relative permittivity by changing the thickness and layer, which was fabricated based on the simulated design. The fabricated EM wave absorber consist of 1mm first layer sheet facing metal with Carbon composition ratio 70 vol% and 1.5 mm second layer sheet with Carbon composition ratio 60 vol%. The comparisons of simulated and measured results are good agreement. As a result, the optimized absorption ability of double-layered type EM wave absorber with thickness of 2.5 mm is higher than 10 dB from 7.8 GHz to 13.3 GHz.

  • PDF

콘크리트의 블리딩에 미치는 환경 및 시공요인의 영향 (Influence of Environment and Construction Factor on the Bleeding of Concrete)

  • 황인성;김기정;나운;김규동;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.65-68
    • /
    • 2003
  • This study is intended to look into the influence of environment and construction factor on bleeding of concrete. According to the results, as wind is light, relative humidity is high and temperature is low, the amount of bleeding increases greatly, and evaporation speed is influenced greatly by order of wind, temperature and humidity. As the properties of bleeding by construction factor, the amount of bleeding increases with an increase of placing thickness, but the bleeding ratio, the amount of bleeding per unit volume, increases with a decrease of the placing thickness. Bleeding speed is fastest at about 90 minute after placing concrete. Also, as wind is light, relative humidity is high, temperature is low and the placing thickness is thick, bleeding speed grow faster.

  • PDF

강성지반위 사질토층에 위치한 얕은기초의 침하량특성분석 (Analysis of Settlement Characteristics of Shallow Foundation on Sandy Soil Overlained by Rigid Ground)

  • 황희석;김동건;유남재
    • 산업기술연구
    • /
    • 제34권
    • /
    • pp.45-52
    • /
    • 2014
  • In this paper the settlement characteristic of shallow foundation on sandy soil overlained by rigid ground was investigated by analyzing results of model tests. For model experiments, model tests were performed with sandy soils sampled from the field, changing the relative density of sandy soil and the ratio of thickness of sandy layer(H) to the width of model strip footing(B). As result of tests, settlement of sandy soils increases as the value of H/B increases, whereas it increases with relative density of soil. Bearing capacity decreases as the thickness of the sand layer relative to the footing width increases. In order to analyze the settlement characteristics of sandy ground, the results of model tests were compared with the predicted values using the empirical formulas proposed by Terzaghi, De Beer and Schmertmann. The method by De Beer was found to be in good agreements with test results.

  • PDF

X선촬영시(X線撮影時) 피사체(被寫體) 두께에 따른 격자비(格子比) 선정(選定)에 관한 연구(硏究) (Studios in Selected Grid Ratio of Objective Thickness on X-ray Exposure)

  • 윤철호;추성실;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제5권1호
    • /
    • pp.21-34
    • /
    • 1982
  • When unattenuated x-ray radiation passes through the object it is transmitted and scattered from objectes and impinging on the film. During this process certain radiation is absorbed within the object and others transmitted in reduced scattering. The scattering radiation influence upon radiation image quality, confining x-ray beam which means scattering radiation produce increased fog on x-ray film image and as a consequence decrease contrast and less detail of the film there for the elimination of fog and for absorbing scattered radiation, the grid has been used between the object and the film in order to rid of scattering rays. Using grid is good method for the qualification of the better image as well as in using air gap technique. The grid is easy to manipulate and promote good efficiency which is defined by ICRU and JIS. It is the purpose to study for eliminating scattered radiation from the tissue equivalent acryl phantom using grid, we have studied and evaluated the grid permeability about the x-ray exposure, the selection of grid ratio according to phantom thickness, on x-ray exposure are performed as follows. 1. The penetrating ratio of primary x-ray is remarkably decreased by increasing of the grid ratio, but it is almost not influenced in KVP difference and phantom thickness. 2. The scattered radiation is proportionaly increased by thickness of the phantom, having nothing to do with grid ratios. 3. The relative between the penetration rate of primary and secondary x-ray is improved by increasing grid ratio, and decreased by phantom thickness, and slightly decreased by high tube voltage. 4. The grid of 5:1 and 10:1 ratio are adequate to the phantom of 10cm and 15cm thickness, respectively.

  • PDF