• 제목/요약/키워드: Relative Power Distribution

검색결과 166건 처리시간 0.03초

A GAUSSIAN WHITE NOISE GENERATOR AND ITS APPLICATION TO THE FLUCTUATION-DISSIPATION FORMULA

  • Moon, Byung-Soo
    • Journal of applied mathematics & informatics
    • /
    • 제15권1_2호
    • /
    • pp.363-375
    • /
    • 2004
  • In this paper, We show that the bandpass random signals of the form ∑$_{\alpha}$$\alpha$$_{\alpha}$ a Sin(2$\pi$f$_{\alpha}$t + b$_{\alpha}$) where a$_{\alpha}$ being a random number in [0,1], f$_{\alpha}$ a random integer in a given frequency band, and b$_{\alpha}$ a random number in [0, 2$\pi$], generate Gaussian white noise signals and hence they are adequate for simulating Continuous Markov processes. We apply the result to the fluctuation-dissipation formula for the Johnson noise and show that the probability distribution for the long term average of the power of the Johnson noise is a X$^2$ distribution and that the relative error of the long term average is (equation omitted) where N is the number of blocks used in the average.error of the long term average is (equation omitted) where N is the number of blocks used in the average.

표면방전의 집중에 따른 옥외용 설비의 성능평가 (The Estimation of Outdoor Insulation According to the Concentration of Surface Discharge)

  • 임장섭;정승천;이진;노진양
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.212-216
    • /
    • 2001
  • The conventional tracking testing as IEC-60587 is widely used in surface aging measurement of outdoor insulator because those testing can carry out very short time in Lab-testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outdoor HV machine/system. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab-testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, SD occurred from procelain insulator, used 22.9[KV] distribution, is measured with partial temperature distribution in real time, the degradation grade of SD is analyzed through produced patterns in SD concentration according to applied time.

  • PDF

배전용 폴리머 피뢰기의 전기적 특성시험 (Electrical Characteristics Test of Distribution Polymer Lightening Arresters)

  • 권태호;이병성;송일근;김동명;윤태상;정상봉
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.546-549
    • /
    • 2004
  • This paper describes the electrical characteristics of the polymer lightning arresters(L.As) used to protect distribution lines and power facilities from surge. For the relative comparison, the characteristics assessment was done for 2 states of L.As before and after water immersion treatment. The L.As for the comparative test were immersed with water of $95[^{\circ}C]$ considered a severe condition. After the immersion treatment, the assessment was carried out for material analyses in chemical structure(FTIR : fourier transform infrared spectrophotometer). Electrical performance measured insulation resistance measurement, leakage current measurement, critical operation voltage measurement etc.. In addition to, the results were compared with those for the L.As deteriorated in the field. Thus, the accelerative deterioration degree of polymer materials by immersion treatment was evaluated, by which the structural defects of the polymer L.As could be inferred.

  • PDF

적외선방사카메라를 이용한 트래킹열화 온도분포 (Temperature Distribution of Tracking Degradation Using IRR-Camera)

  • 정승천;임장섭;천종철;정우성;이진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.59-63
    • /
    • 2000
  • The conventional tracking testing as IEC-60587 is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outside HV machine. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IIR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, SD occurred from IEC-60587 is measured with partial temperature distribution in real time, the degradation grade of SD is analyzed through produced patterns in IEC-60587 according to applied time.

  • PDF

How the Lender-Borrower Relationship Influences M&As: an Analysis of a Strategic Action in Japan

  • Koo, Ja-Seung
    • 유통과학연구
    • /
    • 제14권8호
    • /
    • pp.93-100
    • /
    • 2016
  • Purpose - This study examines lenders' reactions to M&A, based on the strength of the lender-borrower relationship and the lender's expectations of the potential benefits or risks of the deal. Research design, data, and methodology - This research addresses the lender's influence on the implementation stage of a large-scale strategic action such as M&A to understand the motivation and dynamics of lenders' responses and empirically examines how the lender-borrower relationship influences the focal firm's merger and acquisition (M&A) transactions, using data on 501 M&A deals in Japan from 1990 to 2010. Results - The presented analysis found that lenders that have a strong lender-borrower relationship, especially those showing a high debt equity ratio, support borrowers' M&A progress and the target firm's lenders resist the deal progressing and may raise the acquisition premium if their current power relative to borrowers is weak. Conclusions - Stakeholders including lenders do not favor strategies of focal firms that threaten their future benefits, while they also tend to estimate the potential benefits and losses by comparing their current circumstances with those of other stakeholders. The empirical results of the presented analysis help explain the mechanism of lenders' reactions and offer insights into the power of a closer and stronger lender-borrower relationship.

바이모달 스펙트럼 특성을 가지는 정상확률과정에 대한 다점계류라인의 피로손상도 조합기법 연구 (Fatigue Damage Combination for Spread Mooring System under Stationary Random Process with Bimodal Spectrum Characteristics)

  • 임유창;김경수;정준모
    • 대한조선학회논문집
    • /
    • 제47권6호
    • /
    • pp.813-820
    • /
    • 2010
  • The spread mooring system for FPSO is developed to explore deep sea area, in which swell is dominant. It is known that the tension response of mooring lines in this sea area shows bimodal spectrum. Assuming normal distribution of tension profile and Rayleigh distribution of tension amplitude, the power spectral density function (PSD) of the mooring tension under the bimodal stationary random process is applied for the calculation of spectrum fatigue. Three popular methods, which are simple summation method, combined spectrum method and Jioa-Moan method, are used to combine fatigue damages from bimodal spectrum characteristics. Each damage value is compared with damage using Rainflow Cycle Counting (RCC) method which is believed to be close to exact solution. Vanmarcke' parameter and RMS(Root Mean Square) ratio are employed to assess relative damage variations between from RCC method and from three combination methods. Finally the most reliable fatigue damage combining method for spread mooring system is suggested.

On Testing Exponentiality Against HNRBUE Based on Goodness of Fit

  • Mahmoud, M.A.W.;Diab, L.S.
    • International Journal of Reliability and Applications
    • /
    • 제8권1호
    • /
    • pp.27-39
    • /
    • 2007
  • Based on goodness of fit new testing procedures are derived for testing exponentiality against harmonic new renewal better than used in expectation (HNRBUE). For this aging properties, a nonparametric procedure (U-statistic) is proposed. The percentiles of this test statistic are tabulated for sample sizes n=5(1)30(10)50. The Pitman asymptotic efficiency (PAE) of the test is calculated and compared with, the (PAE) of the test for new renewal better than used (NRBU) class of life distribution [see Mahmoud et al (2003)]. The power of this test is also calculated for some commonly used life distributions in reliability. The right censored data case is also studied. Finally, real examples are given to elucidate the use of the proposed test statistic in the reliability analysis.

  • PDF

적외선 모니터링 관측의 와이블 분포해석 (The Analysis of Weibull Distribution on the Monitoring of IRR Camera)

  • 임장섭;김진국;이학현;이진;이우선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.264-267
    • /
    • 2004
  • The conventional testing as IEC-60587 is widely used in surface aging measurement of outside insulator those testing can carry out very short time in Lab testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of out side HV machine. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab testing method, But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR Camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis.

  • PDF

가상 심장박동 발진기를 활용한 심박변이도 해석 (Interpretation of HRV by the Coupled-Oscillating Cardiac Control System)

  • 정겨운;김정환;이준우;김경섭
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.493-498
    • /
    • 2016
  • Heart Rate Variability (HRV) represents beat-to-beat fluctuations of R-R intervals in Electrocardiogram (ECG). On of the clinical applications of HRV is to assess the mental-stress state by evaluating its power spectral density distribution. This study aims at finding new discriminative role of the coupled-oscillating coupling constants, Cs and Cp in the Integral Pulse Frequency Modulation (IPFM) model. Based on comparing with power spectral density of HRV in terms of the relative ratio of the low and high-frequency power component, we can conclude the fact that the coupling parameters Cs and Cp can replace the role of HRV power spectrum interpretation for judging the mental-stress state.

가공배전선로의 전력설비 감시를 위한 유비쿼터스 센서 (Ubiquitous Sensors for Supervision of Power Facilities in Overhead Power Distribution Lines)

  • 길경석;박대원;김일권;최수연;박찬용
    • 조명전기설비학회논문지
    • /
    • 제21권10호
    • /
    • pp.59-65
    • /
    • 2007
  • 최근 유비쿼터스 센서네트워크 기술이 전력설비관리에 적용되어 오고 있다. 본 연구에서는 가공배전선로에서 전력용변압기와 피뢰기를 관리할 수 있는 유비쿼터스 센서의 설계 및 제작에 대해 기술하였다. 이 센서들은 8-[bit] 마이크로프로세서, IEEE 802.15.4기반 무선통신모듈과 주변 전자회로로 구성되어 있다. 변압기의 부하 및 서지전류 측정에는 1000[A]까지 포화되지 않고 선형성을 유지할 수 있도록 공심형 로고우스키 코일을 제작하여 적용하였다. 피뢰기를 흐르는 $50[{\mu}A]{\sim}1[mA]$의 미소누설전류를 측정하기 위하여 180[Hz]에서 $10^5$의 고투자율을 갖는 영상변류기를 사용하였으며, 피뢰기 감시모듈의 -3[dB] 주파수 대역은 12[Hz]에서 1.24[kHz]이다.