• Title/Summary/Keyword: Relative Power Distribution

Search Result 166, Processing Time 0.024 seconds

A GAUSSIAN WHITE NOISE GENERATOR AND ITS APPLICATION TO THE FLUCTUATION-DISSIPATION FORMULA

  • Moon, Byung-Soo
    • Journal of applied mathematics & informatics
    • /
    • v.15 no.1_2
    • /
    • pp.363-375
    • /
    • 2004
  • In this paper, We show that the bandpass random signals of the form ∑$_{\alpha}$$\alpha$$_{\alpha}$ a Sin(2$\pi$f$_{\alpha}$t + b$_{\alpha}$) where a$_{\alpha}$ being a random number in [0,1], f$_{\alpha}$ a random integer in a given frequency band, and b$_{\alpha}$ a random number in [0, 2$\pi$], generate Gaussian white noise signals and hence they are adequate for simulating Continuous Markov processes. We apply the result to the fluctuation-dissipation formula for the Johnson noise and show that the probability distribution for the long term average of the power of the Johnson noise is a X$^2$ distribution and that the relative error of the long term average is (equation omitted) where N is the number of blocks used in the average.error of the long term average is (equation omitted) where N is the number of blocks used in the average.

The Estimation of Outdoor Insulation According to the Concentration of Surface Discharge (표면방전의 집중에 따른 옥외용 설비의 성능평가)

  • Lim, Jang-Seob;Jeong, Seung-Chun;Lee, Jin;No, Jin-Yang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.212-216
    • /
    • 2001
  • The conventional tracking testing as IEC-60587 is widely used in surface aging measurement of outdoor insulator because those testing can carry out very short time in Lab-testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outdoor HV machine/system. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab-testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, SD occurred from procelain insulator, used 22.9[KV] distribution, is measured with partial temperature distribution in real time, the degradation grade of SD is analyzed through produced patterns in SD concentration according to applied time.

  • PDF

Electrical Characteristics Test of Distribution Polymer Lightening Arresters (배전용 폴리머 피뢰기의 전기적 특성시험)

  • Kwon, Tae-Ho;Lee, Byung-Sung;Song, Il-Keun;Kim, Dong-Myung;Yoon, Tae-Sang;Jung, Sang-Bong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.546-549
    • /
    • 2004
  • This paper describes the electrical characteristics of the polymer lightning arresters(L.As) used to protect distribution lines and power facilities from surge. For the relative comparison, the characteristics assessment was done for 2 states of L.As before and after water immersion treatment. The L.As for the comparative test were immersed with water of $95[^{\circ}C]$ considered a severe condition. After the immersion treatment, the assessment was carried out for material analyses in chemical structure(FTIR : fourier transform infrared spectrophotometer). Electrical performance measured insulation resistance measurement, leakage current measurement, critical operation voltage measurement etc.. In addition to, the results were compared with those for the L.As deteriorated in the field. Thus, the accelerative deterioration degree of polymer materials by immersion treatment was evaluated, by which the structural defects of the polymer L.As could be inferred.

  • PDF

Temperature Distribution of Tracking Degradation Using IRR-Camera (적외선방사카메라를 이용한 트래킹열화 온도분포)

  • Jeong, Seung-Chun;Lim, Jang-Seob;Chen, Jong-Cheol;Jung, Woo-Seong;Lee, Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.59-63
    • /
    • 2000
  • The conventional tracking testing as IEC-60587 is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outside HV machine. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IIR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, SD occurred from IEC-60587 is measured with partial temperature distribution in real time, the degradation grade of SD is analyzed through produced patterns in IEC-60587 according to applied time.

  • PDF

How the Lender-Borrower Relationship Influences M&As: an Analysis of a Strategic Action in Japan

  • Koo, Ja-Seung
    • Journal of Distribution Science
    • /
    • v.14 no.8
    • /
    • pp.93-100
    • /
    • 2016
  • Purpose - This study examines lenders' reactions to M&A, based on the strength of the lender-borrower relationship and the lender's expectations of the potential benefits or risks of the deal. Research design, data, and methodology - This research addresses the lender's influence on the implementation stage of a large-scale strategic action such as M&A to understand the motivation and dynamics of lenders' responses and empirically examines how the lender-borrower relationship influences the focal firm's merger and acquisition (M&A) transactions, using data on 501 M&A deals in Japan from 1990 to 2010. Results - The presented analysis found that lenders that have a strong lender-borrower relationship, especially those showing a high debt equity ratio, support borrowers' M&A progress and the target firm's lenders resist the deal progressing and may raise the acquisition premium if their current power relative to borrowers is weak. Conclusions - Stakeholders including lenders do not favor strategies of focal firms that threaten their future benefits, while they also tend to estimate the potential benefits and losses by comparing their current circumstances with those of other stakeholders. The empirical results of the presented analysis help explain the mechanism of lenders' reactions and offer insights into the power of a closer and stronger lender-borrower relationship.

Fatigue Damage Combination for Spread Mooring System under Stationary Random Process with Bimodal Spectrum Characteristics (바이모달 스펙트럼 특성을 가지는 정상확률과정에 대한 다점계류라인의 피로손상도 조합기법 연구)

  • Lim, Yu-Chang;Kim, Kyung-Su;Choung, Joon-Mo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.6
    • /
    • pp.813-820
    • /
    • 2010
  • The spread mooring system for FPSO is developed to explore deep sea area, in which swell is dominant. It is known that the tension response of mooring lines in this sea area shows bimodal spectrum. Assuming normal distribution of tension profile and Rayleigh distribution of tension amplitude, the power spectral density function (PSD) of the mooring tension under the bimodal stationary random process is applied for the calculation of spectrum fatigue. Three popular methods, which are simple summation method, combined spectrum method and Jioa-Moan method, are used to combine fatigue damages from bimodal spectrum characteristics. Each damage value is compared with damage using Rainflow Cycle Counting (RCC) method which is believed to be close to exact solution. Vanmarcke' parameter and RMS(Root Mean Square) ratio are employed to assess relative damage variations between from RCC method and from three combination methods. Finally the most reliable fatigue damage combining method for spread mooring system is suggested.

On Testing Exponentiality Against HNRBUE Based on Goodness of Fit

  • Mahmoud, M.A.W.;Diab, L.S.
    • International Journal of Reliability and Applications
    • /
    • v.8 no.1
    • /
    • pp.27-39
    • /
    • 2007
  • Based on goodness of fit new testing procedures are derived for testing exponentiality against harmonic new renewal better than used in expectation (HNRBUE). For this aging properties, a nonparametric procedure (U-statistic) is proposed. The percentiles of this test statistic are tabulated for sample sizes n=5(1)30(10)50. The Pitman asymptotic efficiency (PAE) of the test is calculated and compared with, the (PAE) of the test for new renewal better than used (NRBU) class of life distribution [see Mahmoud et al (2003)]. The power of this test is also calculated for some commonly used life distributions in reliability. The right censored data case is also studied. Finally, real examples are given to elucidate the use of the proposed test statistic in the reliability analysis.

  • PDF

The Analysis of Weibull Distribution on the Monitoring of IRR Camera (적외선 모니터링 관측의 와이블 분포해석)

  • Lim, Jang-Seob;Kim, Jin-Gook;Lee, Hack-Hyun;Lee, Jin;Lee, Woo-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.264-267
    • /
    • 2004
  • The conventional testing as IEC-60587 is widely used in surface aging measurement of outside insulator those testing can carry out very short time in Lab testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of out side HV machine. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab testing method, But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR Camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis.

  • PDF

Interpretation of HRV by the Coupled-Oscillating Cardiac Control System (가상 심장박동 발진기를 활용한 심박변이도 해석)

  • Jeung, Gyeo-Wun;Kim, Jeong-Hwan;Lee, Jun-Woo;Kim, Kyeong-Seop
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.3
    • /
    • pp.493-498
    • /
    • 2016
  • Heart Rate Variability (HRV) represents beat-to-beat fluctuations of R-R intervals in Electrocardiogram (ECG). On of the clinical applications of HRV is to assess the mental-stress state by evaluating its power spectral density distribution. This study aims at finding new discriminative role of the coupled-oscillating coupling constants, Cs and Cp in the Integral Pulse Frequency Modulation (IPFM) model. Based on comparing with power spectral density of HRV in terms of the relative ratio of the low and high-frequency power component, we can conclude the fact that the coupling parameters Cs and Cp can replace the role of HRV power spectrum interpretation for judging the mental-stress state.

Ubiquitous Sensors for Supervision of Power Facilities in Overhead Power Distribution Lines (가공배전선로의 전력설비 감시를 위한 유비쿼터스 센서)

  • Kil, Gyung-Suk;Park, Dae-Won;Kim, Il-Kwon;Choi, Su-Yeon;Park, Chan-Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.59-65
    • /
    • 2007
  • Recently, ubiquitous sensor network(USN) techniques have been applied to electric power facility management. This paper dealt with the designed and fabricated ubiquitous sensors which monitor transformers and lightning arresters installed in overhead distribution systems. The sensors consist of a 8-[bit] microprocessor unit, a wireless communication nodule specified in IEEE 802.15.4, and associated electronics. A Rogowski coil was fabricated to measure load of transformer and surge current without saturation having good linearity up to 1000[A]. A zero-phase current transformer with a high relative permeability of $10^5$ at 180[Hz] was used to detect small leakage current of $50[{\mu}A]{\sim}1[mA]$ flowing lightning arrester, and the frequency bandwidth of the module is ranges from 12[Hz] to 1.24[kHz] at -3[dB].