• Title/Summary/Keyword: Relative Position

Search Result 1,253, Processing Time 0.02 seconds

A Method for Real Time Target Following of a Mobile Robot Using Heading and Distance Information (방향각 및 거리 정보에 의한 이동 로봇의 실시간 목표물 추종 방법)

  • Ko, Nak-Yong;Seo, Dong-Jin;Moon, Yong-Seon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.18 no.5
    • /
    • pp.624-631
    • /
    • 2008
  • This paper presents a method for a mobile robot to follow a moving object in real time. The robot follows a target object keeping the facing angle toward the target and the distance to the target to given value. The method consists of two procedures: first, the detection of target position in the robot coordinate system, and the second, the calculation of translational velocity and rotational velocity to follow the object:. To detect the target location, range sensor data is represented in histogram. Based on the real time calculation of the location of the target relative to the robot, translational velocity and rotational velocity to follow the target are calculated. The velocities make the heading angle and the distance to target converge toward the desired ones. The performance of the method is tested through simulation. In the simulation, the target moves with three different trajectories, straight line trajectory, rectangular trajectory, and circular trajectory. As shown in the results, it is inevitable to lose track temporarily of the target when the target suddenly changes its motion direction. Nevertheless, the robot speeds up to catch up and finally succeeds to follow the target as soon as possible even in this case. The proposed method can also be utilized to coordinate the motion of multiple robots to keep their formation as well as to follow a target.

Relationship between disease stage and renal function in bisphosphonate-related osteonecrosis of the jaw

  • Kim, Yun-Ho;Park, Han-Kyul;Choi, Na-Rae;Kim, Seong-Won;Kim, Gyoo-Cheon;Hwang, Dae-Seok;Kim, Yong-Deok;Shin, Sang-Hun;Kim, Uk-Kyu
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.1
    • /
    • pp.16-22
    • /
    • 2017
  • Objectives: Bisphosphonate is the primary cause of bisphosphonate-related osteonecrosis of the jaw (BRONJ). Bisphosphonates are eliminated from the human body by the kidneys. It is anticipated that bisphosphonate levels in the body will increase if the kidney is in a weak state or if there is systemic disease that affects kidney function. The aim of this study was to analyze the relevance of renal function in the severity of BRONJ. Materials and Methods: Ninety-three patients diagnosed with BRONJ in Pusan National University Dental Hospital from January 2012 to December 2014 were included in this study. All patients underwent a clinical exam, radiographs, and serologic lab test, including urine analysis. The patient's medical history was also taken, including the type of bisphosphonate drug, the duration of administration and drug holiday, route of administration, and other systemic diseases. In accordance with the guidelines of the 2009 position paper of American Association of Oral and Maxillofacial Surgeons, the BRONJ stage was divided into 4 groups, from stage 0 to 3, according to the severity of disease. IBM SPSS Statistics version 21.0 (IBM Co., USA) was used to perform regression analysis with a 0.05% significance level. Results: BRONJ stage and renal factor (estimated glomerular filtration rate) showed a moderate statistically significant correlation. In the group with higher BRONJ stage, the creatinine level was higher, but the increase was not statistically significant. Other factors showed no significant correlation with BRONJ stage. There was a high statistically significant correlation between BRONJ stage and 'responder group' and 'non-responder group,' but there was no significant difference with the 'worsened group.' In addition, the age of the patients was a relative factor with BRONJ stage. Conclusion: With older age and lower renal function, BRONJ is more severe, and there may be a decrease in patient response to treatment.

Application of an imaging plate to relative dosimetry of clinical x-ray beams (Imaging Plate를 이용한 의료용 광자선의 선량측정)

  • 임상욱;여인환;김대용;안용찬;허승재;윤병수
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.117-122
    • /
    • 2000
  • The IP(imaging plate) has been widely used to measure the two-dimensional distribution of incident radiation since it has a high sensitivity, reusability, a wide dynamic range, a high position resolution. Particularly, the easiness of acquiring digitized image using IP poses a strong merit because recent trend of data handling prefers image digitization. In order to test its usefulness in photon beam dosimetry, we measured the off-axis ratio(OAR) on portal planes and percent depth dose(PDD) within a phantom using IP, and compared the results with the data based on EGS4 Monte Carlo particle transport code, ion-chambers, conventional films. For the measurement, we used 6 MV X-rays, various field sizes. As a result, IP showed significant deviation from ion-chamber measurement: a significant overresponse, 100% greater than that of ion-chamber measurement at deep part of the phantom. Filtration of low-energy scattered photons at deep part of the phantom using 0.5 mm thick lead sheets did improve the result, only to the unacceptable extent. However, portal dose measurement showed possibilities of If as a dosimeter by showing errors less than 5%, as compared with film measurement.

  • PDF

Safety Simulation of Therapeutic I-131 Capsule Using GEANT4 (GEANT4를 이용한 치료용 I-131 캡슐의 안정성 시뮬레이션)

  • Jeong, Yeong-Hwan;Kim, Byung-Cheol;Sim, Cheol-Min;Seo, Han-Kyung;Gwon, Yong-Ju;Han, Dong-Hyun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.57-61
    • /
    • 2014
  • Purpose Iodine (I-131) is one of the most widely used radioactive isotopes for therapeutic in the field of nuclear medicine. Therapeutic I-131 capsule is made out of lead to shield high energy radiation. Accurate dosimetry is necessarily required to perform safe and effective work for relative workers. The Monte Carlo method is known as a method to predict the absorbed dose distribution most accurately in radiation therapy and many researchers constantly attempt to apply this method to the dose calculation of radiotherapy recently. This paper aims to calculate distance dependent and activity dependent therapeutic I-131 capsule using GEANT4. Materials and Methods Therapeutic capsules was implemented on the basis of the design drawings. The simulated dose was determined by generating of gamma rays of energy to more than 364 keV. The simulated dose from the capsule at the distance of 10 cm and 100 cm was measured and calculated in the model of water phantom. The simulated dose were separately calculated for each position of each detector. Results According to the domestic regulation on radiation safety, the dose at 10 cm and 100 cm away from the surface of therapeutic I-131 capsule should not exceed 2.0 mSv/h and 0.02 mSv/h, respectively. The simulated doses turned out to be less than the limit, satisfying the domestic regulation. Conclusion These simulation results may serve as useful data in the prediction of hands dose absorbed by I-131 capsule handling. GEANT4 is considered that it will be effectively used in order to check the radiation dose.

  • PDF

Application and Evaluation of ITS Map Datum and Location Referencing System for ITS User Services (ITS서비스를 위한 Map Datum 및 위치참조체계 모델의 적용 및 평가)

  • 최기주;이광섭
    • Journal of Korean Society of Transportation
    • /
    • v.17 no.2
    • /
    • pp.55-68
    • /
    • 1999
  • Many ITS services require map databases in digital form to meet desired needs. Due to the dynamic nature of ITS and the sheer diversity of applications, the design and development of spatial databases to meet those needs pose a major challenge to both the public and private sectors. This challenge is further complicated by the necessity to transfer locationally referenced information between different kinds of databases and spatial data handling systems so that ITS products will work seamlessly across the region and nation. The Purpose of this paper is to develop the framework-models commonly to reference locations in the various applications and systems-the ITS Map Datum and LRS(Location Referencing System). The ITS Map Datum consists of the around control points which are the prime intersections (nodes) of the nationwide road network In this study, the major points have been determined along wish link-node modeling procedure. LRS, defined as a system for determining the position (location) of an entity relative to other entities or to some external frame of reference, has also been set up using CSOM type method. The method has been implemented using ArcView GIS software over the Kangnam and Seocho districts in the city of Seoul, showing that the implemented LRS scheme can be used successfully elsewhere. With the proper advent of the K.ITS architecture and services, the procedure can be used to improve the data sharing and to inter operate among systems, enhancing the efficiency both in terms of money and time.

  • PDF

Wavelet based video coding with spatial band coding (대역별 공간 부호화를 이용한 웨이블릿 기반 동영상 부호화)

  • Park, Min-Seon;Park, Sang-Ju
    • The KIPS Transactions:PartB
    • /
    • v.9B no.3
    • /
    • pp.351-358
    • /
    • 2002
  • Video compression based on DCT (Discrete Cosine Transform) has weakpoints of blocking artifacts and pixel loss when the resolution is changed. DWT (Discrete Wavelet Transform) based method can overcome such problems. In SAMCoW (Scalable Adaptive Motion Compensation Wavelet), one of wavelet based video coding algorithm, both intra frames and motion compensated error frames are encoded using EZW(Embedded Zerotree Wavelet) algorithm. However the property of wavelets transform coefficients of motion compensated error frames are different from that of still images. Signal energy is not highly concentrated in the lower bands which is true for most still image cases. Signal energy is rather evenly distributed over all frequency bands. This paper suggests a new video coding algorithm utilizing these properties. Spatial band coding which is known to be very effective for encoding images with relative1y high frequency components and not utilizing the interband coefficients correlation is applied instead of EZW to encode both intra and inter frames. In spatial band coding, the position and value of significant wavelet coefficients in each band are progressively transmitted. Unlike EZW, inter band coefficients correlations are not utilized in spatial band coding. It has been shown that spatial band coding gives better performance than EZW when applied to wavelet based video compression.

Automatic Extraction of Ascending Aorta and Ostium in Cardiac CT Angiography Images (심장 CT 혈관 조영 영상에서 대동맥 및 심문 자동 검출)

  • Kim, Hye-Ryun;Kang, Mi-Sun;Kim, Myoung-Hee
    • Journal of the Korea Computer Graphics Society
    • /
    • v.23 no.1
    • /
    • pp.49-55
    • /
    • 2017
  • Computed tomographic angiography (CTA) is widely used in the diagnosis and treatment of coronary artery disease because it shows not only the whole anatomical structure of the cardiovascular three-dimensionally but also provides information on the lesion and type of plaque. However, due to the large size of the image, there is a limitation in manually extracting coronary arteries, and related researches are performed to automatically extract coronary arteries accurately. As the coronary artery originate from the ascending aorta, the ascending aorta and ostium should be detected to extract the coronary tree accurately. In this paper, we propose an automatic segmentation for the ostium as a starting structure of coronary artery in CTA. First, the region of the ascending aorta is initially detected by using Hough circle transform based on the relative position and size of the ascending aorta. Second, the volume of interest is defined to reduce the search range based on the initial area. Third, the refined ascending aorta is segmented by using a two-dimensional geodesic active contour. Finally, the two ostia are detected within the region of the refined ascending aorta. For the evaluation of our method, we measured the Euclidean distance between the result and the ground truths annotated manually by medical experts in 20 CTA images. The experimental results showed that the ostia were accurately detected.

A Study on Recognition of Both of PCA and LAD Using Types of Vehicle Plate (PCA와 LDA을 이용한 차량 번호판 통합 인식에 관한 연구)

  • Lee, Jin-Ki;Kim, Hyun-Yul;Lee, Seung-Kyu;Lee, Geon-Wha;Park, Yung-Rok;An, Ki-Nam;Bae, Cheol-Su;Park, Young-Cheol
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.6 no.1
    • /
    • pp.6-17
    • /
    • 2013
  • Recently, the color of vehicle license plate has been changed from green to white. Thus the vehicle plate recognition system used for parking management systems, speed and signal violation detection systems should be robust to the both colors. This paper presents a vehicle license plate recognition system, which works on both of green and white plate at the same time. In the proposed system, the image of license plate is taken from a captured vehicle image by using morphological information. In the next, each character region in the license plate image is extracted based on the vertical and horizontal projection of plate image and the relative position of individual characters. Finally, for the recognition process of extracted characters, PCA(Principal Component Analysis) and LDA(Linear Discriminant Analysis) are sequentially utilized. In the experiment, vehicle license plates of both green background and white background captured under irregular illumination conditions have been tested, and the relatively high extraction and recognition rates are observed.

Acceptance Testing and Commissioning of Robotic Intensity-Modulated Radiation Therapy M6 System Equipped with InCiseTM2 Multileaf Collimator

  • Yoon, Jeongmin;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • Progress in Medical Physics
    • /
    • v.29 no.1
    • /
    • pp.8-15
    • /
    • 2018
  • This work reports the acceptance testing and commissioning experience of the Robotic Intensity-Modulated Radiation Therapy (IMRT) M6 system with a newly released $InCise^{TM}2$ Multileaf Collimator (MLC) installed at the Yonsei Cancer Center. Acceptance testing included a mechanical interdigitation test, leaf positional accuracy, leakage check, and End-to-End (E2E) tests. Beam data measurements included tissue-phantom ratios (TPRs), off-center ratios (OCRs), output factors collected at 11 field sizes (the smallest field size was $7.6mm{\times}7.7mm$ and largest field size was $115.0mm{\times}100.1mm$ at 800 mm source-to-axis distance), and open beam profiles. The beam model was verified by checking patient-specific quality assurance (QA) in four fiducial-inserted phantoms, using 10 intracranial and extracranial patient plans. All measurements for acceptance testing satisfied manufacturing specifications. Mean leaf position offsets using the Garden Fence test were found to be $0.01{\pm}0.06mm$ and $0.07{\pm}0.05mm$ for X1 and X2 leaf banks, respectively. Maximum and average leaf leakages were 0.20% and 0.18%, respectively. E2E tests for five tracking modes showed 0.26 mm (6D Skull), 0.3 mm (Fiducial), 0.26 mm (Xsight Spine), 0.62 mm (Xsight Lung), and 0.6 mm (Synchrony). TPRs, OCRs, output factors, and open beams measured under various conditions agreed with composite data provided from the manufacturer to within 2%. Patient-specific QA results were evaluated in two ways. Point dose measurements with an ion chamber were all within the 5% absolute-dose agreement, and relative-dose measurements using an array ion chamber detector all satisfied the 3%/3 mm gamma criterion for more than 90% of the measurement points. The Robotic IMRT M6 system equipped with the $InCise^{TM}2$ MLC was proven to be accurate and reliable.

Observations on the Coastal Ocean Response to Typhoon Maemi at the East Sea Real-time Ocean Buoy (동해 실시간 해양관측 부이로부터 관측한 태풍 매미에 대한 연안해양의 반응 고찰)

  • Nam, Sung-Hyun;Yun, Jae-Yul;Kim, Kuh
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.9 no.3
    • /
    • pp.111-118
    • /
    • 2004
  • An ocean buoy was deployed 10 km off Donghae city, Korea at a depth of 130 m to measure meteorological (air pressure, air temperature, wind speed, wind gust, wind direction, relative humidity) and oceanographic data (water properties and currents in the whole column) in real-time. The buoy recorded a maximum wind gust of 25 m/s (10 minutes' average speed of 20 m/s) and a minimum air pressure of 980 hPa when the eye of typhoon Maemi passed by near the Uljin city, Korea at 03:00 on 13 September 2003. The wave height reached maximum of 9 m with the significant wave height of 4 m at 04:00 (1 hour after the passage of Maemi). The currents measured near the surface reached up to about 100 cm/s at 13:00 (10 hours after the passage of Maemi). The mixed layer (high temperature and low salinity) thickness, which was accompanied by strong southward current, gradually increased from 20 m to 40 m during the 10 hours. A simple two layer model for the response to an impulsive alongshore wind over an uniformly sloping bottom developed by Csanady (1984) showed reasonable estimates of alongshore and offshore currents and interface displacement for the condition of typhoon Maemi at the buoy position (x=8.15 km) during the 10 hours.