• Title/Summary/Keyword: Relative Measurement

Search Result 1,637, Processing Time 0.034 seconds

Assessment of efficacy of respiration monitoring system customized for patients under critical care (위급 중환자에 특화된 호흡 모니터링 시스템의 유효성 평가)

  • Lee, In-kwang;Park, Mi-Jung;Kim, Kyoung-Oak;Cha, Eun-Jong;Kim, Kyung-Ah
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1431-1432
    • /
    • 2015
  • A system was developed to continuously monitor the respiratory signal under critical care, followed by performance evaluation for clinical application. Very much accurate pressure measurement was made in the endo-tracheal tube with mean relative error of 0.13%. In the comparative experiment simulating inspiration and expiration, the tidal volume measurement was also accurate within mean relative error of 3%, validating reliable measurement of respiratory signals.

  • PDF

Analysis of the Relative Effect of Rebar and Electrode Arrangement in the Measurement of Spparent Resistivity (겉보기 비저항 측정에서 철근과 전극배치의 상대적 영향 분석)

  • Lim, Young-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.317-318
    • /
    • 2021
  • The effect of reinforcing bars embedded in concrete varies depending on the position of the electrode in the electrical resistivity measurement. In this study, the apparent resistivity according to the electrode arrangement is analyzed for each measurement angle. Through this, it is intended to be used to improve the accuracy of measurement in the concrete resistivity.

  • PDF

A Study on relative distance estimation for asynchronous FDD using Two-way ToA (비동기식 FDD에서 Two-way ToA를 통한 상대거리 측정에 관한 연구)

  • Song, Young-Hwan;Park, Jae-Soo;Shin, Young-Jun;Yoon, Chang-Bae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.12
    • /
    • pp.1175-1186
    • /
    • 2016
  • The relative distance estimation technique is important to Location-Based Service(: LBS) in a wireless communication environment. In this paper, we propose a scheme for measuring the relative distance by utilizing a frame structure of a physical layer in asynchronous Frequency Division Duplexing(: FDD) when the Internal and external infrastructure for position measurement cannot be used. The proposed method is suitable for continuous distance measurement. The test results showed that the proposed method has the accuracy of less than 10 meters on average.

Development of Relative Calibration Method for Measurement of Radon and Application (라돈농도 측정을 위한 고체비적검출기의 상대교정법 개발 및 응용)

  • Park, Young-Woong;Yang, Hyun-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.4
    • /
    • pp.243-250
    • /
    • 1997
  • A relative-calibration-method of solid-state-track-detector for measurement of radon in air has been developed, and the concentration of radon in each room of a 15th-floor-apartment was measured by using the relative calibrated SSTD. There is a tendency to decrease the concentration of radon when the floor is higher, but the main factor to reduce the concentration of radon in room appeared to be ventilation rate. Average concentration of radon of the 15th-floor-apartment was $1.50{\pm}0.51pCi/l$, and the highest and the lowest concentration of radon were $2.68{\pm}0.32pCi/l$, $0.69{\pm}0.16pCi/l$ respectively.

  • PDF

Measurement of the Relative Phase Fluctuation by Multiport-Homodyne Detection Method (Multiport-Homodyne 측정 방법에 의한 광신호의 상대적 위상 변화에 대한 연구)

  • 최준홍
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.02a
    • /
    • pp.242-247
    • /
    • 1990
  • By self-homodyne method we measured the relative phase fluctuation of a light wave. Balanced detection system can eliminate local oscillator excess noise and multiport detection makes it possible ot measure the phase change of the signal beam. Deriving the SB(Signal Beam) and the LO(Local Oscillator) from the same laser source, we find the SB maintain constant phase relative to that of the LO. We have introduced a phase fluctuation in the SB by modulating the beam path of the SB. The measured phase fluctuation agreed well with the predicted one, thereby we confirmed the reliability of our system.

  • PDF

Identification of Geotechnical Paramters Using Relative Convergence Measurements (상대변위를 이용한 지반정수 인식)

  • Choi, Sang-Hyun;Cho, Kook-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.418-423
    • /
    • 2005
  • In designing underground structure such as tunnels, estimating geotechnical characteristics of the ground is one of the most important and difficult tasks. In this paper, a methodology that can identify geotechnical parameters using only field-measured relative convergence displacements is presented. By using only relative convergence measurement data, inevitable errors in absolute convergence estimation can be avoided and in turn the parameter estimation process can be simplified. The methodology utilizes sensitivity relationship between static displacement measurements and geotechnical parameters. The feasibility and applicability of the proposed methodology is verified via a 3-d numerical example of a tunnel structure.

  • PDF

A Experimental Study on Application of KS F 2456 using Shear Wave (급속 동결 융해에 대한 콘크리트의 저항 시험방법(KS F 2456)에 전단파 적용을 위한 실험적 연구)

  • An, Ji-Hwan;Jeon, Sung-Il;Kwon, Soo-Ahn
    • International Journal of Highway Engineering
    • /
    • v.14 no.5
    • /
    • pp.57-65
    • /
    • 2012
  • PURPOSES: It is important to consider the long-term performance of concrete pavement, because concrete pavement is more exposed to the various environmental conditions than any other concrete structures. One of the several methods to evaluate the long-term performance of concrete during winter is KS F 2456. Relative dynamic modulus of elasticity shows the resistance to freezing and thawing. METHODS: To measure relative dynamic modulus of elasticity, ultra sonic is generally used. But in this study, to measure the relative dynamic modulus of elasticity, both ultra sonic and shear wave were used and then compared each other. RESULTS: The results from the measurement by ultrasonic wave and shear wave were divided into three types. Type 1 : Specimens are good and relative dynamic modulus of elasticity did not decrease until 300 cycle. Type 2 : The relative dynamic modulus of elasticity decreased from the late cycle.(about 150 cycle later) Type 3 : The relative dynamic modulus of elasticity consistently decreased from the beginning. As a result of ANOVA, there is no difference according to measuring method, in type 2 and 3. But there is a difference according to measuring method, in type 1's relative dynamic modulus of elasticity. CONCLUSIONS: It is proved that shear wave can be used to understand the damage tendency of relative freezing and thawing and to measure the relative dynamic modulus of elasticity.

Error Analysis for Microwave Permittivity Measurement using Post Resonator Method (Post Resonator 방법에 의한 마이크로파 유전율 측정에서의 오차 분석)

  • Cho, Mun-Seong;Lim, Donggun;Park, Jae-Hwan;Park, Jae-Gwan
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.19 no.3
    • /
    • pp.43-48
    • /
    • 2012
  • Errors of relative permittivity calculation caused by the variation of sample aspect ratio (diameter/height) and measuring geometry were analyzed by computer simulation and measurement. Firstly, the $S_{21}$ spectrum of the sample (permittivity 38) was simulated in the post resonator measuring apparatus by HFSS simulation. Then, the relative permittivity was calculated from the $TE_{011}$ mode resonant frequency. The relative permittivity varied by ca. 0.3% with sample aspect ratio variation (D/H=0.8~1.6). The relative permittivity varied by ca. 1~10% when the 1~10% of air-gap was introduced in between the dielectric disk and upper conductor. All the simulation results showed consistent tendency with real measurement.

Measurement Method of Noise Correlation Matrix Using Relative Noise Ratio (상대적인 잡음비를 이용한 잡음상관행렬 측정방법)

  • Lee, Dong-Hyun;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.5
    • /
    • pp.430-437
    • /
    • 2016
  • In general, noise measurement results show larger random ripple than those of the network analyzer. The reason for the lager random ripple of the noise measurements is considered that the general noise measurements uses absolute measured noise powers, while the network analyzer measures using a ratio of the measured powers. In this paper, a novel measurement method of noise correlation matrix using relative noise ratios is proposed. Proposed method measures the five noise powers of DUT for the five input impedance variations and the four relative noise ratios are formed using the five measured noise powers. The four noise ratios are used to compute the noise correlation matrix and noise parameters. The resulting noise parameters for a 0.5 dB attenuator show good agreements with theoretical values calculated by S-parameters. Also, the noise parameters of an active DUT with a noise figure of less than 1 dB are measured and the measured results show a small random ripple as expected and their values are physically acceptable. In conclusion, the proposed method can be applied to the noise parameter measurements for DUT with a noise figure below 1 dB.

Limitation of Measurement System in Application of Angular Distortion Criterion to Structure Near Road Embankment (도로 성토 시 인근 구조물에 각변위기준 적용에 있어 계측시스템의 한계성)

  • Kim, Taehyung;Kim, Dongin;Kim, Yuntae;You, Sangho;Jung, Youngeun;Kim, Sungwoung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.1
    • /
    • pp.43-51
    • /
    • 2014
  • Angular distortion due to differential settlement is one of the critical factors which influences on the stability and serviceability of a structure. The angular distortion criterion proposed by Bjerrum is generally used in practice. However, the measurement system used in field especially a road embankment site did not properly represent the angular distortion of a structure. The problem was related to the shortage and not proper installation of measurement gauges, and the incorrect understanding of the basic concept of angular distortion in interpretation of measurement data. These things were reveled by analyzing the measured data in the road embankment site. An improved measurement system has been suggested as a so-called "relative displacement measurement system" between columns with automatic measurement.