• Title/Summary/Keyword: Relative Interval

Search Result 377, Processing Time 0.026 seconds

An analysis of the worst performance index in the interval system (구간 시스템의 최대평가함수 해석)

  • 김우성;김석우;김영철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.984-987
    • /
    • 1996
  • We consider a feedback control system including interval plant where uncertain parameters expressed in the hyperrectangular box X. Here we define the maximum value of the integral of the error(ISE) as the worst performance index(WPI) due to the plant parameter uncertainty. Suppose that the closed loop system retains robust stability and it belongs to type I. Then we show that the WPI occurs only on the exposed edges of Q. In particular, it is also shown that if ISE is a convex function relative to X, the WPI is attained at one of vertices of X. Some examples are given.

  • PDF

A Numerical analysis on the pressure drop of the flow field past a two-staged orifice in a rectangular duct (사각덕트 내 이단 오리피스를 지나는 유동의 압력강하에 대한 수치해석)

  • Song, Woo-Yeol;Kim, You-Gon
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2747-2752
    • /
    • 2007
  • A numerical study has been performed on the flow past a two-staged orifice in a rectangular duct. The flow field including the recirculation region behind the orifice was investigated and the pressure drop was calculated. Water was used as a working fluid and the flow was treated as the turbulent flow, of which the Raynolds number was 6000. The main parameters for the pressure drop and the recirculation region were the orifice's inclined angle against the duct, the interval between two orifices, the shape of the orifice's hole having the same area, and the change of the hole position at the same interval. The variation of the flow field was investigated with each parameter. Consequently, it was found that the most dominant parameter influencing the drop of the pressure was the change of the hole position at the same interval between orifices. Especially when the interval between orifices was narrow and the relative position the holes was changed, its effect to the flow field was shown most drastically as a result of this study. The SIMPLER algorithm with FLUENT code was employed to analyze the flow field.

  • PDF

Generation of high cadence SDO/AIA images using a video frame interpolation method, SuperSloMo

  • Sung, Suk-Kyung;Shin, Seungheon;Kim, TaeYoung;Lee, Jin-Yi;Park, Eunsu;Moon, Yong-Jae;Kim, Il-Hoon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.44.1-44.1
    • /
    • 2019
  • We generate new intermediate images between observed consecutive solar images using NVIDIA's SuperSloMo that is a novel video interpolation method. This technique creates intermediate frames between two successive frames to form a coherent video sequence for both spatially and temporally. By using SuperSloMo, we create 600 images (12-second interval) using the observed 121 SDO/AIA 304 Å images (1-minute interval) of a filament eruption event on December 3, 2012. We compare the generated images with the original 12-second images. For the generated 480 images the correlation coefficient (CC), the relative error (R1), and the normalized mean square error (R2) are 0.99, 0.40, and 0.86, respectively. We construct a video made of the generated images and find a smoother erupting movement. In addition, we generate nonexistent 2.4-second interval images using the original 12-second interval images, showing slow motions in the eruption. We will discuss possible applications of this method.

  • PDF

Derivation of Optimal Design Flood by Gamma and Generalized Gamma Distribution Models(I) - On the Gamma Distribution Models - (Gamma 및 Generalized Gamma 분포 모형에 의한 적정 설계홍수량의 유도 (I) -Gamma 분포 모형을 중심으로-)

  • 이순혁;박명근;정연수;맹승진;류경식
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.3
    • /
    • pp.83-95
    • /
    • 1997
  • This study was conducted to derive optimal design floods by Gamma distribution models of the annual maximum series at eight watersheds along Geum , Yeong San and Seom Jin river Systems, Design floods obtained by different methods for evaluation of parameters and for plotting positions in the Gamma distribution models were compared by the relative mean errors and graphical fit along with 95% confidence interval plotted on Gamma probability paper. The results were analyzed and summarized as follows. 1.Adequacy for the analysis of flood flow data used in this study was confirmed by the tests of Independence, Homogeneity and detection of Outliers. 2.Basic statistics and parameters were calculated by Gamma distribution models using Methods of Moments and Maximum Likelihood. 3.It was found that design floods derived by the method of maximum likelihood and Hazen plotting position formular of two parameter Gamma distribution are much closer to those of the observed data in comparison with those obtained by other methods for parameters and for plotting positions from the viewpoint of relative mean errors. 4.Reliability of derived design floods by both maximum likelihood and method of moments with two parameter Gamma distribution was acknowledged within 95% confidence interval.

  • PDF

Effect of humidity on postmortem changes in rats

  • Seroc Oh;Byeongwoo Ahn;Beom Jun Lee;Sang-Yoon Nam
    • Journal of Veterinary Science
    • /
    • v.25 no.3
    • /
    • pp.24.1-24.9
    • /
    • 2024
  • Importance: In veterinary forensic science, accurately determining the postmortem interval (PMI) is crucial for identifying the causes of animal deaths. Autolysis, a significant postmortem process, influences PMI estimation, but its relationship with humidity is not well understood. Objective: This study aimed to improve the accuracy of PMI estimates in veterinary forensic cases by looking into how different humidity levels affect autolysis in different organs of rats. Methods: The study involved 38 male rats, examining histopathological changes in their heart, liver, and pancreas. These organs were subjected to controlled humidity levels (20%, 55%, and 80%) at a constant 22℃. Tissue samples were collected at several intervals (0 h, 12 h, 24 h, 3 days, and 8 days) for comprehensive analysis. Results: Distinct autolytic characteristics in animal organs emerged under varying humidity conditions. The low-humidity environment rapidly activated autolysis more than the high-humidity environment. In addition, it was found that lower humidity caused nuclear pyknosis, cytoplasmic disintegration, and myofiber interruption. The liver, in particular, showed portal triad aggregation and hepatocyte individuation. The pancreas experienced cell fragmentation and an enlarged intracellular space. High humidity also caused the loss of striations in cardiac tissues, and the liver showed vacuolation. Under these conditions, the pancreas changed eosinophilic secretory granules. Conclusions and Relevance: The study successfully established a clear connection between the autolytic process in PMIs and relative humidity. These findings are significant for developing a more accurate and predictable method for PMI estimation in the field of veterinary forensic science.

Asymptotic Relative Efficiency of Chi-squared Type Tests Based on the Empirical Process

  • Lee, Sang-Yeol
    • Journal of the Korean Statistical Society
    • /
    • v.25 no.3
    • /
    • pp.337-346
    • /
    • 1996
  • The chi-squared type statistic generated from the empirical process can be used for testing the goodness of fit hypothesis on iid random sample. Lee (1995) showed that under some conditions, the chi-squared type statistic is asymptotically maximin in the sense of Strasser (1985). Since the chi-squared type statistic depends on the choice of *points in the unit interval, it is worth investigating the points yielding more efficient tests. Motivated by this viewpoint, we are led to study the asymptotic relative efficiency of chi-squared type tests in the same setting of Lee (1995). Some examples are given for illustration.

  • PDF

Similarity Measurement Using Open-Ball Scheme for 2D Patterns in Comparison with Moment Invariant Method (Open-Ball Scheme을 이용한 2D 패턴의 상대적 닮음 정도 측정의 Moment Invariant Method와의 비교)

  • Kim, Seong-Su
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.1
    • /
    • pp.76-81
    • /
    • 1999
  • The degree of relative similarity between 2D patterns is obtained using Open-Ball Scheme. Open-Ball Scheme employs a method of transforming the geometrical information on 3D objects or 2D patterns into the features to measure the relative similarity for object(patten) recognition, with invariance on scale, rotation, and translation. The feature of an object is used to obtain the relative similarity and mapped into [0, 1] the interval of real line. For decades, Moment-Invariant Method has been used as one of the excellent methods for pattern classification and object recognition. Open-Ball Scheme uses the geometrical structure of patterns while Moment Invariant Method uses the statistical characteristics. Open-Ball Scheme is compared to Moment Invariant Method with respect to the way that it interprets two-dimensional patten classification, especially the paradigms are compared by the degree of closeness to human's intuitive understanding. Finally the effectiveness of the proposed Open-Ball Scheme is illustrated through simulations.

  • PDF

Relative ratio about dose value of thermoluminescence and optical stimulated luminescence dosimeter according to exposed condition in diagnostic radiation (진단방사선의 노출 조건에 따른 열형광선량계와 광자극형광 선량계의 선량값 상대비)

  • Kang, Yeonghan;Kwon, Soonmu;Kim, BooSoon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.499-505
    • /
    • 2012
  • The purpose of this study was to find out the difference of radiation dose value through energy, exposure number, fluoroscopy time, the number of days of exposed scatter X-ray when TLD and OSLD is used in diagnostic radiology. The difference of value were measured by relative ratio and interval. Energy makes high relative ratio of TLD($1.81{\pm}0.41$) than OSLD($1.40{\pm}0.26$), exposure number makes high of OSLD($1.40{\pm}0.26$) than TLD($2.10{\pm}0.10$). There are no significant differences between relative ratio of TLD and OSLD in fluoroscopy time and the number of days of exposed scatter X-ray. But interval of relative ratio in the number of days of exposed scatter X-ray was narrowed in less 0.2. That means, the measurement of scatter X-ray could more confident in TLD and OSLD than the measurement of direct ray. In conclusion, we have to recognize the relative ratio of TLD and OSLD could be vary depending on exposed condition of radiation. And in some cases, double test of TLD and OSLD get more creditable results of dose value.

Self-reported Irritation Symptoms among Workers Exposed to Ultra-low Relative Humidity and Thionyl Chloride (극건조 환경에서 염화티오닐 동시 노출자의 자각증상 경험률)

  • Chae, Yoo Mi
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.6
    • /
    • pp.412-424
    • /
    • 2015
  • Objectives: An ultra dry air environment of nearly ${\leq}2%$ RH is often required in lithium battery factories. The objective of this study is to evaluate the subjective eye, pulmonary, nose, and skin symptoms of workers exposed to ultra-low relative humidity and thionyl chloride. Methods: We recruited 274 workers using a self-reported questionnaire in March 2014. Those who worked in ultra-low relative humidity and with thionyl chloride were identified and their prevalence of symptoms was compared with that of other workers. We excluded white collar workers, researchers and other workers who were exposed to various hazard factors, and finally included 164 workers. Results: There were significant differences in the rate of self-reported eye and skin symptoms between exposure group_1 and exposure group_2. Exposure group_2 experienced more frequent eye, and skin symptoms. Multinomial logistic regression analysis for experience of dry eye symptoms and skin symptoms in exposure group_2 showed that dry eye symptoms (odds ratio [OR], 6.33, 95% confidence interval [CI], 2.19-18.24, p<0.001), and itchiness (OR, 6.45, 95% CI, 1.94-21.43, p<0.01) were the significant variables. The complaints of workers experiencing ultra-low relative humidity and thionyl chloride were high compared with other workers. Conclusion: These findings suggest that exposure to ultra-low relative humidity and thionyl chloride may be associated with more frequent eye and skin symptoms than exposure to ultra-low relative humidity alone. The current precautions to protect workers from the adverse effects of ultra-low relative humidity and thionyl chloride appear to be insufficient, indicating that additional management plans to reduce symptoms should be considered.