• Title/Summary/Keyword: Relative Energy Value

Search Result 239, Processing Time 0.027 seconds

ADDITIVE NATURE OF DIGESTIBLE ENERGY AND RELATIVE ENERGY VALUES OF DIFFERENT ENERGY-YIELDING NUTRIENTS IN PRACTICAL TROUT DIETS

  • Kim, J.D.;Kaushik, S.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.3 no.3
    • /
    • pp.231-242
    • /
    • 1990
  • A study is reported which investigated the additive nature of digestible energy (DE) from dietary nutrients and to estimate the relative energy values of different energy-yielding nutrients in practical trout diets. A growth study was conducted over 12 weeks with 6 diets. Rainbow trout (Oncorhynchus mykiss) were fed diets once a day ad libitum. Digestible energy values determined and calculated had direct relationship indicating additive nature of such values for feed ingredients. Overall growth performance was best in a diet containing 33% digestible protein (DP) with a DP/DE ratio of 18.6. A reduction in digestible protein level with the same DP/DE rat io led to a significant decrease in growth and feed efficiency. The increase of 7% of lipid with concomitant decrease in protein resulted in the relative gain of 130% in growth and nutrient retention, suggesting that 1 g of lipid is equal to about 1.3 g of proteins in terms of net energetic value. Replacement of 10% of dietary lipid by carbohydrates led to a slight decrease in energy retention efficiency but to a great increase in lipid retention efficiency (130%) showing that dietary carbohydrates led to increased lipogenesis.

Energy Value of Carbohydrate and Lipids with Added Calcium for Growing Mice

  • Khalil, Dania A.;Owens, Fredric N.;Hanson, Christa F.
    • Preventive Nutrition and Food Science
    • /
    • v.5 no.2
    • /
    • pp.100-104
    • /
    • 2000
  • The caloric contribution of diets supplemented with sucrose, corn oil, or tallow with or without additional calcium was examined using female CD1 weanling mice. Mice were limit-fed a semi-purified diet alone or with added isocaloric amounts from sucrose, corn oil, or tallow for 28 days. In addition, diets with suppelmental fat contained either 0.60% or 1.5% calcium. Fecal fat and fecal soap excretions were greater (p<0.06) for mice fed tallow than for those fed corn oil. Mean metabolizable energy values for sucrose, tallow, and corn oil averaged 4.01, 7.96, and 8.94 kcal, respectively. Retention of digested energy from sucrose, tallow and corn oil averaged 13%, 10% and 21%, respectively. Hence, per gram of added nutrient, retained energy from tallow averaged 1.60 and that from corn oil averaged 4.11 times that of added sucrose. Retained energy from added corn oil was greater (p<0.01) than from added tallow. On a retained energy basis, the relative value for corn oil was greater and the relative value for tallow was less than the metabolizable energy ratio of fat to carbohydrate proposed by Atwater of 2.25.Added calcium depressed(p<0.01) digestibilities of both dry matter and energy with a greater(p<0.01) effect on tallow than on corn oil. These findings imply that the source of fat and calcium in the diet influence the avail-ability energy in diets and should be considered in feed formulations.

  • PDF

Energy demand analysis according to window size and performance for Korean multi-family buildings

  • Huh, Jung-Ho;Mun, Sun-Hye
    • Architectural research
    • /
    • v.15 no.4
    • /
    • pp.201-206
    • /
    • 2013
  • Special attention is required for the design of windows due to their high thermal vulnerability. This paper examines the problems that might arise in the application of the u-value, by reflecting the changes in the u-value of the window, depending on the window-to-wall ratio obtained in an energy demand analysis. Research indicates that the u-value of a window increases with an increase in the difference between the u-values of the frames and the glass. Relative to the changes in the u-value of the windows, the energy demand varied from 1.3% to 9.3%. Windows with a g-value of 0.3 or 0.5 displayed a higher energy demand than windows with a g-value of 0.7. Therefore, when the difference between the performance of the glass and the frame is significant, especially when the g-value is small, a modified heat transmission coefficient should be applied to the window size during the evaluation of the building energy demand.

Verification and Development of Lighting Design Data for Office in Korea (Focused on the Evaluation of Lighting Energy and Cooling Load) (사무소를 위한 조명설계 자료의 개발과 검증 (조명에너지와 냉방부하를 중심으로))

  • Kim, Eun-Hee;Suh, Seung-Jik
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1043-1048
    • /
    • 2006
  • This paper aimed to verify and develop lighting design data for offices in Korea. It focused on a Korean standard office value relative to lighting density and the evaluation of lighting energy and cooling load. When planning indoor lighting design, we generally utilize the lighting density value which is set $14W/m^2$ by the ASHRAE/IES standard office value. However, the value is not appropriate to apply in Korea where higher efficiency lamps are more popular than others. For calculation of a proper lighting density of Korea, we analysed distribution curves of luminous intensity(2-lamp fluorescent lighting fixture with Parabolic) and derived the new lighting density $12.64W/m^2$ as Korea standard office value. In the simulation using this value, it was shown that lighting energy and cooling load could be reduced.

  • PDF

Evaluation of Typical Solar Radiation Data by the TRY Methodology (TRY 방법론에 의한 표준일사량데이터 평가)

  • Yoo, Ho-Chun;Lee, Gwan-Ho;Kim, Kyoung-Ryul;Park, So-Hee
    • KIEAE Journal
    • /
    • v.7 no.6
    • /
    • pp.23-28
    • /
    • 2007
  • Limited fossil fuels and unstable energy supply are considered as one of the critical problems in architecture requiring large amounts of energy. In order to this challenge, environment-friendly architecture design is required. Clear data should be prepared to apply solar energy to architecture aggressively and properly. This study used FS statistical analysis data regarding average daily solar radiation of Seoul observed over 20 years to find out standard year and standard daily solar radiation. This study also aims to compare and evaluate an appropriate method of selecting a standard year which is too close to measurement value through comparison and analysis with daily solar radiation acquired by applying overseas researchers' suggesting weight factor. As a result, the data nearest to measurement value of daily solar radiation was UK CIBSE TRY(TYPE 2) displaying 0.100in t-statistic index. For UK CIBSE TRY(TYPE 2), weight factor was applied to three climatic elements except relative humidity. TYPE 1 and TYPE 3 recorded 0.343 and 0.367, respectively, showing higher record of t-statistic than TYPE 2. TYPE 1 was calculated through FS statistical value of single data about daily solar radiation with other climatic elements excluded. For TYPE 3, relative humidity was added to TYPE 2. In particular, since TYPE 2 was closer to the measurement value compared to the others, it is necessary to consider relationship with other climate elements if other climate elements are added.

Effect of Total Collimation Width on Relative Electron Density, Effective Atomic Number, and Stopping Power Ratio Acquired by Dual-Layer Dual-Energy Computed Tomography

  • Jung, Seongmoon;Kim, Bitbyeol;Yoon, Euntaek;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.165-171
    • /
    • 2021
  • Purpose: This study aimed to evaluate the effect of collimator width on effective atomic number (EAN), relative electron density (RED), and stopping power ratio (SPR) measured by dual-layer dual-energy computed tomography (DL-DECT). Methods: CIRS electron density calibration phantoms with two different arrangements of material plugs were scanned by DL-DECT with two different collimator widths. The first phantom included two dense bone plugs, while the second excluded dense bone plugs. The collimator widths selected were 64 mm×0.625 mm for wider collimators and 16 mm×0.625 mm for narrow collimators. The scanning parameters were 120 kVp, 0.33 second gantry rotation, 3 mm slice thickness, B reconstruction filter, and spectral level 4. An image analysis portal system provided by a computed tomography (CT) manufacturer was used to derive the EAN and RED of the phantoms from the combination of low energy and high energy CT images. The EAN and RED were compared between the images scanned using the two different collimation widths. Results: The CT images with the wider collimation width generated more severe artifacts, particularly with high-density material (i.e., dense bone). RED and EAN for tissues (excluding lung and bones) with the wider collimation width showed significant relative differences compared to the theoretical value (4.5% for RED and 20.6% for EAN), while those with the narrow collimation width were closer to the theoretical value of each material (2.2% for EAN and 2.3% for RED). Scanning with narrow collimation width increased the accuracy of SPR estimation even with high-density bone plugs in the phantom. Conclusions: The effect of CT collimation width on EAN, RED, and SPR measured by DL-DECT was evaluated. In order to improve the accuracy of the measured EAN, RED, and SPR by DL-DECT, CT scanning should be performed using narrow collimation widths.

Effects of lactic acid bacteria inoculation in pre-harvesting period on fermentation and feed quality properties of alfalfa silage

  • Ertekin, Ibrahim;Kizilsimsek, Mustafa
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.2
    • /
    • pp.245-253
    • /
    • 2020
  • Objective: To develop the fermentation quality and chemical composition of alfalfa (Medicago sativa Lam.) silage, plants were inoculated with different lactic acid bacteria (LAB) strains at field 24 hours before harvest. Methods: The treatment groups were as follow: silage without additive as a control and inoculated with each strains of Lactobacillus brevis (LS-55-2-2), Leuconostoc citerum (L. citerum; L-70-6-1), Lactobacillus bifermentans (L. bifermentans; LS-65-2-1), Lactobacillus plantarum (L. plantarum; LS-3-3) and L. plantarum (LS-72-2). All the silages were stored at 25℃. Parameters such as pH, microorganism and volatile fatty acid contents, crude protein, neutral detergent fiber, acid detergent fiber, net gas, metabolizable energy, organic matter digestibility, dry matter intake and relative feed value were measured to determine fermentation quality, chemical compositions and relative feed value of alfalfa silages. Results: Significant differences were found among the control and treated groups in terms of pH and microorganism contents at all opening times and crude protein, net gas, metabolizable energy and organic matter digestibility of final silage. The pH values ranged from 4.70 to 5.52 for all treatments and control silage had the highest value of overall treatments at T75d silages. Volatile fatty acid of silages was not influenced significantly by inoculations. However, lactic acid content of L. bifermentans (LS-65-2-1) was higher than the other treatments. The highest metabolizable energy and organic matter digestibility were recorded from L. citerum (L-70-6-1) inoculation. In addition, no significant differences were found among treatments in terms of neutral detergent fiber, acid detergent fiber, dry matter intake and relative feed value. Conclusion: Among the treated LAB isolates, L. bifermentans came into prominence especially in terms of organic acid composition and quality characters of silages.

Influence of slot width on the performance of multi-stage overtopping wave energy converters

  • Jungrungruengtaworn, Sirirat;Hyun, Beom-Soo
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.9 no.6
    • /
    • pp.668-676
    • /
    • 2017
  • A two-dimensional numerical investigation is performed to study the influence of slot width of multi-stage stationary floating overtopping wave energy devices on overtopping flow rate and performance. The hydraulic efficiency based on captured crest energy of different device layouts is compared with that of single-stage device to determine the effect of the geometrical design. The results show optimal trends giving a huge increase in overtopping energy. Plots of efficiency versus the relative slot width show that, for multi-stage devices, the greatest hydraulic efficiency is achieved at an intermediate value of the variable within the parametric range considered, relative slot width of 0.15 and 0.2 depending on design layouts. Moreover, an application of adaptive slot width of multi-stage device is investigated. The numerical results show that the overall hydraulic efficiency of non-adaptive and adaptive slot devices are approximately on par. The effect of adaptive slot width on performance can be negligible.

Relative ratio about dose value of thermoluminescence and optical stimulated luminescence dosimeter according to exposed condition in diagnostic radiation (진단방사선의 노출 조건에 따른 열형광선량계와 광자극형광 선량계의 선량값 상대비)

  • Kang, Yeonghan;Kwon, Soonmu;Kim, BooSoon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.499-505
    • /
    • 2012
  • The purpose of this study was to find out the difference of radiation dose value through energy, exposure number, fluoroscopy time, the number of days of exposed scatter X-ray when TLD and OSLD is used in diagnostic radiology. The difference of value were measured by relative ratio and interval. Energy makes high relative ratio of TLD($1.81{\pm}0.41$) than OSLD($1.40{\pm}0.26$), exposure number makes high of OSLD($1.40{\pm}0.26$) than TLD($2.10{\pm}0.10$). There are no significant differences between relative ratio of TLD and OSLD in fluoroscopy time and the number of days of exposed scatter X-ray. But interval of relative ratio in the number of days of exposed scatter X-ray was narrowed in less 0.2. That means, the measurement of scatter X-ray could more confident in TLD and OSLD than the measurement of direct ray. In conclusion, we have to recognize the relative ratio of TLD and OSLD could be vary depending on exposed condition of radiation. And in some cases, double test of TLD and OSLD get more creditable results of dose value.

An Experimental Study on Performance Characteristics of a Hydrogen Fuelled Spark Ignition Engine

  • Han, Sung Bin
    • Journal of Energy Engineering
    • /
    • v.23 no.1
    • /
    • pp.81-89
    • /
    • 2014
  • The purpose of this study is to obtain low-emission and high-efficiency in LPG engine with hydrogen enrichment. The objective of this paper is to clarify the effects of hydrogen enrichment in LPG fuelled engine on exhaust emission, thermal efficiency and performance. The compression ratio of 8 was selected to avoid abnormal combustion. To maintain equal heating value of fuel blend, the amount of LPG was decreased as hydrogen was gradually added. The relative air-fuel ratio was increased from 0.76 to 1.5, and the ignition timing was controlled to be at minimum spark advance for best torque (MBT).