• 제목/요약/키워드: Relative

검색결과 26,078건 처리시간 0.049초

높은 마디 고강도 철근의 이음성능 (Splice Length of High Relative Rib Area Reinforcing Bars)

  • 오하나;홍건호;송기모;최동욱
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.116-119
    • /
    • 2004
  • The use of higher strength materials frequently requires the change of design provisions. Following to the previous researches, high strength reinforcing bars have a weak point about the development and splice length. Based on the previous research about high relative rib area, bond strength between reinforcing bars and concrete can be improved by the control of rib height and spacing. But, the code provisions do not include these specific shape of reinforcing bars. So, the purpose of this paper is to determine the effect of relative rib area to the bond strength. This paper describes the experiment and analysis of 5 beam-spliced specimens containing D25 with relative rib areas ranging from 0.073 to 0.17. The test results are also analyzed to make a design formula about the calculation of splice length on the consideration of relative rib area.

  • PDF

A New Approach to Determine the Direction and Cause of Voltage Sag

  • Ahn, Seon-Ju;Won, Dong-Jun;Chung, Il-Yop;Moon, Seung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권3호
    • /
    • pp.300-307
    • /
    • 2008
  • Event source locating is very important to improving the power quality level. This paper presents a method to determine the relative location of the voltage sag source according to the cause. For this, the concept of the relative location of the source is defined first. Then, the main causes of voltage sag are classified and their characteristics are discussed. From these investigations, the rules to determine the relative location of event source are proposed for each type and the overall algorithm to identify the relative location and the kind of event source is presented. Finally, the proposed method is applied to the IEEE 13-bus test system and it is verified that the method can help to pinpoint the accurate location of the event source.

찰가자미(Microstomus achne) 초기생활기의 상대 성장 (Relative Growth of Microstomus achne (Pleuronectidae, PISCES) during Early Life Stage)

  • 변순규;강충배;한경호;김진구
    • 한국수산과학회지
    • /
    • 제46권6호
    • /
    • pp.970-972
    • /
    • 2013
  • We examined the relative growth of Microstomus achne during early life stages of laboratory-reared larvae and juveniles. Turning points in the relative growth of preanal length and upper jaw length against total length occurred during the settlement period (11.12-19.91 mm in total length). However, turning points in the relative growth of head length and eye diameter, as compared to total length, occurred during metamorphosis (17.57-22.47 mm in total length). Our results suggest that Microstomus achne concentrates its energy on the feeding apparatus (jaw) and digestive organs (intestine) rather than sensory or neural organs (eye, head) during early larval stage growth.

Relative Power Density Distribution Calculations of the Kori Unit 1 Pressurized Water Reactor with Full-Scope Explicit Modeling of Monte Carlo Simulation

  • Kim, Jong-Oh;Kim, Jong-Kyung
    • Nuclear Engineering and Technology
    • /
    • 제29권5호
    • /
    • pp.375-384
    • /
    • 1997
  • Relative power density distributions of the Kori Unit 1 pressurized water reactor are calculated by Monte Carlo modeling with the MCNP code. The Kori Unit 1 core is modeled on a three-dimensional representation of the one-eighth of the reactor in-vessel component with reflective boundaries at 0 and 45 degrees. The axial core model is based on half core symmetry and is divided into four axial segments. Fission reaction density in each rod is calculated by following 100 cycles with 5,000 test neutrons in each cycle after starling with a localized neutron source and ten noncontributing settle cycles. Relative assembly power distributions are calculated from fission reaction densities of rods in assembly. After 100 cycle calculations, the system converges to a k value of 1.00039 $\geq$ 0.00084. Relative assembly power distribution is nearly the same with that of the Kori Unit 1 FSAR. Applicability of the full-scope Monte Carlo simulation in the power distribution calculation is examined by the relative root moan square error of 2.159%.

  • PDF

초기재령 콘크리트의 수분확산과 자체건조에 관한 연구 (Moisture Diffusion and Self-desiccation of Concrete at Early Ages)

  • 김진근;이칠성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회 논문집(I)
    • /
    • pp.303-308
    • /
    • 1998
  • In the concrete structures exposed to environmental conditions at early ages, water movement occurs by moisture diffusion in the concrete, and self-desiccation of concrete is also occurred. Thus the internal relative humidity is changed from moisture diffusion and self-desiccation. Thus the internal relative humidity at each location in concrete includes the decrease by self-desiccation. Especially, for high-strength concrete the much unit cement content is used, so that the non-uniform relative humidity distribution is affected form self-desiccation at early ages. In this study, the internal relative humidity in concrete was measured at early ages, and the moisture diffusion component and self-desiccation component of total relative humidity were discussed.

  • PDF

상대운동이 있는 이차원 비정상 점성 유동 해석을 위한 비정렬 중첩격자기법 개발 (DEVELOPMENT OF AN UNSTRUCTURED OVERSET MESH METHOD FOR 2-D UNSTEADY VISCOUS FLOW SIMULATION WITH RELATIVE MOTION)

  • 정문승;권오준
    • 한국전산유체공학회지
    • /
    • 제11권2호
    • /
    • pp.1-7
    • /
    • 2006
  • An unstructured overset mesh method has been developed for the simulation of unsteady viscous flow fields around multiple bodies in relative motion. For this purpose, a robust and fast search technique is proposed for both triangle and high-aspect ratio quadrilateral cell elements. The interpolation boundary is defined for data communication between grid systems and an interpolation method is suggested for viscous and inviscid cell elements. This method has been applied to calculate the flow fields around 2-D airfoils involving relative motion. Validations were made by comparing the predicted results with those of experiments or other numerical results. It was demonstrated that the present method is efficient and robust for the prediction of unsteady time-accurate flow fields involving multiple bodies in relative motion.

Uncertainty Evaluation of a multi-axis Force/Moment Sensor

  • Kim, Gab-Soon
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제3권3호
    • /
    • pp.5-11
    • /
    • 2002
  • This paper describes the methods for calibration and evaluation of the relative expanded uncertainty of a multi-axis force/moment sensor. In order to use the sensor in the industry, it should be calibrated and its relative expanded uncertainty should be also evaluated. At present, the confidence of the sensor is shown with only interference error. However, it is not accurate, because the calibrated multi-axis force/moment sensor has an interference error as well as a reproducibility error of the sensor, etc. In this paper, the methods fur calibration and for evaluation of the relative expanded uncertainty of a multi-axis force/moment sensor are newly proposed. Also, a six-axis force/moment sensor is calibrated with the proposed calibration method and the relative expanded uncertainty is evaluated using the proposed uncertainty evaluation method and the calibration results. It is thought that the methods fur calibration and evaluation of the uncertainty can be usually used for calibration and evaluation of the uncertainty of the multi-axis force/moment sensor.

고속열차 동력차의 센터피봇 상대 회전각 계측에 관한 연구 (A Study on the Measurement of Relative Rotation of Center Pivot in Power Car of KTX)

  • 서승일;정우진
    • 한국철도학회논문집
    • /
    • 제9권3호
    • /
    • pp.277-281
    • /
    • 2006
  • The center pivot in the power car of KTX carries the traction force of the motor bogie to the carbody. The damage to the center pivot due to failure of swivel joint causes a serious hazard of the train. To prevent the hazard, information on the relative motion between bogie and carbody is necessary. In this paper, a method to measure the relative rotation of the center pivot is proposed and an actual test to verify the method and safety is conducted. The test results show that the rotation of the center pivot is within the allowable limit and the damage due to the relative motion doesn't take place.

초정밀 측정/가공 장비의 외부진동에 대한 상대변위의 추출과 진동성능 평가에 관한 연구 (A Study on the Vibrational Reduction Evaluation and the Relative Displacement in the External Vibration of Precision Measuring System)

  • 전종균;엄호성;김강부;원영재
    • 한국소음진동공학회논문집
    • /
    • 제12권1호
    • /
    • pp.65-72
    • /
    • 2002
  • Generally, there are laser operating equipments( aligner, stepper) and electronic microscope( SEM, TEM) as a high precision manufacturing and inspection equipment in semiconductor production companies, precision examination and measuring laboratories. Mostly, these equipments are characterized by projection and target part. The relative displacements between projection and target part are dominant roles in vibrational problem in these precision equipments. These relative displacements are determined by the position of incoming vibration and the difference of vibration response in projection and target part. In this study, the allowable vibrational limits are suggested and the vibrational reduction plans are proposed by measurement and analysis of vibration phenomenon in the Clean Room in PDP(plasma display panel) production building. The vibration performance is evaluated by comparison relative displacements between projection and target part before/after the vibration isolation plan.

중량함수율 및 상대함수율 비교에 따른 정량적인 함수율 산정에 대한 실험적 연구 (Experimental Research on the Comparison of Gravity Moisture Content and Relative Moisture Content in Calculating the Quantitative Percentage of Moisture Content)

  • 변용현;류동우
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.134-135
    • /
    • 2016
  • This study aims to compare relative moisture content and gravity moisture content in calculating the rational percentage of moisture content. High-strength concrete, which is made of blast-furnace slag and silica fume, was used as the compound for this study, and the specimens were made into a saturated condition through the vacuum suction. According to the results of this study, all specimens were completely dried when they were under the temperature of 105℃ for more than 31 days. They were fully saturated after 72 hours through vacuum suction. In addition, relative moisture content responded more sensitively to moisture content than gravity moisture content did, so it can be concluded that relative moisture content is better in calculating the rational percentage of moisture content.

  • PDF