• Title/Summary/Keyword: Reinforcing Rib

Search Result 49, Processing Time 0.033 seconds

Bond Analysis of Ribbed Reinforcing Bars

  • Park, Oan-Chul
    • KCI Concrete Journal
    • /
    • v.13 no.2
    • /
    • pp.19-25
    • /
    • 2001
  • A simple expression to predict bond strength of reinforcing bars with rib deformation to the surrounding is derived for the case of splitting bond failure. Finite element analysis is used to model the confining behavior of concrete cover. The roles of the interfacial properties, specifically, the friction coefficient, cohesion, the relative rib area and the rib face angle are examined. Values of bond strength obtained using the analytical model are in good agreement with the bond test results from the previous studies. The analytical model provides insight into interfacial bond mechanisms and the effects of the key variables on the bond strength of deformed bars to concrete. Based on the comparison between the analytical results and the test results, the values of cohesion, coefficient of friction, and the effective rib face angle are proposed.

  • PDF

Evaluate Anchorage Strength of High Relative Rib Area Bars Using Hook Test Specimens (갈고리 시험체를 이용한 높은마디면적 철근의 정착성능)

  • Seo Dong Min;Hong Gi Suop;Choi Dong Uk;Choi Oan Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.327-330
    • /
    • 2005
  • Bond failure of reinforcing bar generally take place by splitting of the concrete cover as bond force between concrete and reinforcing bars exceeds the confinement of the concrete cover and reinforcement. However, the confinement force in practice has a limitation. Thus, the only variable is the bearing area corresponding to the change of bond force. In this study, to the evaluate anchorage strength of high relative rib area bars, hook bond test specimens are tested and the results are discussed. Higher rib height bars when bars are confined showed higher anchorage strength than lower rib higher bars.

  • PDF

An Experimental Study on Bond Strength of High-Strength Reinforcing Bars with High Relative Rib Area (높은 마디면적 고강도 철근의 부착강도에 관한 실험적 연구)

  • Hong Geon-Ho;Choi Dong-Uk;Choi Oan-Chul;Hong Gi-Suop
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.3 s.87
    • /
    • pp.375-384
    • /
    • 2005
  • The effects of bar deformation properties on bond of steel reinforcing bars to concrete are experimentally studied to predict the bond strength. Based on the previous research about high relative rib area, bond strength between reinforcing bars and concrete can be improved by the control of rib height and spacing. But, the equations in Korean code provisions to estimate development and splice length do not include these specifications of reinforcing bars. So the purpose of this paper is to determine the effect of relative rib area to the bond strength. This paper describes 2 kinds of experimental researches. Thirty beam-end specimens were tested to investigate the effects of bar size and relative rib areas ranging from 0.112 to 0.162. And, twelve lap-splice beam specimens were tested to the same variables. Each test results are normalized and compared with the proposed equations of ACI 408 committee. The results show that bond strength is increased as bar size and the relative rib area(Rr) increase. The distribution of flexural cracks and failure aspect do not appear to be affected by $R_r$.

A FEA Study on the Bond Property according to the Rib-Shape of Reinforcement (철근 마디형상에 따른 부착특성에 관한 해석적 연구)

  • Mihn, Joon-Soo;Hong, Geon-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.2
    • /
    • pp.38-46
    • /
    • 2014
  • Effects of various parameters on bond property between reinforcing bar and concrete are investigated in many researchers, and various study is on going to improve the bond strength. Properties of interface between reinforcement and concrete is important role in bond property. This study analyzed the interfacial bond mechanism between deformed bar and concrete by finite element analysis (FEA) to evaluate the effect of rib shape. The FEA model in this study is simplified 2D plane stress model. The variables of analysis are selected by rib angle, rib height, rib spacing and relative rib area. From the results of analysis, reinforcing bars with rib angle $30{\sim}60^{\circ}$ showed better bond strength than the others. Bond strength ratio following to the rib height is proportionally increased up to the $0.12d_b$, but rib spacing has little effect on bond strength. The results also indicated that relative rib area can be efficiently represented the properties of deformed shape in reinforcing bars, and zigzagged rib height shape showed excellent bond strength increase.

Effects of Bar Deformation on Bond between Reinforcing Steel and Concrete Subjected In Cyclic Loading (반복하중시 철근의 마디형태에 따른 부착특성)

  • 최완철;이재열;이웅세
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.3
    • /
    • pp.244-250
    • /
    • 2001
  • One of the reasons for brittle failure in reinforced concrete structures subjected to severe earthquake is due to large slip between reinforcing steel and concrete. This study aims to evaluate effects of deformation patterns of ribbed reinforcing bars on bond under cyclic loading. Bond test specimens were constructed with machined bars to test the newly developed reinforcing bars with high relative rib areas. The degree of confinement is also another key parameter in this bond test. From the test results under monotonic and cyclic loading, bond strength and stiffness were evaluated. Bond strength and bond stiffness increase as relative rib areas under cyclic loading for specimens highly confined by transverse reinforcement. The increase rates of the bond performance under cyclic loading are larger than those of specimens under monotonic loading. The developed bars with high relative rib areas will contribute for better bond performance for reinforced concrete structures subjected to severe seismic loadings.

Self-Diagnosis for Fracture Prediction of Concrete Reinforced by New Type Rib CFGFRP Rod and CF Sheet (신형 리브재 CFGFRP 보강근 및 CF 보강시트로 보강된 콘크리트의 파괴예측 자가진단)

  • Park, Seok-Kyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.2
    • /
    • pp.115-123
    • /
    • 2007
  • For investigating self-diagnosis applicability, a method based on monitoring the changes in the electrical resistance of carbon fiber reinforced concrete has been tested. Then after examining change in the value of electrical resistance at each flexural weight-stage of carbon fiber in CFGFRP (carbon fiber and glass fiber reinforcing plastic) with new type rib and carbon sheet for concrete reinforcing, the correlations of electrical resistance and load as a function of strain, deflection were analyzed. As the results, it is clarified that when carbon fiber rod, rib and sheet fracture, the electrical resistance of it increase largely, and specially in case of CFGFRP, afterwards glass fiber tows can be resist the load due to the presence of the hybrid (carbon and glass) reinforced fiber. Therefore, it can be recognized that reinforcing bar and new type rib of CFGFRP and sheet of CF could be applied for self-diagnosis of fracture in reinforced FRP concrete.

Roles of Bearing Angle in Bond Action of Reinforcing Bars to Concrete

  • Choi OanChul
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.5 s.83
    • /
    • pp.719-724
    • /
    • 2004
  • The ribs of deformed bars can split the cover concrete by wedging action or shear off the concrete in front of the ribs. As slip of deformed bars increases, the rib face angle is flattened by the crushed concrete wedge, which reduces the rib face angle to a smaller bearing angle. The roles of bearing angle are explored to simulate this observation. Analytical expressions to determine bond strength for splitting and pullout failure are derived, where the bearing angle is a key variable. As the bearing angle is reduced, splitting strength decreases and shearing strength increases. When splitting strength becomes larger than shearing strength, the concrete key is supposed to be sheared off and the bearing angle is reduced with decreasing the splitting strength. As bars slip, bearing angle decreases continually so that splitting bond strength is maintained to be less than shearing bond strength. The bearing angle is found to play a key role in controlling the bond failure and determination of bond strength of ribbed reinforcing steel in concrete structures.

Static Tests of ㄱ Type Perfobond Rib Shear Connectors when using Steel Tube (원형강관에 부착된 ㄱ형 perfobond 리브 전단연결재의 정적실험)

  • Lee Heung-Su;Chung Chul-Hun;Choi Wae-Ho;Kim Seok-Ki;You Sung-Kun;Kim Young-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.778-781
    • /
    • 2004
  • This paper summarizes the results of push-out test specimens with a new type of shear connector called ㄱ type perfobond rib. This connector is a flat steel plate with a number of holes punched through and strengthen rib's head part. According to experiment result, ㄱ type perfobond rib shear connector appeared that resistance force is increased than stud shear connector by $108\%$ and perfobond rib shear connector by $26\%$. The results obtained indicate that the perfobond rib connector is a viable alternative to the headed studs. An appreciable improvement in the shear capacity of the connection was observed when additional reinforcing bars were passed through the perfobond rib holes. For composite beams with concrete filled steel tubes, ㄱ type perfobond shear connectors exhibit adequate ductility and substantially higher capacities.

  • PDF

Bond Performance of Steel to Concrete subjected to Cyclic Loading (반복하중시 철근의 마디형태에 따른 부착특성)

  • 이재열;이웅세;최완철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.545-550
    • /
    • 2000
  • Bond between reinforcing bars and the surrounding concrete is supposed to safely transfer load in the design process of reinforced concrete structures. Bar with high relative rib area will be studied further not only static load but also dynamic loading conditions to sustain better performance of bond for reinforced concrete structures under earthquake. To determine the bond behavior of high ribbed bars in beam and column joints under repeated loads, 31 pullout specimens were tested. Bond strength increases as relative rib area increases. Also the effect of relative rib area on bond is larger in cyclic loading than in monotonic loading.

  • PDF

Bond Performance of FRP Reinforcing Bar for Concrete Structures after Chemical Environmental Exposure (화학적 환경에 노출된 콘크리트 보강용 FRP 보강근의 부착 성능)

  • Park, Chan-Gi;Won, Jong-Pil
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.3
    • /
    • pp.73-81
    • /
    • 2004
  • FRP reinforcing bars(rebars) are produced through a variety of manufacturing process includes pultrusion, and filament winding and braiding etc. Each manufacturing method produces a different surface condition of FRP rebar. The surface properties of FRP rebar is an important property for mechanical bond with concrete. Current methods of providing surface deformation to FRP rebars include helical wrapping, surfaces and coating and rib molding. The problem with the helical wrapping method is that it can not provide enough surface deformation for good bond and it can be easily sheard off from the FRP rebars. Sand coating and rib molding provide surface deformation only to the outer FRP skins. Therefore, FRP rebar has about 60% of bond strength of steel rebar. The main objective was to evaluate the bond properties of FRP rebar after environmental exposure. Five types of FRP rebar includes CFRP ISO, GFRP Aslan, AFRP Technora CFRP(Korea), and GFRP(Korea) rebars performed direct bond tests. Also, FRP rebar bond specimens were subjected to exposure conditions including alkaline solution, acid solution, salt solution and deionized water etc. According to bond test results, CFRP(Korea) and CFRP(Korea) rebars were found to have better bond strength with concrete than previous FRP rebars. Also, FRP(Korea) rebar had more than about 70% in bond strength of steel rebar.