• Title/Summary/Keyword: Reinforced earth retaining wall

Search Result 127, Processing Time 0.045 seconds

Reinforced Effect of Earth Body Reinforced by Attachment-type Geogrid (부착형 지오그리드 보강토체의 보강효과)

  • 고태훈;이성혁;황선근;이진욱
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.277-282
    • /
    • 2002
  • The objective of this study is to suggest the optimal method for reinforced earth retaining wall through the appropriate selection of reinforcing materials, development of design criteria. Thus, the efficient land utilization and securing safety in the train operation in service lines could be achieved. For this goal, a large scale shear laboratory test was carried out to evaluate the reinforced effect of earth body reinforced by attachment-type geogrid.

  • PDF

Performance of retaining walls with and without sound wall under seismic loads

  • Mock, Erin;Cheng, Lijuan
    • Earthquakes and Structures
    • /
    • v.7 no.6
    • /
    • pp.909-935
    • /
    • 2014
  • The seismic characteristics of two semi-gravity reinforced concrete cantilever retaining walls are examined via an experimental program using an outdoor shake table (one with and the other without concrete masonry sound wall on top). Both walls are backfilled with compacted soil and supported on flexible foundation in a steel soil container. The primary damages during both tests are associated with significant lateral displacements of the wall caused by lateral earth pressure; however, no collapse occurs during the tests. The pressure distribution behind the walls has a nonlinear trend and conventional methods such as Mononobe-Okabe are insufficient for accurate pressure estimation.

Experimental Study on a Gabion Wall Reinforced by a Relatively Short Reinforcement (짧은 보강재가 부착된 가비온 옹벽의 모형실험)

  • Kim, Joon-Seok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.7 no.1
    • /
    • pp.7-11
    • /
    • 2008
  • The Gabion wall have been developed on the basis of experimental works and the method is actively used in the actual site. In this study, a relatively small-scale experiment was carried out to figure out the failure behavior of a Gabion wall reinforced by a relatively short wire net to enlarge the axial tensile resistance which is important factor in the stability. The horizontal and vertical displacement of Gabion wall have been acquired and analyzed. Furthermore the results are compared with the test results for a non-reinforced Gabion wall that is performed at the same condition.

  • PDF

Site Monitoring of the Retaining Wall Reinforced by Geogrids with Block Type Facings (지오그리드 보강토 옹벽의 계측평가)

  • Kim, Jin-Man;Lee, Dae-Young;Ma, Sang-Joon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.1
    • /
    • pp.106-114
    • /
    • 2006
  • Uses of geosynthetics as a reinforcing material for earth structures have ever increased due to their excellent economy. fine external appearance. and easy construction. In the current practice of geosynthetics. however, the lacks of the standardized method of evaluating the soil/geosynthetics friction properties and the inconsistency of conventional design methods develop confusion to the civil engineers. The purpose of site monitoring of the retaining wall reinforced by geogrids was to evaluate the applicability of existing design methods to, and performance of. CHAMSTONE wall system. Full scale field performance during and after construction was monitored by incorporating instrumentation including strain gauges on the geogrid and soil pressure cells. The difference of the reinforcing effects of geosynthetics embedded in the soil will be also investigated by comparing of the line and curve types of retaining wall reinforced by geogrids with block type facings.

Design of the Green Wall System considering Distribution Effect of Earth Pressure by Soil Nail (네일의 토압분담 효과를 고려한 Green Wall 시스템의 설계)

  • Park, Si-Sam;Cho, Sung-Han;Yoo, Chan-Ho;Kim, Hong-Taek;Kim, Yong-Yeon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1038-1045
    • /
    • 2006
  • The Green Wall is highest eco-system among a segmental retaining wall systems. Recently, the demand of high segmental retaining wall (SRW) is increased in domestic. The soil nailing system is applied in order to maintain the high SRW stability for steeper slope. However, the proper design approach that can consider the earth pressure reduction effects in soil nailing system has not been proposed. This study was performed to introduce the design case by 'Two-Body Translation mechanism' to be able to consider distribution of earth pressure in the soil nailing when designing the green wall using soil nailing system. Also, this study attempts to evaluate the earth pressure change when advanced soil nailing system is constructed using $FLAC^{2D}$ ver. 3.30 program and 'Two-Body Translation mechanism'. Also in this study, various parametric studies using numerical methods as shear strength reduction (SSR) technique and limit equilibrium technique were carried out. In the parametric study, the length ratio and the bond ratio of the soil nailing were changed to identify the earth pressure reduction effect of the retaining wall reinforced by soil nailing.

  • PDF

A case Study on Collapse Causes and Restoration of Retaining Wall with Vegetated Concrete Block (식생블록 옹벽의 붕괴원인 및 복구방안에 관한 사례 연구)

  • Hong, Gigwon;You, Seung-Kyong;Yun, Jung-Mann;Park, Jong-Beom;Lee, Kwang-Wu
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.4
    • /
    • pp.105-115
    • /
    • 2016
  • This paper describes a restoration of retaining wall, which was collapsed by rainfall. The failure causes was analyzed by field case, and then the countermeasure was suggested. The failure causes confirmed that observance of design and construction criteria was insufficient. It also was the climate condition like a rainfall and inappropriate construction management. The stability analysis for retaining wall, soil improvement and reinforced earth wall was conducted to confirm validity of the countermeasure. The analysis results showed that the suggested construction method satisfied in required safety factors. Therefore, it should be secured the stability of the structure based on the application of appropriate design method and construction management, when structure was constructed.

Case Study on the Design of Earth Retaining and Retention Wall Using Pre-casted Concreted Pile(PHC) (기성콘크리트말뚝(PHC)을 이용한 옹벽겸용 흙막이설계사례)

  • Han, Jung-Geun;Cho, Young-Ryang;Kim, Sang-Kwi;Park, Sang-Cheol;Eo, Yun-Won
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.8 no.3
    • /
    • pp.33-42
    • /
    • 2005
  • The bearing methods using pile of steel itself or reinforced concrete has been applying which in excavated depth was not deep. Also, the retaining wall as resisting structure to lateral force has taken weakness that the cure periods of concreted is long. Recently, with the material cost of steel, the application of cement is more increasing trend. In this study, the design methods of earth retaining and retention wall within the pre-casted concrete pile, PHC(Pretentioned spun High strength Concrete piles), was proposed which in the ground condition of excavated depth was not deep. The typical ground conditions, cohesive and non-cohesive soil, was considered as follows; soil strength as internal friction angle and UU(Undrained Unconsolidation triaxial test) strength, soil reaction and stabilization of structures. The application of design methods could be confirmed through the comparing and analyzing between measured data and utility software for the design.

Experimental Study on the application of reinforced retaining walls to the railroad (보강토 옹벽의 철도 구조물 적용에 관한 실험적 연구)

  • Kim Yong-Jun;Kim Jun-Young;Kim Kyung-Taek;Yeom Hyeong-Jin
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1020-1025
    • /
    • 2004
  • This research reviews the characteristics of earth pressure incurred by GRS-RW mainly used in the railroad design in order to resist large lateral load caused by train and additional load induced by facilities such as noise barrier fences, electric poles, etc. The results of test shows the existence of arching effect that horizontal earth pressure increases in the backfill while earth pressure applying to the wall reduced under GRS-RW system. In both cases, unreinforced wall and GRS-RW system, the coefficient of earth pressure (K) is about 0.4 at the rest. However, after lateral displacement occurs, the earth pressure nearly reduce down to zero under GRS-RW system while the earth pressure decreases up to 0.12 in case of unreinforced retaining wall.

  • PDF

A Study on the Application of Soil-Reinforced Retaining Wall for Excavation Slope (절토사면에서 보강토 옹벽의 적용성 연구)

  • Byun, Yoseph;Wrryu, Woongryeal;Lee, Dongho;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.2
    • /
    • pp.53-60
    • /
    • 2010
  • Considering environmental issues and lack of space, it is a necessity to minimize the amount of excavation. Various types of excavation methods are being used in practice. This study proposes a reasonable method for estimating the earth pressure acting on a reinforced wall in front of a excavated slope. The measured data in the field and numerical analyses were used. Results of the study shows that the earth pressure acting on the excavated wall is less than that estimated by Rankine's equations. It was shown that when the excavated slope is used with the reinforced wall, the pressures acting on the reinforced wall can be greatly reduced.

Case Study on Global Slope Failure Case of Segmental Retaining Wall (블록식보강토옹벽의 전면 사면붕괴 사례연구)

  • Han, Jung-Geun;Cho, Sam-Deok;Jeong, Sang-Seom;Lee, Kwang-Wo;Hong, Ki-Kwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.4 no.2
    • /
    • pp.47-56
    • /
    • 2005
  • Recently, geosynthetic reinforced earth walls are gradually replacing conventional concrete retaining walls for reasons of economy, expediency of construction, and aesthetics. A number of reinforced soil walls having more than 10m heights have been constructed to make more effective development in the country. However, mistakes in design and construction of reinforced earth walls have resulted in many troubles such as failure of reinforced earth walls, horizontal deformationor breakdown of facings, and so forth during or after construction. In this paper, a case study on global sliding failure of a geogrid-reinforced tiered wall is carried out to investigate the causes of the failure and suggest the proper countermeasures. From the subsurface investigation and field instrumentation, It is found that the cause of the global sliding failure was occurred by decreasing of bearing capacity of foundation ground induced by infiltration of rainwater.

  • PDF