• Title/Summary/Keyword: Reinforced earth method

Search Result 129, Processing Time 0.031 seconds

Resistivity Survey on Stylobate of Five-story Stone Pagoda in Tamni-ri, Uiseong (의성 탑리리 오층석탑 기단부 전기비저항 탐사)

  • Oh, Hyundok;Kwon, Moonhee
    • Geophysics and Geophysical Exploration
    • /
    • v.23 no.4
    • /
    • pp.253-260
    • /
    • 2020
  • The five-story stone pagoda in Tamni-ri located in Uiseong County in Gyeongsangbuk-do had an unstable upper structure, and the structural deformation of the foundation stone and the stylobate was severe. In order to repair the base of the pagoda, it must be confirmed if there are support stones inside the base. Resistivity survey was performed to study the inner base stone structure during the repair work. The stylobate was exposed soil and broken stones after removing the walls and the cover of the stylobate. Modified pole-dipole array II was used for the resistivity survey, and compared with the typical pole-dipole array method. And in this study, a physical scale-down model experiment was performed to compare and analyze distortions caused by severe topographical undulations such as right-angled lines. The results show that the stylobate of Five-story Stone Pagoda in Tamni-ri Uiseong has base stones inside the reinforced filling soil and are located beneath the pillar of the body and supporting the pagoda.

An Experimental Study on Local Stability of Eco-block (생태축조블록의 국부적 안정성에 관한 실험적 연구)

  • Lee, Seung-Hyun;Lee, Su-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2866-2871
    • /
    • 2011
  • In this study, computation method of tensile load which develops in tie-bar of reinforced earth, connection strength between tie-bar and eco-block and shear strength of the interface between two eco-blocks were verified by experiments. According to the test results of connection strength test, peak tensile load of D13 deformed bar were close to allowable tensile load of it for situation of infill with soil. Connection strengths of D10 and D13 deformed bars were greater than the allowable tensile load of those respectively for situation of infill with concrete. According to the test results of shear strength of the interface between two eco-blocks, shear resistance parameters, ${\alpha}_u$ and ��${\lambda}_u$ were evaluated as 1.7kN/m and 2$27.6^{\circ}$ respectively.

Geophysical Explorations for Safety Analysis of Bangeosan-Maaebul(Stone Relief Bhaisajyaguru triad at Mt. Bangeosan) (방어산 마애여래입상의 안전진단을 위한 지구물리탐사)

  • O, Seon-Hwan;Seo, Man-Cheol
    • Journal of the Korean Geophysical Society
    • /
    • v.4 no.1
    • /
    • pp.11-20
    • /
    • 2001
  • Seismic refraction and electrical resistivity surveys were conducted in Bangeosan Maaebul site located in Haman, Kyungnam, in order to present geophysical safety analysis method for masonry cultural properties. Seismic refraction exploration revealed that the ground was composed of three layers in term of seismic wave velocity; the upper, medium, and lower layers. The low velocity ranging from 308 to 366 m/sec in upper layer suggests weathered soil, the intermediate velocity from 1906 to 2090 m/sec in the medium layer indicates weathered rocks, and the high velocity from 5061 to 5650 m/sec in the lower layer implies extremely hard rocks. Our seismic result suggests that the upper and medium layer around the Maaebul should be reinforced to support the construct. The result of electric resistivity survey shows that there exists a low resistivity zone, ranging from 131 to 226 Ohm-m, at the right side of the Maaebul with the direction of NE-NNE. This area is the weakness zone as it plays role of the underground water passage in rainy season.

  • PDF

Geotechnical Engineering Progress with the Incheon Bridge Project

  • Cho, Sung-Min
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.133-144
    • /
    • 2009
  • Incheon Bridge, 18.4 km long sea-crossing bridge, will be opened to the traffic in October 2009 and this will be the new landmark of the gearing up north-east Asia as well as the largest & longest bridge of Korea. Incheon Bridge is the integrated set of several special featured bridges including a magnificent cable-stayed girder bridge which has a main span of 800 m width to cross the navigation channel in and out of the Port of Incheon. Incheon Bridge is making an epoch of long-span bridge designs thanks to the fully application of the AASHTO LRFD (load & resistance factor design) to both the superstructures and the substructures. A state-of-the-art of the geotechnologies which were applied to the Incheon Bridge construction project is introduced. The most Large-diameter drilled shafts were penetrated into the bedrock to support the colossal superstructures. The bearing capacity and deformational characteristics of the foundations were verified through the world's largest static pile load test. 8 full-scale pilot piles were tested in both offshore site and onshore area prior to the commencement of constructions. Compressible load beyond 30,000 tonf pressed a single 3 m diameter foundation pile by means of bi-directional loading method including the Osterberg cell techniques. Detailed site investigation to characterize the subsurface properties had been carried out. Geotextile tubes, tied sheet pile walls, and trestles were utilized to overcome the very large tidal difference between ebb and flow at the foreshore site. 44 circular-cell type dolphins surround the piers near the navigation channel to protect the bridge against the collision with aberrant vessels. Each dolphin structure consists of the flat sheet piled wall and infilled aggregates to absorb the collision impact. Geo-centrifugal tests were performed to evaluate the behavior of the dolphin in the seabed and to verify the numerical model for the design. Rip-rap embankments on the seabed are expected to prevent the scouring of the foundation. Prefabricated vertical drains, sand compaction piles, deep cement mixings, horizontal natural-fiber drains, and other subsidiary methods were used to improve the soft ground for the site of abutments, toll plazas, and access roads. Light-weight backfill using EPS blocks helps to reduce the earth pressure behind the abutment on the soft ground. Some kinds of reinforced earth like as MSE using geosynthetics were utilized for the ring wall of the abutment. Soil steel bridges made of corrugated steel plates and engineered backfills were constructed for the open-cut tunnel and the culvert. Diverse experiences of advanced designs and constructions from the Incheon Bridge project have been propagated by relevant engineers and it is strongly expected that significant achievements in geotechnical engineering through this project will contribute to the national development of the longspan bridge technologies remarkably.

  • PDF

Analysis on the characteristics of the earth pressure distribution induced by the integrated steel pipe-roof construction (일체형 강관 파이프루프 시공에 따른 주변 지반의 토압 분포 특성 분석)

  • Sim, Youngjong;Jin, Kyu-Nam;Song, Ki-Il
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.5
    • /
    • pp.455-468
    • /
    • 2013
  • In recent, various types of steel pipe-roof methods, which is reinforced by mortar after propulsion of steel pipe into the ground, have been used for the construction of trenchless underpass. Integrated steel pipe-roof has flexural stiffness and can resist against overburden load and reduce the stress acting on the concrete underpass structures. Due to arching effect, vertical and horizontal stress distribution around the steel pipe-roof is changing. In this study, therefore, the characteristic of stress distribution around the underpass induced by the construction of integrated steel pipe-roof is investigated by using numerical method. To examine the soil-structure interaction, interface element is introduced. Results show that vertical stress acting on the concrete structure placing inside the steel pipe-roof is significantly reduced due to arching effect and flexural stiffness of integrated steel pipe-roof. Design load can be reduced and effective design of underpass will be available if the earth pressure reduction due to arching effect is considered in the design stage.

Inspecting Stablity of DSM method with Grouting on Tunnel Face using Chamber Test and Numericlal Analysis (토조실험과 수치해석을 이용한 막장면 그라우팅 DSM공법의 안정성 검토)

  • Kim, Young-Uk;Park, Young-Bok;Kim, Li-Sak;Kim, Nak-Kyeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.677-683
    • /
    • 2016
  • In urban areas, underground tunnel construction sites have spread widely to accommodate rapidly increasing traffic volume along with a high-degree economic growth. Earth tunneling might be adapted frequently for the underground space securing, and various tunneling methods have been developed to stabilize the tunnel face and crown. Among them, the DSM (divided shield method) is gaining popularity for its enhanced stability and construction efficiency. This method has its foundation from the Messer Shield method, which is one of the trenchless special tunneling methods. This study examined the effects of face reinforcement on construction the sequence through a large scale soil chamber test and numerical analyses. The chamber has a size of a 1/2 scale of the real tunnel. Surface settlements were measured according the tunneling process. Commercially available software, MIDAS GTS, was used for numerical analysis and its result was compared with the values obtained from the chamber test. The results of the study show that both settlements of the embanked soils and the stress of the tunnel girder are located within the safe criteria. Overall, this study provides basic data and the potential of using a reinforced tunnel face to enhance DSM applications.

Study on the Conservation of Scale Armor Using Duplication Technique - Focused on the Case of the Conservation Treatment of the Excavated Artifact from Jinyoung 2-Area, Gimhae - (복제 기법을 이용한 찰갑의 보존처리 - 김해 진영 2지구 출토품의 보존처리 사례를 중심으로 -)

  • Kim, Dong Min;Park, Jung Hyeok;Cho, Hyun Kyung;Cho, Nam Chul
    • Journal of Conservation Science
    • /
    • v.31 no.1
    • /
    • pp.75-86
    • /
    • 2015
  • A scale Armor is usually excavated in a scattered form weakened by corrosion after its burial. Therefore, they should be brought into the indoor in a safe environment for the on-site conservation treatment as it was excavated. They should be placed on a stable support with a reinforced base in the indoor treatment. In this process, the bottom surface which can not be observed after the conservation treatment is placed for a record by actual survey and photography. But this method had a limit on figuring out the whole aspects of the artifact. For compensating the defect, duplication of the artifact was considered as an alternative method for the previous two methods in the case of conservation of the scale Armor from Jinyoung 2-Area, Gimhae. Neck guard was excavated in a distorted form by the earth pressure, and was hard to recognize the original shape. However, whole real material of its original form was secured through the combination of each duplicated lamellae. Throughout the application of the duplication technique in the process of conservation of scale Armor and neck guard, it could secure the real material of the bottom surface and elevate the understanding of the artifact. Moreover, a constitution of the armor could be identified more effectively.

Target Reliability Index of Single Gravel Compaction Piles for Limit State Design (한계상태설계를 위한 단일 쇄석다짐말뚝의 목표신뢰도지수)

  • You, Youngkwon;Lim, Heuidae;Park, Joonmo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.2
    • /
    • pp.5-15
    • /
    • 2014
  • Target reliability index in the limit state design indicated the safety margin and it is important to determine the partial factor. To determine the target reliability index which is needed in the limit state design, the six design and construction case histories of gravel compaction piles (GCP) were investigated. The limit state functions were defined by bulging failure for the major failure mode of GCP. The reliability analysis were performed using the first order reliability method (FORM) and the reliability index was calculated for each ultimate bearing capacity formulation. The reliability index of GCP tended to be penportional to the safety factor of allowable stress design and average value was ${\beta}$=2.30. Reliability level that was assessed by reliability analysis and target reliability index for existing structure foundations were compared and analyzed. As a result, The GCP was required a relatively low level of safety compared with deep and shallow foundations and the currd t reliability level were similar to the target reliability in the reinforced earth retaining-wall and soil-nailing. Therefore the target reliability index of GCP suggested as ${\beta}_T$=2.33 by various literatures together with the computed reliability level in this study.

Reliability Based Stability Analysis and Design Criteria for Reinforced Concrete Retaining Wall (신뢰성(信賴性) 이론(理論)에 의한 R.C.옹벽(擁壁)의 안정해석(安定解析) 및 설계규준(設計規準))

  • Cho, Tae Song;Cho, Hyo Nam;Chun, Chai Myung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.3
    • /
    • pp.71-86
    • /
    • 1983
  • Current R.C. retaining wall design is bared on WSD, but the reliability based design method is more rational than the WSD. For this reason, this study proposes a reliability based design criteria for the cantilever retaining wall, which is most common type of retaining wall, and also proposes the theoretical bases of nominal safety factors of stability analysis by introducing the reliability theory. The limit state equations of stability analysis and design of each part of cantilever retaining wall are derived and the uncertainty measuring algorithms of each equation are also derived by MFOSM using Coulomb's coefficient of the active earth pressure and Hansen's bearing capacity formula. The levels of uncertainties corresponding to these algorithms are proposed appropriate values considering our actuality. The target reliability indices (overturning: ${\beta}_0$=4.0, sliding: ${\beta}_0$=3.5, bearing capacity: [${\beta}_0$=3.0, design for flexure: [${\beta}_0$=3.0, design for shear: ${\beta}_0$=3.2) are selected as optimal values considering our practice based on the calibration with the current R.C. retaining wall design safety provisions. Load and resistance factors are measured by using the proposed uncertainties and the selected target reliability indices. Furthermore, a set of nominal safety factors, allowable stresses, and allowable shear stresses are proposed for the current WSD design provisions. It may be asserted that the proposed LRFD reliability based design criteria for the R.C. retaining wall may have to be incorporated into the current R.C. design codes as a design provision corresponding to the USD provisions of the current R.C. design code.

  • PDF