• Title/Summary/Keyword: Reimplantation

Search Result 68, Processing Time 0.022 seconds

Evaluation of failed implants and reimplantation at sites of previous dental implant failure: survival rates and risk factors

  • Park, Yu-Seon;Lee, Bo-Ah;Choi, Seong-Ho;Kim, Young-Taek
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.3
    • /
    • pp.230-241
    • /
    • 2022
  • Purpose: The purpose of this study was to evaluate failed implants and reimplantation survival and to identify the relative risk factors for implant re-failure. Methods: Ninety-one dental implants were extracted between 2006 and 2020 at the National Health Insurance Service Ilsan Hospital, including 56 implants in the maxilla and 35 implants in the mandible that were removed from 77 patients. Patient information (e.g., age, sex, and systemic diseases) and surgical information (e.g., the date of surgery and location of the implants and bone grafts) were recorded. If an implant prosthesis was used, prosthesis information was also recorded. Results: In total, 91 first-time failed dental implants in 77 patients were analyzed. Of them, 69 implants in 61 patients received reimplantation after failure. Sixteen patients (22 implants) refused reimplantation or received reimplantation at a different site. Eight of the 69 reimplants failed again. The 1-year survival rate of the 69 reimplants was 89.4%. Age at reimplantation and smoking significantly increased the risk of reimplantation failure. However, a history of taking anti-thrombotic agents showed a statistically significant negative association with reimplantation failure. Of the failed implants, 66% showed early failure and 34% showed late failure of the initial implantation. All 8 re-failed implants showed early failure. Only 3 of these 8 failed reimplants were re-tried and the second reimplants all survived. Conclusions: The total survival rate of implants, which included reimplants and second reimplants was 99.2%, although the survival rate of the initial implantations was 96.3%. Previous failure did not affect the success of the next trial. Reimplantation failure was more strongly affected by patient factors than by implant factors. Therefore, each patient's specific factors need to be meticulously controlled to achieve successful reimplantation.

Cochlear Implant Failure in the Pediatric Population

  • Ozer, Fulya;Yavuz, Haluk;Yilmaz, Ismail;Ozluoglu, Levent N.
    • Journal of Audiology & Otology
    • /
    • v.25 no.4
    • /
    • pp.217-223
    • /
    • 2021
  • Background and Objectives: In cochlear implant (CI) surgery, the results and causes of revision and reimplantation may guide surgeons in establishing surgical protocols for revision surgery with safe audiological outcomes. The aim of this study was to review our experience in terms of etiology, surgical strategy, and hearing outcomes in pediatric patients who underwent CI removal and reimplantation. Subjects and Methods: All patients received implants of the same brand. Pre and postoperative Categories of Auditory Performance score and aided free-field pure tone audiometry thresholds were noted. In vivo integrity tests were performed for each patient and the results of ex vivo tests of each implant were obtained from manufacturer. Results: A total of 149 CIs were placed in 121 patients aged <18 years. The revision rate in children was 6.7% (10/121 children). Six patients had a history of head injury leading to a hard failure. The causes of reimplantation in others were soft failure (n=1), electrode migration (n=1), infection (n=1), and other (n=1). All patients showed better or similar postreimplantation audiological performance compared with pre-reimplantation results. Conclusions: It is very important to provide a safe school and home environment and educate the family for reducing reimplantation due to trauma. Especially for active children, psychiatric consultation should be continued postoperatively.

Cochlear Implant Failure in the Pediatric Population

  • Ozer, Fulya;Yavuz, Haluk;Yilmaz, Ismail;Ozluoglu, Levent N.
    • Korean Journal of Audiology
    • /
    • v.25 no.4
    • /
    • pp.217-223
    • /
    • 2021
  • Background and Objectives: In cochlear implant (CI) surgery, the results and causes of revision and reimplantation may guide surgeons in establishing surgical protocols for revision surgery with safe audiological outcomes. The aim of this study was to review our experience in terms of etiology, surgical strategy, and hearing outcomes in pediatric patients who underwent CI removal and reimplantation. Subjects and Methods: All patients received implants of the same brand. Pre and postoperative Categories of Auditory Performance score and aided free-field pure tone audiometry thresholds were noted. In vivo integrity tests were performed for each patient and the results of ex vivo tests of each implant were obtained from manufacturer. Results: A total of 149 CIs were placed in 121 patients aged <18 years. The revision rate in children was 6.7% (10/121 children). Six patients had a history of head injury leading to a hard failure. The causes of reimplantation in others were soft failure (n=1), electrode migration (n=1), infection (n=1), and other (n=1). All patients showed better or similar postreimplantation audiological performance compared with pre-reimplantation results. Conclusions: It is very important to provide a safe school and home environment and educate the family for reducing reimplantation due to trauma. Especially for active children, psychiatric consultation should be continued postoperatively.

Transaxillary Capsulorrhaphy with Reimplantation to Correct Bottoming-Out Deformity in Breast Mycobacterial Periprosthetic Infection: A Case Report with Literature Review

  • Tsung-Chun Huang;Jian-Jr Lee;Kuo-Hui Yang;Chia-Huei Chou;Yu-Chen Chang
    • Archives of Plastic Surgery
    • /
    • v.50 no.6
    • /
    • pp.557-562
    • /
    • 2023
  • Augmentation mammoplasty is one of the most popular cosmetic surgeries, but there is a high reoperation rate (29.7%) commonly due to capsular contracture, implant malpositioning, infection, and unsatisfactory size. Although infection only accounts for 2% of cases, its management is very challenging, especially with nontuberculous mycobacteria (NTM) infection. Breast prosthetic NTM infection is a rare but is a disastrous condition with an incidence of approximately 0.013%. Immediate salvage reimplantation is usually not suggested, and most studies recommend a gap of 3 to 6 months after combination antibiotics therapy before reimplantation. However, delayed reimplantation often leads to great psychological stress and struggle between the doctor and patient. We present the case report of successful reimplantation in treating prosthetic NTM infections in a 28-year-old female. We discuss a novel technique "transaxillary capsulorrhaphy" to correct the bottoming-out deformity. One year after the combination of antibiotics and surgery, the follow-up computed tomography scan showed complete remission of NTM without recurrence. We discuss the surgical technique in detail. The 1-year follow-up assessment (photos and dynamic video) revealed good cosmesis and reliable correction using the new technique. This report is the first formal description and discussion of one-stage reimplantation following NTM infections. Transaxillary capsulorrhaphy allows for a successful salvage operation when an implant is displaced. This approach provides highly favorable result in eastern women undergoing revision augmentation mammoplasty. This study reflects level of evidence V, considering opinions of respected authorities based on clinical experience, descriptive studies, or reports of expert committees.

Hemodynamic Study after Left Lung Reimplantation and Right Pulmonary Artery Ligation (황견에서 좌측폐재식수술 및 우측 폐동맥결찰수술후 혈역학적 연구)

  • 홍승록
    • Journal of Chest Surgery
    • /
    • v.23 no.4
    • /
    • pp.640-645
    • /
    • 1990
  • We have performed four left lung reimplantation and right pulmonary artery ligation in dogs for six months from March 1989 to September 1989 at the Thoracic & Cardiovascular Surgery department, Yonsei University, College of Medicine, Seoul, Korea. Excised left lungs were perfused with 200cc of 4oC cold saline at a pressure of 60cmH2O through left pulmonary artery & preserved in 4 oC cold saline for about 20 mins. Left lung reimplantation were proceeded with inferior pulmonary vein, superior pulmonary vein, left pulmonary artery and left main bronchus in order. The main pulmonary artery pr. were 39/21[31], 22/12[15], 25/9[15] and 54/17[37] mmHg each after right pulmonary artery ligation on left reimplanted dogs, Right pul a. ligations were performed 9 days, 12 days, 16 days and 19 days after left lung reimplantation. Two dogs died at 10 days 21 days, after right pul. a. ligations in left reimplanted dogs. The remaining two dogs were sacrificed at 18 days, 21 days after right pul. a. ligation in left reimplanted dogs. Autopsy findings showed narrowing of left superior pul. vein anastomotic site in two narrowing of left pulmonary artery anastomotic site in one narrowing of left sup. pul vein & pneumonia of left lung in one. In the lung transplantation, it was thought to be important that the anastomosis of pulmonary artery and especially pulmonary vein be done with particular precaution for early and late stenosis.

  • PDF

Histologic Change of Extracorporeal Irradiated Autogenous Joint Transplantation in Rabbit's Knee (가토에서 체외 방사선 조사후 재이식한 자가관절의 조직학적 변화)

  • Kim, Jae-Do;Cho, Myung-Rae;Yoo, Kyung-Sik;Kim, Young-Chang
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.5 no.1
    • /
    • pp.9-16
    • /
    • 1999
  • A new method of limb sparing by resection, extracorporeal irradiation and reimplantation has several theoretical advantages. This method preserves the mobility of a joint and avoids the problem of loosening or breakage of tumor prosthesis. This study involved using extracorporeal irradiated autogenous joint transplantation for reconstruction after en bloc resection, and observed the periods of functional union and histological changes in irradiated tissue of the knee joint. This study also aimed to clarify whether the degeneration of articular cartilage is induced in rabbits by a single 50Gy dose of irradiation at the knee joint. Twenty New Zealand rabbits about three kilograms were randomized into two groups of 10 rabbits each. In group 1, as control, we resected the knee joint followed by reimplantation without irradiation. Group 2 received extracorporeal irradiation on the resected knee joint followed by reimplantation. Following are the results of these observations. The osteotomy site showed external callus formation in the roentgenographic finding eight weeks after reimplantation. There was marked degenerative changes in the collagen fiber of the irradiated anterior cruciate ligament and meniscus during the fourth week, but new blood-vessel formation was observed in the vicinity. There was degenerative changes in the collagen fiber of articular cartilage treated extracorporeal irradiation at four and eight weeks in the scanning electron micrographic findings. These findings was in contrast to those of subchondral bone which showed decreased cellularity and empty lacuna at four and eight weeks. Autoradiography demonstrated active [$^3H$]uridine incorporation by irradiated chondrocyte at eight weeks after reimplantation. These results indicate that when destruction of the articular cartilage and soft tissue of the knee joint is not severe, extracorporeal irradiation and reimplantation can be used with several advantage in maintaining movement of the joint while avoiding problems of tumor prosthesis and rejection, and therefore extracorporeal irradiated autogenous joint transplantation can be used as a limb-sparing procedure for temporary biological spacer in the childhood bone tumor around the knee.

  • PDF

Functional Outcome after Reimplantation in Patients Treated with and without an Antibiotic-Loaded Cement Spacers for Hip Prosthetic Joint Infections

  • Michele Fiore;Claudia Rondinella;Azzurra Paolucci;Lorenzo Morante;Massimiliano De Paolis;Andrea Sambri
    • Hip & pelvis
    • /
    • v.35 no.1
    • /
    • pp.32-39
    • /
    • 2023
  • Purpose: A staged revision with placement of a temporary antibiotic-loaded cement spacer after removal of the implant is the "gold standard" for treatment of chronic prosthetic joint infection (PJI). It enables local delivery of antibiotics, maintenance of limb-length and mobility, easier reimplantation. However, bacterial colonization of spacers and mechanical complications can also occur. The aim of this study is to evaluate functional results and infection control in two-stage treatment of total hip arthroplasty (THA) PJI with and without a spacer. Materials and Methods: A retrospective review of 64 consecutive patients was conducted: 34 underwent two-stage revision using a cement spacer (group A), 30 underwent two-stage revision without a spacer (group B). At the final follow-up, functional evaluation of patients with a THA in site, without PJI recurrence, was performed using the Harris hip score (HHS). Measurement of limb-length and off-set discrepancies was performed using anteroposterior pelvic X-rays. Results: Most patients in group B were older with more comorbidities preoperatively. Thirty-three patients (97.1%) in group A underwent THA reimplantation versus 22 patients (73.3%) in group B (P<0.001). No significant differences in limb-length and off-set were observed. The results of functional evaluation performed during the final follow-up (mean, 41 months) showed better function in patients in group A (mean HHS, 76.3 vs. 55.9; P<0.001). Conclusion: The use of antibiotic-loaded cement spacer seems superior in terms of functional outcomes and reimplantation rate. Resection arthroplasty might be reserved as a first-stage procedure in patients who are unfit, who might benefit from a definitive procedure.

Results with Total Replacement of the Ascending Aorta and Reimplantation of the Coronary Arteries (대동맥관 폐쇄부전을 동반한 상행대동맥의 외과적 치료)

  • Ahn, Hyuk;Rho, Joon-Ryang
    • Journal of Chest Surgery
    • /
    • v.24 no.4
    • /
    • pp.352-356
    • /
    • 1991
  • From April, 1981, to April, 1990, 20 male and 7 female patients ranging in age from 17 to 63, were operated on for aortic insufficiency with an aneurysm of the ascending aorta. Ten patients were in New York Heart Association functional class II, 7 in class III, and ten in class IV. The surgical treatment in all cases consisted of total replacement of the ascending aorta with composite graft containing a prosthetic aortic valve and reimplantation of the coronary arteries by an intermediate tube graft. In 15 patients an uncomplicated annulo-aortic ectasia existed, and in 12 an aortic dissection; three of the latter group were operated during the acute phase. 17 patients showed typical Marfan syndrome, and 3 patients showed severe ascending aortic aneurysm secondary to the aortic valve disease. The overall operative mortality was 7%[2 deaths]. Those 2 deaths occurred following emergency operation due to associated aortic dissection, but no death during elective operation. All survivors have been followed-up during a period ranging 1 to 108 month[average 34 months]. There was no late mortality. Among the survivors, clinical improvement is readily apparent[2,3 in class I, 2 in class II ]. In conclusion, the treatment of aortic insufficiency associated with an aneurysm of the ascending aorta by insertion of a composite graft and reimplantation of the coronary arteries through an intermediate Dacron tube is a reliable method with low mortality and excellent results.

  • PDF

Aortic Valve Sparing Operations: A Review

  • David, Tirone E.
    • Journal of Chest Surgery
    • /
    • v.45 no.4
    • /
    • pp.205-212
    • /
    • 2012
  • Aortic valve sparing operations were developed to preserve the native aortic valve during surgery for aortic root aneurysm as well as surgery for ascending aortic aneurysms with associated aortic insufficiency. There are basically two types of aortic valve sparing oprations: remodeling of the aortic root and reimplantation of the aortic valve. These operations have been performed for over two decades and the clinical outcomes have been excellent in experienced hands. Although remodeling of the aortic root is physiologically superior to reimplantation of the aortic valve, long-term follow-up suggests that the latter is associated with lower risk of developing aortic insufficiency. Failure of remodeling of the aortic root is often due to dilatation of the aortic annulus. Thus, this type of aortic valve sparing should be reserved for older patients with ascending aortic aneurysm and normal aortic annulus whereas reimplantation of the aortic valve is more appropriate for young patients with inherited disorders that cause aortic root aneurysms. This article summarizes the published experience with these two operations. They are no longer experimental procedures and should be part of the surgical armamentarium to treat patients with aortic root aneurysm and ascending aortic aneurysms with associated aortic insufficiency.

Arterial Switch Operation: The Technical Modification of Coronary Reimplantation and Risk Factors for Operative Death (동맥전환술: 판상돔맥이식 수기변형과 수술사망의 위험인자)

  • 성시찬;이형두;김시호;조광조;우종수;이영석
    • Journal of Chest Surgery
    • /
    • v.37 no.3
    • /
    • pp.235-244
    • /
    • 2004
  • Anatomic correction of the transposition of the great arteries (TGA) or Taussig-Bing anomaly by means of the arterial switch operation is now accepted as the therapeutic method of choice. This retrospective study was conducted to evaluate the risk factors for operative deaths and the efficacy of technical modification of the coronary transfer. 85 arterial switch operations for TGA or Taussig-Bing anomaly which were performed by one surgeon from 1994 to July 2002 at Dong-A university hospital were included in this retrospective study Multivariate analysis of perioperative variables for operative mortality including technical modification of the coronary transfer was peformed. Overall postoperative hospital mortality was 20.0% (17/85). The mortality before 1998 was 31.0% (13/42), but reduced to 9.3% (4/43) from 1998. The mortality in the patients with arch anomaly was 61.5% (8/13), but 12.5% (9/72) in those without arch anomaly. In patients who underwent an open coronary reimplantation technique, the operative mortality was 28.1% (18/64), but 4.8% (1/21) in patients undergoing a technique of reimplantation coronary buttons after neoarotic reconstruction. Risk factors for operative death from multivariated analysis were cardiopulmonary bypass time ($\geq$ 250 minutes), aortic cross-clamping time ($\geq$ 150 minutes), aortic arch anomaly, preoperative event, and open coronary reimplantation technique. Operative mortality has been reduced with time. Aortic arch anomaly and preoperative events were important risk factors for postoperative mortality. However atypical coronary artery patterns did not work as risk factors. We think that the technical modification of coronary artery transfer played an important role in reducing the postoperative mortality of arterial switch operation.