• Title/Summary/Keyword: Rehabilitation Device

Search Result 430, Processing Time 0.026 seconds

A study on the clinical usefulness, validity, and test-retest reliability of the Spirokit, a device that combines the pulmonary function test and respiratory muscle strength test

  • Kim, Byeong-Soo;Lee, Myung-Mo
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.2
    • /
    • pp.120-130
    • /
    • 2020
  • Objective: This study was conducted to identify the clinical usefulness, validity, and reliability of the Spirokit, a device that combines the pulmonary function test (PFT) and respiratory muscle strength (RMS) test. Design: Cross-sectional study. Methods: Forty young adults (male: 23, female: 17) participated in a PFT and a RMS test. The concurrent validity for pulmonary function was assessed by comparing data obtained from MicroQuark and the Spirokit and the agreements between the MicroRPM and the Spirokit for RMS were compared. The test-retest reliability of the Spirokit was determined by comparing data obtained from the first and second sessions. The test and retest were performed at the same time after one day for the PFT and RMS test. Validity was estimated using intraclass correlation coefficients (ICCs), and by calculating 95% limits of agreement (LoA). To estimate interrater reliability, ICCs were calculated. Results: The Spirokit showed a high agreement intra class coefficient (ICC [2, 1]): 0.978-0.999, 95% limits of agreements (95% LOA): -0.798 to 0.847 with MicroQuark. It also showed a high level of concordance ICC (2, 1): 0.992 to 0.993, 95% LOA: -9.313 to 11.169 with MicroRPM. The test-retest reliability of the Spirokit was analyzed using ICC (2, 1), and showed a high level of reliability (ICC [2,1]=0.960 to 0.998). Standard error of measurement % (SEM%) was 0.12% to 3.39%, and minimum detectable change% (MDC%) was 0.02% to 3.79%, indicating high level of reliability. Conclusions: The Spirokit is a device with high validity and reliability that can be used to simultaneously measure PFT and RMS tests.

Development of Device Management and Safety Diagnosis Manual for Electrical Stimulating Swallowing-Assist Equipments (전기적 자극방식 삼킴 보조 치료기의 장비관리/안전진단 매뉴얼 개발)

  • Heo, S.Y.;Choi, B.G.;Rhee, G.M.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.2
    • /
    • pp.79-88
    • /
    • 2014
  • In Republic of Korea, there are considerable vulnerability in electrical stimulating swallowing-assist equipments even though they are professional medical equipments and have high penetration rate with heavy frequency of use. Therefore, in this article, we developed Device Management and Safety Diagnosis Manual for Electrical Stimulating Swallowing-Assist Equipments system. For achieving this, we collected and analysed international standard data from international organizations like International Electrotechnical Commission(IEC). After literature reviews, we build maintenance worksheet and equipment procedure manual for electrical stimulating swallowing-assist equipments according to evidences we collected. These manual and protocol would be used as standard process and contribute to sustain accuracy, effectiveness of the devices, also decrease failure rate and assist to save medical documents.

  • PDF

Effects of Personalized Complex Aerobic Training Programs using Wearable Device on Cardiovascular and Respiratory Functions of Female Elderly

  • Song, Jun-Young;Park, Sam-Ho;Kim, Byeong-Soo;Ha, Tae-Won;Son, Jin-Kyu;Lee, Myung-Mo
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.4
    • /
    • pp.421-429
    • /
    • 2021
  • Objective: The purpose of this study was to examine the effect of personalized complex aerobic training programs using wearable device on cardiovascular and respiratory functions in community based female elderly. Design: One group pre-post intervention study. Methods: Twenty-one older female participants lived in 'D' city were included. The personalized complex aerobic training program using wearable devices was applied to all participants for 4 weeks, 3 times a week, 30 minutes for per session. The participants' blood pressure, heart rate, oxygen saturation, respiration rate, submaximal exercise stress test, pulmonary function test and respiratory muscle strength test were evaluated before and after the complex training program. Results: After intervention, resting diastolic blood pressure, resting systolic blood pressure and the systolic blood pressure after submaximal exercise stress test were significantly decreased over time (p<0.05), and the submaximal exercise stress test duration were significantly increased over time (p<0.05). The maximal inspiratory pressure (MIP) was significantly increased compare to before the intervention (p<0.05). Conclusions: This study showed that personalized complex training program using wearable device can provide personalized exercise intensity according to cardiopulmonary function that give feedback, and these interventions have a significant effect on improving the cardiovascular and respiratory system functions of the female elderly in the community dwelling.

A Study on Recognition and Activation Plan of Occupational Therapists for Community Based Rehabilitation in Pusan·Ulsan·Gyeongnam Province (부산·울산·경남 작업치료사의 지역사회중심재활에 대한 인식도 조사 및 활성화 방안)

  • Kim, Sung-Rye;Han, Seung-Hyup;Kim, Ji-Young;Park, Yong-Kwang;Lim, Ae-Jin;Han, Yun-Hee;Kam, Kyung-Yoon
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.2 no.1
    • /
    • pp.1-11
    • /
    • 2012
  • Objective : The purpose of this study was to investigate recognition and activation plan of community-based rehabilitation(CBR) by occupational therapists(OTs) in community rehabilitation center(CRC) and hospitals/clinics(HC) in Busan, Ulsan, and Gyeongnam province. Method : Frequency analysis, independent t-test and chi-squared test were performed with the SPSS 12.0 statistics package program. Result : CRC-OTs and HC-OTs were not significantly different in recognition was not significantly different in both groups. The need for involvement of OTs in CBR was very high in both groups. The suggested field for OTs in CBR were counseling for rehabilitation & information-providing, home-visiting rehabilitation, vocational rehabilitation, assistive device rental, education for disability prevention. It is required to establish CBR networking consisting of educational institutions for rehabilitation experts, local rehabilitation hospitals and clinics, and local government agencies as well as CRC and public health centers. Conclusion : CBR is recognized well by OTs in both CRC and HC and the involvement of OTs in CBR is highly needed by them. Activation plan for occupational therapy in CBR requires systemic and legal improvements.

  • PDF

Color Vision System for Intelligent Rehabilitation Robot mounted on the Wheelchair (휠체어 장착형 지능형 재활 로봇을 위한 칼라 비전 시스템)

  • Song, Won-Kyung;Lee, He-Young;Kim, Jong-Sung;Bien, Zeung-Nam
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.11
    • /
    • pp.75-87
    • /
    • 1998
  • KARES (KAIST Rehabilitation Engineering System) is the rehabilitation robot system in the type of the 6 degrees of freedom robot arm mounted on the wheelchair, in order to assist the independent livelihood of the disabled and the elderly. The interface device for programming and controlling of the robot arm is essential in the rehabilitation robotic system. Specially, in the case of the manual operation of the robot arm, the user has the burden of cognition and the difficulty for the operation of the robot arm. As a remedy, color vision system for the autonomous performance of jobs is proposed, and four basic desired jobs are specified. By mounting the camera in eye-in-hand type, color vision system for KARES is set up. The desired jobs for picking up the target and moving it to the user's face for drinking are successfully performed in real-time at the indoor environment.

  • PDF

Correlations between SPPB, FRT, and TUG in Hospitalized Frail People - The Timed Up and Go test, the Functional Reaching Test, and the Short physical performance battery - (노인요양병원 입원환자의 TUG, FRT와 SPPB와의 상관관계 연구)

  • Park, Rae-Joon;Son, Ho-Hee;Cho, Jeung-Sun;Oh, Hyen-Ju;Lee, Hyeon-Hee;Lee, Moon-Hwan;Kim, Seong-Gil
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.2
    • /
    • pp.17-21
    • /
    • 2011
  • Purpose: The purpose of this study was to determine the correlations, if any, between SPPB (Short physical performance battery), FRT (Functional reach test), and TUG (Timed up and go test) in hospitalized frail people. Methods: Seventy frail elderly patients (male/female: 16/54) participated in this study. All subjects could walk with or without an assisting device and they had no mental problems. Subjects were scored on physical functioning using the SPPB, FRT, and TUG. The data were analyzed using Pearson Correlation Coefficients. Results: There was a statistically significant difference between (a) SPPB and (b) FRT (p<0.01) and TUG (p<0.01). SPPB and FRT scores showed a positive correlation (r = 0.38) and SPPB and TUG scores showed a negative correlation (r = -0.56). Conclusion: SPPB, FRT, TUG scores are correlated with each other. From these results, we conclude that the SPPB is a useful method for predicting walking, balance, and physical function in frail elderly people.

Observation on Change of Body Temperature for Patients with Low Back Muscular Pain after Electromagnetic Theraphy: a Randomized, Patient-assessor Blind, Placebo-controlled, Pilot Trial Study (자기를 이용한 경락 자극요법 시행 후 요부근육통 환자의 체열변화 관찰: 무작위배정, 환자-평가자 눈가림, 위기기 대조군, 예비 임상 연구)

  • Cho, Woong-Hee;Park, Won-Hyung;Cha, Yun-Yeop;Sun, Seung-Ho;Lee, Seon-Goo
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.21 no.4
    • /
    • pp.145-156
    • /
    • 2011
  • Objectives: This study was resigned to observe change of body temperature for patients with low back muscular pain after NUGA MRT-II(pulsed electromagnetic therapy) treatment. Methods: This study was a randomized, patient-assessor blind, placebo-controlled, pilot trial study. After the approval of institutional review board(IRB), we have recruited 38 patients suffering from low back muscular pain and divided them into two groups randomly: the treatment group and control group. To the treatment group, NUGA MRT-II was practiced and to the control group sham device was practiced and their low back muscles and acupuncture points three times a week for 2 weeks from February 2011 to May 2011. After 1 week of last treatment, We compared body temperature of two groups. Results: 1. There was significant decrease of body temperature on both Shinsu(BL23), Chishil(BL52), Kwanwonsu(BL26) acupunture points for the treatment group. 2. There was no difference in the decrease of body temperature between treatment group and control group except. Left Kwanwonsu(BL26). Conclusions: We found out that treatment of NUGA MRT-II on low back muscular pain can reduce the temperature of low back.

Knee Rehabilitation System through EMG Signal analysis and BLDC Motor Control (근전도 신호 분석 및 BLDC모터 제어를 통한 무릎재활시스템)

  • Kwon, Hyeong-Gi;Ko, Hyeong-Gyu;Song, Yoon-Oh;Son, Eui-Seong;Lee, Boong-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.5
    • /
    • pp.1009-1018
    • /
    • 2019
  • This paper describes the design and implementation of a rehabilitation medical device based on a EMG measurement. Rehabilitation systems are controlled using BLDC motors and motor drives. The BLDC motor drive controls the operation and the speed controls the drive through the external servo motor. In addition, potentiometer coupled to the outside of the motor transmits information about the position of the load being rotated by the motor. The rehabilitation algorithm is controlled by limiting the maximum angle of 0 to 120 by utilizing the motor according to the user setting stage during the rehabilitation exercise. The walking algorithm compensates motor control for the low leg of the signal using the difference value of the signal obtained with the surface denser attached to both inner muscles. The motor and surface denser are utilized for the walk motion to control the maximum angle of 0 to 80.

Telehealth for consultation and shoulder rehabilitation: a preliminary study on the perspectives of 30 patients during the COVID-19 lockdown

  • Sahu, Dipit;Rathod, Vaibhavi;Phadnis, Ashish;Bansal, Samarjit S.
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.3
    • /
    • pp.156-165
    • /
    • 2021
  • Background: This study aimed to determine: the perspectives of the patient cohort that underwent telehealth consultation and shoulder rehabilitation during coronavirus disease 2019 (COVID-19) and the differences in the patients' perspectives with the two different telehealth video applications (apps) used in the study. Methods: This is a prospective study carried out during the COVID lockdown period of April to July 2020. Thirty consecutive patients from the orthopedics department of a tertiary institute in India underwent their first-ever session of a video app-based (Zoom or WhatsApp) telehealth consultation with shoulder rehabilitation exercises on a handheld mobile, tablet, or laptop device. After the virtual consultation, the patients were sent a validated telehealth usability questionnaire (TUQ) to evaluate their perspectives. Scores obtained from the TUQ were the primary outcome measure. Results: The study was completed by 30 patients (16 men and 14 women) with an average age of 56 years (range, 20-77 years). The patients who contacted us during the lockdown period with either a stiff shoulder or a conservatively treated shoulder fracture were included in the study. The average TUQ score was 13.6 (median, 14.5; range, 6-21) out of a maximum of 21 points. Eighty percent of the patients were satisfied and found the telehealth service useful. Use of the Zoom app scored significantly higher (median, 17; average, 15.6) than the WhatsApp app (median, 8.5; average, 9.6) (p=0.004). Conclusions: Patients who received telehealth consultation and shoulder rehabilitation were overall satisfied. Telehealth apps with advanced video calling features such as Zoom should be preferred for higher patient satisfaction.

Remote Cardiac Rehabilitation With Wearable Devices

  • Atsuko Nakayama;Noriko Ishii;Mami Mantani;Kazumi Samukawa;Rieko Tsuneta;Megumi Marukawa;Kayoko Ohno;Azusa Yoshida;Emiko Hasegawa;Junko Sakamoto;Kentaro Hori;Shinya Takahashi;Kaoruko Komuro;Takashi Hiruma;Ryo Abe;Togo Norimatsu;Mai Shimbo;Miyu Tajima;Mika Nagasaki;Takuya Kawahara;Mamoru Nanasato;Toshimi Ikemage;Mitsuaki Isobe
    • Korean Circulation Journal
    • /
    • v.53 no.11
    • /
    • pp.727-743
    • /
    • 2023
  • Although cardiac rehabilitation (CR) has been shown to improve exercise tolerance and prognosis in patients with cardiovascular diseases, there remains low participation in outpatient CR. This may be attributed to the patients' busy schedules and difficulty in visiting the hospital due to distance, cost, avoidance of exercise, and severity of coronary disease. To overcome these challenges, many countries are exploring the possibility of remote CR. Specifically, there is increasing attention on the development of remote CR devices, which allow transmission of vital information to the hospital via a remote CR application linked to a wearable device for telemonitoring by dedicated hospital staff. In addition, remote CR programs can support return to work after hospitalization. Previous studies have demonstrated the effects of remote CR on exercise tolerance. However, the preventive effects of remote CR on cardiac events and mortality remain controversial. Thus, safe and effective remote CR requires exercise risk stratification for each patient, telenursing by skilled staff, and multidisciplinary interventions. Therefore, quality assurance of telenursing and multi-disciplinary interventions will be essential for remote CR. Remote CR may become an important part of cardiac management in the future. However, issues such as cost-effectiveness and insurance coverage still persist.