• Title/Summary/Keyword: Regular Grid

Search Result 136, Processing Time 0.02 seconds

Factors Associated with Senile Macular Degeneration in Elders within Communities (지역사회거주 노인의 황반변성 관련 요인)

  • Kim, Chul-Gyu;Park, Yungeong;Park, Seungmi
    • Research in Community and Public Health Nursing
    • /
    • v.24 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • Purpose: This study was conducted to examine the degree of senile macular degeneration in elders aged 65 or older and identify factors associated with senile macular degeneration in elders within communities. Methods: Participants in this cross-sectional descriptive study were 388 elders without cataract, glaucoma, and diabetic retinopathy. Data were collected through face to face interviews using a questionnaire in an urban area from June 2010 to December 2011. To detect senile macular degeneration, the participants' self-tests were carried out with Amsler grid testing. Stepwise multivariate logistic regression was performed to evaluate the effects of health behavior and knowledge about eye health on senile macular degeneration. Results: The proportion of participants with senile macular degeneration was 11.6%. Factors that significantly increased the risk of senile macular degeneration included eye discomfort and history of ophthalmic examination (p<.05). Factors that significantly decreased the risk of senile macular degeneration included regular change of magnifiers, non-use of magnifiers, and knowledge about preventive effects of non-smoking and antioxidant vitamin intake on senile macular degeneration (p<.05). Conclusion: This study showed that programs for preventing senile macular degeneration were necessary for elders within communities and the results of this study can be used for developing those programs.

A Study on The Estimation of Partial Discharge Location Using Division of Internal Structure of Transformer and Neural Network (변압기의 내부 구조 격자화와 신경망을 이용한 부분방전 위치추정 연구)

  • Lee, Yang-Jin;Kim, Jae-Chul;Kim, Young-Sung;Cho, Sung-Min
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.370-375
    • /
    • 2006
  • This paper suggests the method for estimating a partial discharge (PD) location using divide of the inside transformer as a grid. The PD location is found swiftly and economically compared with the typical method detecting a PD. The reason is that the location of PD is detected in the section. The estimation of PD location is trained using the Neural Network. JavaNNS(Java Neural Network Simulator) and SNNS(Stuttgart Neural Network Simulator) are used for searching the location of PD. The simulation procedure is following, The transformer is assumed that the case is a regular hexahedron. The sensor is installed in a proper location. A section of PD location is set as a target, and training set is studied with several PD locations in the inside of the transformer. As a result of training process, the learning capability of neural network is excellent. The PD location is detected by division of internal structure of transformer and application of neural network.

  • PDF

Development of the Three Dimensional Landform Display Software Using the Digital Terrain Model (수치지형정보를 애용한 지형의 3차원 표현 software 개발)

  • 이규석
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.17 no.3
    • /
    • pp.1-8
    • /
    • 1990
  • The digital terrain model (DTM) or digital elevation model (DEM) is commonly used in representing the continuous variation of relief over space. One of the most frequent applications is to display the three dimensional view of the landform concerned. In this paper, the altitude matrices-regular grid cell format of the elevation in Mt. Kyeryong National Park were used in developing the three dimensional view software for the first time in Korea. It required the removal of hidden lines or surfaces. To do this, it was necessary to identify those surfaces and line segments that are visible and those that are invisible. Then, only the visible portions of the landform were displayed. The assumption that line segments are used to approximate contour surfaces by polygons was used in developing the three dimensional orthographic view. In order to remove hidden lines, the visibility test and masking algorithms were used. The software was developed in the engineering workstation, SUN 3/280 at the Institute of Space Science and Astronomy using 'C' in UNIX operating system. The software developed in this paper can be used in various fields. Some of them are as follows : (1) Landscape design and planning for identifying viewshed area(line of sight maps) (2) For planning the route selection and the facility location (3) Flight simulation for pilot training (4) Other landscape planning or civil engineering purposes

  • PDF

A Study on Regular Grid Based Real-Time Terrain LOD Algorithm for Enhancing Memory Efficiency (메모리 효율 향상을 위한 고정격자기반 실시간 지형 LOD 알고리즘에 관한 연구)

  • Whangbo Taeg-keun;Yang Young-Kyu;Moon Min-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.20 no.6
    • /
    • pp.409-418
    • /
    • 2004
  • LOD is a widely used technique in 3D game and animation to represent large 3D data sets smoothly in real-time. Most LOD algorithms use a binary tree to keep the ancestor information. A new algorithm proposed in this paper, however, do not keep the ancestor information, thus use the less memory space and rather increase the rendering performance. To verify the efficiency of the proposed algorithm, performance comparison with ROAM is conducted in real-time 3D terrain navigation. Result shows that the proposed algorithm uses about 1/4 of the memory space of ROAM and about 4 times faster than ROAM.

Numerical studies on non-linearity of added resistance and ship motions of KVLCC2 in short and long waves

  • Hizir, Olgun;Kim, Mingyu;Turan, Osman;Day, Alexander;Incecik, Atilla;Lee, Yongwon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.1
    • /
    • pp.143-153
    • /
    • 2019
  • In this study, numerical simulations for the prediction of added resistance for KVLCC2 with varying wave steepness are performed using a Computational Fluid Dynamics (CFD) method and a 3-D linear potential method, and then the non-linearities of added resistance and ship motions are investigated in regular short and long waves. Firstly, grid convergence tests in short and long waves are carried out to establish an optimal mesh system for CFD simulations. Secondly, numerical simulations are performed to predict ship added resistance and vertical motion responses in short and long waves and the results are verified using the available experimental data. Finally, the non-linearities of added resistance and ship motions with unsteady wave patterns in the time domain are investigated with the increase in wave steepness in both short and long waves. The present systematic study demonstrates that the numerical results have a reasonable agreement with the experimental data and emphasizes the non-linearity in the prediction of the added resistance and the ship motions with the increasing wave steepness in short and long waves.

Novel Maritime Wireless Communication based on Mobile Technology for the Safety of Navigation: LTE-Maritime focusing on the Cell Planning and its Verification

  • Shim, Woo-Seong;Kim, Bu-Young;Park, Chan-Yong;Lee, Byeong-Hyeok
    • Journal of Navigation and Port Research
    • /
    • v.45 no.5
    • /
    • pp.231-237
    • /
    • 2021
  • Enhancing the performance of maritime wireless communication has been highlighted by the issue of cell planning in the sea area because of lack of an appropriate Propagation Loss Model (PLM). To resolve the cell planning issue in vast sea areas, it was essential to develop the (PLM) matching the intended sea area. However, there were considerable gaps between the prediction of legacy PLMs and field measurement in propagation loss and there was a need to develop the adjusted PLM (A-PLM). Therefore, cell planning was performed on this adjusted model, including modification of the base station's location, altitude, and antenna azimuth to meet the quality objectives. Furthermore, in order to verify the availability of the cell planning, Communication Service Quality Monitoring System (CS-QMS) was developed in the LTE-Maritime project to collect LTE signal quality information from the onboard equipment at regular intervals and to ensure that the service quality was high enough to satisfy the goals in each designated grid. As a result of verification, the success rate of RSRP was 95.7% for the intensive management zone (IMZ) and 96.4% for the interested zone (IZ), respectively.

Analysis of Spatial Variability for Particle Size Distribution of Field Soils -I. Variogram (토양(土壤)의 입경분포(粒徑分布)에 대(對)한 공간변이성(空間變異性) 분석(分析) -I. Variogram)

  • Park, Chang-Seo;Kim, Jai-Joung;Cho, Seong-Jin
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.17 no.3
    • /
    • pp.212-217
    • /
    • 1984
  • Spatial variabilities of particle size distribution of 96 samples from Hwadong SiCL and Jungdong Sl were studied by using geostatistical concepts. The measurement was made at the nodes of the regular grid consisting of 12 rows and 8 columns. Sample spacing within rows and columns was 3 and 2 meters, respectively. The results are summarized as follows. 1. Variograms of Hwadong SiCL were fitted for the linear model and those of Jungdong SL for the spherical model. 2. Variograms of properties for Hwadong and clay for Jungdong showed the pure nugget effect. Those of silt and clay for Jungdong, however, appeared the nugget effect. 3. The minimum number of samples necessary to reproduce results similar to the true mean of the 96 measured values was approximately estimated. The minimum sample sizes of silt, clay, and sand in Hwadong SiCL were 27, 13, and 6, respectively. And the minimum sample size of clay in Jungdong SL was 17. 4. The approximate number of samples required to detect the difference of 5% of the true mean with 0.95 confidence level was estimated. The resulting number of samples for silt and sand in Jungdong was 14, and 26, respectively.

  • PDF

Investigation on Digital Terrain Model (수치지형모형(數値地形模型)에 관한 연구(硏究))

  • Lee, Suk Chan;Cho, Kyu Jon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.2 no.1
    • /
    • pp.93-104
    • /
    • 1982
  • DTM data evaluation regards accuracy and efficiency as its most important parameters, and these two elements are sensitively influenced by the sampling technique employed and its procedure. This study attempts to improve sampling techniques and evaluate the accuracy of DTM based on earth volume calculation, using aerial photography and field survey information as basic DTM data, and a regular grid and progressive sampling method for sampling process. Especially, the progressive sampling has employed different combinations of threshold and sampling criteria, that is, parameters influential on efficiency and accuracy, for the purpose of numerical tests intended to permit comparative analysis. The tests have resulted in the findings that in progressive sampling its grid density fits in well with given terrain characteristics in proportion to their variability. and that threshold and accuracy contain close mutual relations in which an increased threshold bringing more efficency but less accuracy. It follows, therefore. that a threshold, when appropriately determined, can be of very efficient use for considerably broad applications, and particularly, will play a significant role in its application to such general civil engineering as earth volume calculation.

  • PDF

Analysis of Spatial Variability for Infiltration Rate of Field Soil -I. Variogram (토양(土壤)중 물의 침투속도(浸透速度)의 공간변이성(空間變異性) 분석(分析) -I. Variogram)

  • Park, Chang-Seo;Kim, Jai-Joung;Cho, Seong-Jin
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.16 no.4
    • /
    • pp.305-310
    • /
    • 1983
  • Spatial variability of infiltration rates of 96 samples from Hwadong SiCL was studied by using geostatistical concepts. The measurement was made at the nodes of the regular grid consisting of 12 rows and 8 columns. Sample spacing within rows and columns was 3 and 2 meters, respectively. This study illustrated the use of variogram as a tool to identify the degree of dependency of the infiltration rate on the distance between pairs of measurements and how to take advantage of this dependency. Fractile diagram showed that the distribution of observation was approximately normal. The range of the variogram was about 7.4 meters. The minimum number of samples necessary to reproduce the results similar to the 96 measured values was 8 to 10. Coefficients of theoretical variogram function for computing kriged values and kriged varionces of nuogget effect, slope, and range were 0.444 cm/day, 0.003 cm/day, and 7.4 m, respectively.

  • PDF

A Study on Electromagnetic Compatibility Performance Evaluation of Power Conditioning System for Residential Fuel Cell (가정용 연료전지 전력변환장치 전자파적합성 성능 평가 연구)

  • Choi, Young-Joo;Nam, Tae-Ho;Lee, Eun-Kyung;Lee, Duk-Gwon;Lee, Jung-Woon;Lee, Seung-Kuk;Moon, Jong-Sam
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.6
    • /
    • pp.23-29
    • /
    • 2017
  • Solar and wind energy among the renewable energy produce irregular power because resource is difficult to control. When connected to grid have unstable. However, when the fuel cell system is connected to grid more stable because regular frequency and output power based on controllable hydrogen energy. To using fuel cell system in the household, it is important that the safety performance of power conditioning system(PCS) and it is important that evaluation method of electromagnetic compatibility(EMC). In this study, we consider that introduce power-frequency magnetic field immunity test before analyzed that compare with the EMC of the international standards and KGS AB 934 PC53. Also, we conduct that actual assessment and study on available the quantitative analysis as using complementary indicator.