• Title/Summary/Keyword: Regional ventilation

Search Result 40, Processing Time 0.023 seconds

Visual and Quantitative Assessments of Regional Xenon-Ventilation Using Dual-Energy CT in Asthma-Chronic Obstructive Pulmonary Disease Overlap Syndrome: A Comparison with Chronic Obstructive Pulmonary Disease

  • Hye Jeon Hwang;Sang Min Lee;Joon Beom Seo;Jae Seung Lee;Namkug Kim;Sei Won Lee;Yeon-Mok Oh
    • Korean Journal of Radiology
    • /
    • v.21 no.9
    • /
    • pp.1104-1113
    • /
    • 2020
  • Objective: To assess the regional ventilation in patients with asthma-chronic obstructive pulmonary disease (COPD) overlap syndrome (ACOS) using xenon-ventilation dual-energy CT (DECT), and to compare it to that in patients with COPD. Materials and Methods: Twenty-one patients with ACOS and 46 patients with COPD underwent xenon-ventilation DECT. The ventilation abnormalities were visually determined to be 1) peripheral wedge/diffuse defect, 2) diffuse heterogeneous defect, 3) lobar/segmental/subsegmental defect, and 4) no defect on xenon-ventilation maps. Emphysema index (EI), airway wall thickness (Pi10), and mean ventilation values in the whole lung, peripheral lung, and central lung areas were quantified and compared between the two groups using the Student's t test. Results: Most patients with ACOS showed the peripheral wedge/diffuse defect (n = 14, 66.7%), whereas patients with COPD commonly showed the diffuse heterogeneous defect and lobar/segmental/subsegmental defect (n = 21, 45.7% and n = 20, 43.5%, respectively). The prevalence of ventilation defect patterns showed significant intergroup differences (p < 0.001). The quantified ventilation values in the peripheral lung areas were significantly lower in patients with ACOS than in patients with COPD (p = 0.045). The quantified Pi10 was significantly higher in patients with ACOS than in patients with COPD (p = 0.041); however, EI was not significantly different between the two groups. Conclusion: The ventilation abnormalities on the visual and quantitative assessments of xenon-ventilation DECT differed between patients with ACOS and patients with COPD. Xenon-ventilation DECT may demonstrate the different physiologic changes of pulmonary ventilation in patients with ACOS and COPD.

Analysis of Working Environment and Ventilation Efficiency in Pig House using Computational Fluid Dynamics (전산유체역학을 사용한 양돈장 내 작업환경 환기효율성 분석)

  • Oh, Byung-Wook;Lee, Seong-Won;Kim, Hyo-Cher;Seo, Il-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.2
    • /
    • pp.85-95
    • /
    • 2019
  • The internal environment in pig house is closely related to the animal productivity. In addition, it is important to consider a working environment inside the pig house due to high gas and dust concentrations. The poor working environment inside the pig house can cause health problems including respiratory diseases. To analyze the working environment, it is important to evaluate the ventilation efficiency to effectively remove harmful gases and dust. The purpose of this study is to develop a 3D CFD model to analyze the working environment in the pig house. CFD model was validated by comparing air temperature distributions between CFD computed and field measured data. The average air flow rate at the pig height was 40.1 % lower than the working height when incoming air was concentrated on upper layer by the installed ventilation system on the experimental pig house. Using the validated CFD model, the regional ventilation efficiency was computed by the TGD(tracer gas decay) method at the pig and working heights. There was a difference of ventilation efficiency on 14 % between the air stagnated section and the rest sections. Stagnated gas concentration can be effected by animal and human health.

Measurements and CFD Analysis for Release Rate of CO2 and Characteristics of Natural Ventilation in Lecture Room (강의실 CO2 발생률과 자연환기 특성의 측정 및 CFD 분석)

  • Lee, Donghae;Choi, Youngbo
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.1
    • /
    • pp.86-94
    • /
    • 2021
  • Lecture rooms are crowded with many attendees. Moreover, they rely significantly on the natural ventilation through windows for removing and controlling indoor contaminants such as CO2. With the aim of broadening the understanding of the characteristics of natural ventilation phenomena in lecture rooms, the average individual CO2 release rates of attendees were measured during the course of a lecture and compared with previously reported CO2 release rates. In addition, the effects of natural ventilation through windows on the time-variant CO2 concentrations in the center of the lecture room were measured and analyzed. Moreover, details about the overall and regional CO2 concentrations, as well as the air flows in the lecture room, were simulated and analyzed with computational fluid dynamics software, Fluent 2020 R2. It was found that the average individual CO2 release rates were slightly slower than previously reported rates. The local CO2 concentrations in the lecture room for regions with a high density of attendees increased over a short period of time, although the natural ventilation was already started by opening the windows. The overall CO2 concentration in the lecture room rapidly decreased in the early stage of ventilation, but declined very slowly after a longer period of ventilation time. Therefore, in order to enhance the efficiency of a lecture room's natural ventilation, it is recommended to homogeneously distribute the attendees in the lecture room, and to frequently open the windows for short periods of time.

Radioaerosol Inhalation Imaging in Bronchial Asthma (기관지 천식의 연무흡입 폐환기스캔 소견)

  • Kim, Bum-Soo;Park, Young-Ha;Park, Jeong-Mi;Chung, Myung-Hee;Chung, Soo-Kyo;Shinn, Kyung-Sub;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.1
    • /
    • pp.46-52
    • /
    • 1991
  • Radioaerosol inhalation imaging (RII) has been used in radionuclide pulmonary studies for the past 20 years. The method is well accepted for assessing regional ventilation because of its usefulness, easy fabrication and simple application system. To evaluate its clinical utility in the study of impaired regional ventilation in bronchial asthma, we obtained and analysed RIIs in 31 patients (16 women and 15 men; age ranging 21-76 years) with typical bronchial asthma at the Department of Radiology, Kangnam St. Mary's Hospital, Catholic University Medical college, from January, 1988 to August, 1989. Scintiscans were obtained with radioaerosol produced by a BARC(Bhabha Atomic Reserch Center, India) nebulizer with 15 mCi of $^{99m}Tc-phytate$. The scanning was peformed in anterior, posterior and lateral projections following 5-minute inhalation of radioaerosol on sitting position. The scans were analyzed and correlated with the results of pulmonary function study and the findings of chest radiography. Fifteen patients had concomitant lung perfusion image with $^{99m}Tc-MAA$. Follow-up scans were obtained in 5 patients after bronchodilator therapy. The patients were divided into (1) attack type (4 patients), (2) resistant type (5 patients), (3) remittent type (10 patients) and (4) bronchitic type (12 patients). Chest radiography showed hyperinflation, altered pulmonary vascularity, thickening of the bronchial wall and accentuation of basal interstitial markings in 26 of the 31 patients. Chest radiographs were norma! in the remaining 5 patients. Regardless of type, the findings of RII were basically the same, and characterized by the deposition of radioaerosol in the central parts or in the main respiratory air ways along with mottled nonsegmental ventilation defects in the periphery. Peripheral parenchymal defects were more extensive than that of expected findings from clinical symptoms, pulmonary function test and chest radiograph. Broomstick sign was present in 17 patients. The abnormality of RII was poorly correlated with perfusion scans. In all 5 patients treated with bronchodilators, follow-up study demonstrated a decrease in the degree of radioaerosol deposition in the central air way with improved ventilation defects. This study indicates that RII is a useful technique for the evaluation of regional ventilation abnormality and the effect of treatment with bronchodilators in patients with bronchial asthma.

  • PDF

An experimental study on the performance of the separate type heat pipe in accordance with the refrigerant charge (냉매 충진량에 따른 분리형 히트파이프 성능에 관한 실험적 연구)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.1600-1604
    • /
    • 2015
  • As modern houses are constructed with high-density and high-insulation, there is benefit to reduce energy consumption, but there are many side effects raised from polluted air. To solve the problem, a ventilation system is used to improve a indoor air quality. In this research, we experimentally estimate ventilation performance of HRV(heat recovery ventilator) with heat-pipe according to working fluid filling quantity and ventilation. Heat-pipe used in this study was designated separately to be applied to a ventilation system. The working fluid was R22, which was filled from 40 to 55 (%vol.) by 5(%vol.). Ventilation based on the front velocity was measured from 0.3 m/s to 1.5 m/s by 0.3 m/s intervals. Refrigerant filling quantity with the highest efficiency was found to depend on the ventilation. From this study the optimal refrigerant filling quantity in accordance with the ventilation of the detachable heat pipes was found experimentally.

Study on the Performance of the Separate type Heat Pipe Using the Parallel Flow type Heat Exchanger (평행류형 열교환기를 이용한 분리형 히트파이프의 성능에 관한 연구)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5045-5050
    • /
    • 2015
  • As modern houses are constructed with high-density and high-insulation, there is benefit to reduce energy consumption, but there are many side effects raised from polluted air. To solve the problem, a ventilation system is used to improve a indoor air quality. In this study, we tested the parallel flow type heat exchanger used in a heat exchanger of an automotive air conditioner. And we experimentally estimate ventilation performance of HRV(heat recovery ventilator) with heat-pipe according to working fluid filling quantity and ventilation. The working fluid was R22, which was filled from 40 to 60 (%vol.) by 10(%vol.). Ventilation based on the front velocity was measured from 0.3 m/s to 1.5 m/s by 0.3 m/s intervals. Refrigerant filling quantity with the highest efficiency was found to depend on the ventilation. From this study the optimal refrigerant filling quantity in accordance with the ventilation of the detachable heat pipes was found experimentally.

Experimental Study on Developing of Double Facade System dealing with the various climatic Conditions (다양한 기후조건에 대응하는 이중외피시스템 개발에 관한 실험적 연구)

  • Lee, Keon-ho;Kim, Hyeon-soo;Jang, Dae-hee;Moon, Soo-young
    • KIEAE Journal
    • /
    • v.5 no.2
    • /
    • pp.19-26
    • /
    • 2005
  • Every site has a different given geometrical and climatic condition, which influenced not only the lifestyle of the humanbeings but also the regional architecture. For example, on a cold region, the reduction of the energy loss is necessary, like an igloo, which has a littlest energy loss at hemisphere. Or on a warm region, the house must be protected thermally from the overheating at the sunshining. like a huge shading. An architectural interpretation in the (extreme) moderate climate, like Korea, has always tried to satisfy the both opposite demands simultaneously. A facade, which divides out- and inside, has an ideal position to lead the regulated regional climatic conditions into the room. The Double Facade System(DFS) is well known as an innovative solution in the european countries, like Germany. It provides an reasonable alternative, which can achieve these goals at the same time. A Double Facade System provides an effective sunshade, which means a cooling energy reduction at the warm season. In addition, it enables a natural ventilation at the cold season with the preheating at the system as well as spring and autumn. An ordinary Single Facade System with a inside or outside sun blind provides a solution just for a specified season, like a summer or winter. But the Double Facade System can deal with the various climatic conditions in the moderate climate.

Generation of Weather Data for Future Climate Change for South Korea using PRECIS (PRECIS를 이용한 우리나라 기후변화 기상자료의 생성)

  • Lee, Kwan-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.54-58
    • /
    • 2011
  • According to the Fourth Assessment Report of the Inter governmental Panel on Climate Change(IPCC), climate change is already in progress around the world, and it is necessary to start mitigation and adaptation strategies for buildings in order to minimize adverse impacts. It is likely that the South Korea will experience milder winters and hotter and more extreme summers. Those changes will impact on building performance, particularly with regard to cooling and ventilation, with implications for the quality of the indoor environment, energy consumption and carbon emissions. This study generate weather data for future climate change for use in impacts studies using PRECIS (Providing REgional Climate for Impacts Studies). These scenarios and RCM (Regional Climate Model) are provided high-resolution climate-change predictions for a region generally consistent with the continental-scale climate changes predicted in the GCM (Global Climate Model).

  • PDF

A Study on the Performance of Ondol with a Ventilation System (환기시스템을 갖춘 온돌 성능에 관한 연구)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4047-4051
    • /
    • 2014
  • Modern apartment houses are constructed to be relatively airtight with a high heat insulation system to increase the energy efficiency. Such a system has a range of deleterious effects due to the insufficient ventilation. In this study, the ondol system, which is used as a heat source typical of winter in Korea, was set as the default system to evaluate the indoor heat environment according to the ventilation method, the factors of energy reduction by the ventilation system was analyzed. The experimental apparatus was used to simulate the ambient conditions for a certain constant temperature and humidity chamber. The experimental results showed that the supply water temperature higher air volume decreases with increasing supply air temperature in the following order: floor supply/exhaust > total heat exchange supply/exhaust > forced supply/exhaust. Through this study, the applicability of various ventilations could be examined.

Machine Learning-based Prediction of Relative Regional Air Volume Change from Healthy Human Lung CTs

  • Eunchan Kim;YongHyun Lee;Jiwoong Choi;Byungjoon Yoo;Kum Ju Chae;Chang Hyun Lee
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.2
    • /
    • pp.576-590
    • /
    • 2023
  • Machine learning is widely used in various academic fields, and recently it has been actively applied in the medical research. In the medical field, machine learning is used in a variety of ways, such as speeding up diagnosis, discovering new biomarkers, or discovering latent traits of a disease. In the respiratory field, a relative regional air volume change (RRAVC) map based on quantitative inspiratory and expiratory computed tomography (CT) imaging can be used as a useful functional imaging biomarker for characterizing regional ventilation. In this study, we seek to predict RRAVC using various regular machine learning models such as extreme gradient boosting (XGBoost), light gradient boosting machine (LightGBM), and multi-layer perceptron (MLP). We experimentally show that MLP performs best, followed by XGBoost. We also propose several relative coordinate systems to minimize intersubjective variability. We confirm a significant experimental performance improvement when we apply a subject's relative proportion coordinates over conventional absolute coordinates.