• Title/Summary/Keyword: Regional Diagnostic

Search Result 185, Processing Time 0.022 seconds

The Differentiation of Benign from Maligant Soft Tissue Lesions using FDG-PET: Comparison between Semi-quantitative Indices (FDG-PET을 이용한 악성과 양성 연부조직 병변의 감별: 반정량적 지표간의 비교)

  • Choi, Joon-Young;Lee, Kyung-Han;Choe, Yearn-Seong;Choi, Yong;Kim, Sang-Eun;Seo, Jai-Gon;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.90-101
    • /
    • 1997
  • The purpose of this study is to evaluate the diagnostic accuracy of various quantitative indices for the differentiation of benign from malignant primary soft tissue tumors by FDG-PET. A series of 32 patients with a variety of histologically or clinically confirmed benign (20) or malignant (12) soft tissue lesions were evaluated with emission whole body (5min/bed position) PET after injection of [$^{18}F$]FDG. Regional 20min transmission scan for the attenuation correction and calculation of SUV was performed in 16 patients (10 benign, 6malignant) followed by dynamic acquisition for 56min. Postinjection transmission scan for the attenuation correction and calculation of SUV was executed in the other 16 patients (10 benign, 6 malignant). The following indices were obtained. the peak and average SUV (pSUV, aSUV) of lesions, tumor-to-background ratio acquired at images of 51 min p.i. ($TBR_{51}$), tumor-to-background ratio of areas under time-activity curves ($TBR_{area}$) and the ratio between the activities of tumor ROI at 51 min p. i. and at the time which background ROI reaches maximum activity on the time-activity curves ($T_{51}/T_{max}$). The pSUV, aSUV, $TBR_{51}$, and $TBR_{area}$ in malignant lesions were significantly higher than those in benign lesions. We set the cut-off values of pSUV, aSUV, $TBR_{51},\;TBR_{area}$ and $T_{51}/T_{max}$ for the differentiation of benign and malignant lesions at 3.5, 2.8, 5.1, 4.3 and 1.55, respectively. The sensitivity, specificity and accuracy were 91.7%, 80.0%, 84.4% by pSUV and aSUV, 83.3%, 85.0%, 84.4% by $TBR_{51}$, 83.3%, 100%, 93.8% by $TBR_{area}$ and 66.7%, 70.0%, 68.8% by $T_{51}/T_{max}$. The time-activity curves did not give additional information compared to SUV or TBR. The one false negative was a case with low-grade fibrosarcoma and all four false positives were cases with inflammatory change on histology. The visual, analysis of FDG-PET also detected the metastatic lesions in malignant cases with comparable accuracy In conclusion, all pSUV, aSUV, $TBR_{51}$, and $TBR_{area}$ are useful metabolic semi-quantitative indices with good accuracy for the differentiation of benign from malignant soft-tissue lesions.

  • PDF

Usefulness in Evaluation of NM Image which It Follows in Onco. Flash Processing Application (Onco. Flash Processing 적용에 따른 핵의학 영상의 유용성 평가)

  • Kim, Jung-Soo;Kim, Byung-Jin;Kim, Jin-Eui;Woo, Jae-Ryong;Kim, Hyun-Joo;Shin, Heui-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.13-18
    • /
    • 2008
  • Purpose: The image processing method due to the algorism which is various portion nuclear medical image decision is important it makes holds. The purpose of this study is it applies hereupon new image processing method SIEMENS (made by Pixon co.) Onco. flash processing reconstruction and the comparison which use the image control technique of existing the clinical usefulness it analyzes with it evaluates. Materials & Methods: 1. Whole body bone scan-scan speed 20 cm/min, 30 cm/min & 40 cm/min blinding test 2. Bone static spot scan-regional view 200 kcts, 400 kcts for chest, pelvis, foot blinding test 3. 4 quadrant-bar phantom-20000 kcts visual evaluation 4. LSF-FWHM resolution comparison ananysis. Results: 1. Raw data (20 cm/min) & processing data (30 cm/min)-similar level image quality 2. Low count static image-image quality clearly improved at visual evaluation result. 3. Visual evaluation by quadrant bar phantom-rising image quality level 4. Resolution comparison evaluation (FWHM)-same difference from resolution comparison evaluation Conclusion: The study which applies a new method Onco. flash processing reconstruction, it will be able to confirm the image quality improvement which until high level is clearer the case which applies the method of existing better than. The new reconstruction improves the resolution & reduces the noise. This enhances the diagnostic capabilities of such imagery for radiologists and physicians and allows a reduction in radiation dosage for the same image quality. Like this fact, rising of equipment availability & shortening the patient waiting move & from viewpoint of the active defense against radiation currently becomes feed with the fact that it will be the useful result propriety which is sufficient in clinical NM.

  • PDF

Sequential Chemoradiotherapy for Stage I/II Nasal Natural Killer/T Cell Lymphoma (I/II 병기 비강 Natural Killer/T Cell 림프종에 대한 순차적 항암화학요법과 방사선치료)

  • Noh Young Joo;Ahn Yong Chan;Kim Won Seog;Ko Young Hyeh
    • Radiation Oncology Journal
    • /
    • v.22 no.3
    • /
    • pp.177-183
    • /
    • 2004
  • Purpose: Authors would report the results of sequential CHOP chemotherapy (cyclophosphamide, adriamycin, vincristine, and prednisone) and involved field radiotherapy (IFRT) for early stage nasal natural killer/T-cell Iymphoma (NKTCL). Materials and Methods: Fourteen among 17 patients, who were registered at the Samsung Medical Center tumor registry with stage I and II nasal NKTCL from March 1995 to December 1999 received this treatment protocol. Three to four cycles of CHOP chemotherapy were given at 3 weeks' interval, which was followed by local IFRT including the known tumor extent and the adjacent draining lymphatics. Results: Favorable responses after chemotherapy (before IFRT) were achievable only in seven patients (5 CR's+2 PR's: 50%), while seven patients showed disease progression. There were six patients with local failures, two with distant relapses, and none with regional lymphatic failure. The actuarial overall survival and progression-free survival at 3 years were 50.0% and 42.9%. All the failures and deaths occurred within 13 months of the treatment start. The factors that correlated with the improved survival were the absence of 'B' symptoms, the favorable response to chemotherapy and overall treatment, and the low risk by international prognostic index on univariate analyses. Conclusion: Compared with the historic treatment results by IFRT either alone or followed by chemotherapy, the current trial failed to demonstrate advantages with respect to the failure pattern and survival. Development of new treatment strategy in combining IFRT and chemotherapy is required for improving outcomes.

Clinical Usefulness of Contrast Echocardiography: The Dose Effect for Left Ventricle Visualization in Dogs (심초음파의 조영제의 임상적 유용성: 개에서 좌심영상화에 대한 조영제 용량의 영향)

  • Shin, Chang-ho;Hwang, Tae-sung;Yoon, Young-min;Jung, Dong-in;Yeon, Seong-chan;Lee, Hee-chun
    • Journal of Veterinary Clinics
    • /
    • v.32 no.6
    • /
    • pp.486-490
    • /
    • 2015
  • Two-demensional echocardiography is routinely used for evaluation of cardiac function. Visualization of the endocardial border is essential for the assessment of global and regional left ventricular with cardiac disease. SonoVue$^{TM}$ is a microbubble contrast agent that consists of sulfur hexafluoride-filled microbubbles in a phospholipid shell. There were many studies about contrast echocardiographic examination using SonoVue$^{TM}$ contrast agent, and various doses of SonoVue$^{TM}$ were used. To our knowledge, in published veterinary medicine, there was not reported for diagnostic efficient dose of SonoVue$^{TM}$ to evaluate contrast enhanced left ventricular endocardial border delineation (LVEBD). The purpose of this study is to compare the visualization time of LVEBD and find efficient dose of SonoVue$^{TM}$ for using various doses in dogs. Ten healthy Beagles were recruited to the study. Three different doses (0.03 ml/kg, 0.05 ml/kg and 0.1 ml/kg) of SonoVue$^{TM}$ were injected. Endocardial segments were assigned based on previously established methodology, where by the four-chamber views of the LV were divided into 6 segments. In this study, Contrast enhancement of the LVEBD after each injection was evaluated visually at the time point of overall contrast enhancement (Segmental scoring 5+) in the LV by three investigators in a blind manner. Statistical analysis was performed with SPSS version 14.0. All data were analyzed using one-way ANOVA, the multiple comparison Scheffe test. When data for the three offsite readers were combined, mean durations of useful contrast were $3.54({\pm}2.14)$, $6.15({\pm}2.61)$, and $24.39({\pm}11.10)$ seconds for the 0.03 ml/kg, 0.05 ml/kg, and 0.1 ml/kg SonoVue$^{TM}$ doses, respectively. After injection of contrast agent, there were no significant change in side effects such as urticaria, angioedema, hypersensitivity reactions, and digestive system disorders. This study suggests that efficient dose of SonoVue$^{TM}$ contrast agent for improvement of the left ventricle visualization is 0.1 ml/kg. The duration of useful enhancement of LVEBD and the reproducibility were also the highest at the 0.1 ml/kg dosage.

Factors that Influence Physician Salary Payment through Analyzing on Internet Invitation Webpage in Korea (초빙광고 자료를 활용한 봉직 의사의 급여수준과 관련요인)

  • Kang, Hyun Goo;Lee, Ji Hyung;Jung, Da-Doo;Lee, Moo-Sik
    • Journal of agricultural medicine and community health
    • /
    • v.46 no.1
    • /
    • pp.12-22
    • /
    • 2021
  • Backgrounds: Proper distribution and supply of physicians are factors that affect national health care systems. This study investigated the payment distribution levels and the determinants that influence the salary levels of hospital hired physicians. Methods: We analyzed 4,014 job advertisements posted on an internet invitation information site about physician recruitment from May 2016 to May 2019. We used univariate analysis to determine the relationship between average monthly salary and the other related variables. Multiple regression analysis was used to determine the predictors of physician salary level. Results: The average monthly salary for the service physician was 15.4 million won, highest for orthopedic surgeons with 22.24 million won, and lowest for diagnostic laboratory physician with 11.4 million won. The factors significantly associated with average monthly salary were; non-major specialty, housing provision, no severance pay, and incentives(p<0.05). Non-major specialty, incentives, and the regions were predictors of the average standardized monthly salary(p<0.05). Conclusion: Factors associated with average monthly salary as revealed by this study were; medical specialty, hospital regional location, housing provision, payment of retirement allowance, and payment of other incentives respectively. However, this study was a cross-sectional study, and further studies will be required.