• Title/Summary/Keyword: Region-Of-Interest

Search Result 1,500, Processing Time 0.039 seconds

Evaluation of Hemodynamic Failure with Acetazolamide Challenged $^{123}I-IMP$ Brain SEPCT and PET (PET과 Acetazolamide 부하 $^{123}I-IMP$ 뇌혈류 SPECT를 이용한 혈역학적 부전의 평가)

  • Chun, Kyung-Ah;Cho, In-Ho;Won, Kyu-Jang;Lee, Hyung-Woo;Hayashida, Kohei
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.94-102
    • /
    • 2003
  • Purpose : Cerebral blood flow (CBF) reactivity to acetazolamide (ACZ) is useful to select patients with hemodynamic failure. However, it is still a matter of speculation that varying degrees of regional CBF increases after ACZ administration represent the severity or stage of regional hemodynamic failure as assessed by positron emission tomography (PET). We studied to elucidate whether ACZ challenge $^{123}I-IMP$ brain single photon emission tomography (SPECT) can accurately grade the seventy of regional hemodynamic failure. Materials and Methods: Eighteen patients (M: 16, F: 2, average age: 61 years) with unilateral occlusive disease of the internal carotid artery or the trunk of the middle cerebral artery (MCA). Patients undewent $^{123}I-IMP$ brain SPECT study with acetazolamide challenge and PET study was carried out within 2 weeks before and after SPECT study. Five healthy volunteers with a mean age of 48 years (range: 28-73 yr, M: 3, F: 2) underwent PET studies to determine normal values. In SPECT study, an asymmetry index (Al)-the percentage of radioactivity of region of interest (ROI) in the occlusive cerebrovascular lesion to the contralateral homologous ROI-was used for numerical evaluation of relative $^{123}I-IMP$ distribution. In PET study, regional CBF, oxygen extraction fraction (OEF), cerebral metabolic rate of oxygen ($CMRO_2$) and cerebral blood volume (CBV) values were measured with $^{15}O-labeled$ gas inhalation method and the values were used for comparison with Al (Al during acetazolamide challenge-Al of basal study) on the SPECT study. ROls were classified by severity into three groups (normal, stage I and stage II). Results: Mean values of Al in areas with normal, stage I and stage II hemodynamic failure were $6.25{\pm}7.77%\;(n=107),\;-10.38{\pm}10.41%\:(n=117)\;and\;13.30{\pm}10.51%\;(n=140)$, respectively. Al significantly differed with each groups (p<0.05). Correlation between Al and CBF, OEF and CBV/CBF in hemisphere with occlusive cerebrovascular lesion was 0.20 (p<0.01), -0.28 (p<0.01) and -0.28 (p<0.01), respectively. Conclusion: We concluded that $^{123}I-IMP$ brain SPECT with acetazolamide challenge could determine the severity ad stage of regional hemodynamic failure as assessed by PET.

Prediction of Splint Therapy Efficacy Using Bone Scan in Patients with Unilateral Temporomandibular Disorder (편측성 측두하악관절장애 환자에서 골스캔을 이용한 교합안정장치 치료효과 예측)

  • Lee, Sang-Mi;Lee, Won-Woo;Yun, Pil-Young;Kim, Young-Kyun;Kim, Sang-Eun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.2
    • /
    • pp.143-149
    • /
    • 2009
  • Purpose: It is not known whether bone scan is useful for the prediction of the prognosis of patients with temporomandibular disorders(TMD). The aim of the present study was to identify useful prognostic markers on bone scan for the pre-therapeutic assessment of patients with unilateral TMD. Materials and Methods: Between January 2005 and July 2007, 55 patients(M:F=9:46; mean age, $34.7{\pm}14.1$ y) with unilateral TMD that underwent a pre-therapeutic bone scan were enrolled. Uptake of Tc-99m HDP in each temporomandibular joint(TMI) was quantitated using a $13{\times}13$ pixel-square region-of-interest over TMJ and parietal skull area as background. TMJ uptake ratios and asymmetric indices were calculated. TMD patients were classified as improved or not improved and the bone scan findings associated with each group were investigated. Results: Forty-six patients were improved, whereas 9 patients were not improved. There was no significant difference between the two groups of patients regarding the TMJ uptake ratio of the involved joint, the TMJ uptake ratio of the non-involved joint, and the asymmetric index(p>0.05). However, in a subgroup analysis, the patients with an increased uptake of Tc-99m HDP at the disease-involved TMJ, by visual assessment, could be easily identified by the asymmetric index; the patients that improved had a higher asymmetric index than the patients that did not improve($1.32{\pm}0.35$ vs. $1.08{\pm}0.04$, p=0.023), Conclusion: The Tc-99m HDP bone scan may help predict the prognosis of patients with unilateral TMD after splint therapy when the TMD-involved joint reveals increased uptake by visual assessment.

Consideration on the Satisfaction of Patients and SUV Variation According to Whether or not to Listen to Music after 18F-FDG Injection (PET/CT 검사에서 18F-FDG 투여 후 음악 청취 여부에 따른 SUV변화와 환자의 만족도에 관한 고찰)

  • Park, Suyoung;Yun, Sunhee;Kim, Hwasan;Kim, Hyunki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.37-43
    • /
    • 2013
  • Purpose: PET/CT scan using the SUV (Standardized Uptake Value) of radiopharmaceutical uptake in organs and tissues as an objective indicator makes it possible to analyze physiological and chemical reactions of human organs. This study analyzes the change of the SUV uptake in accordance with the way how PET/CT patients take a rest after the injection of $^{18}F-FDG$ (Fluororo-deoxyglucose). And also subjective satisfaction is assessed listening to music while taking a rest. Materials and Methods: From April 2011 until February 2013, Among the Primary cancer patients who admitted to the Catholic Medical Center (Seoul & Bucheon St. Mary's Hospital) and scanned $^{18}F-FDG$ PET/CT and also received care through the tracking test (mean age $55.61{\pm}12.41$ years, 108 people, 48 men and 60 women) were selected. The patients were divided into two groups. The first group (A: basal study) is requested to take a rest in bed quietly after the injection. However the second one (B: follow up study) is requested to listen to the music while taking a rest. And then SUV analysis was performed respectively. At the end of the scan, ROI (Region Of Interest) were set from the center of the liver (right lobe) and 3 spots of the brain (frontal, temporal, and occipital lobes). And the SUV was calculated. To identify the correlation among those ROIs, paired t-test was performed using SPSS software (Version 12.0K for windows, P>0.05). Also, after the PET/CT scan the satisfaction study was conducted of all the patients. 1:1 questionnaire survey was performed, and that questionnaire was made using the Likert 5-point scale. By utilizing those questionnaires, the analysis about simple frequency, percentage, average, and standard deviation was performed. Results: The SUV change of the 4 designated ROIs in accordance with listening to music was not statistically significant. (Frontal lobe P-value=0.611, Occipital lobe P-value=0.499, Temporal lobe P-value=0.717, Liver P-value=0.334: P-value>0.05) And the satisfaction study indicated that group B was appear to be 0.42 points (5 basis points) higher than group A. It showed that patients are more satisfied in group B than group A. Conclusion: when performing PET/CT scan using $^{18}F-FDG$, listening to music after the injection of the radiopharmaceuticals does not affect the SUV but given the state of the psychological comfort that may increase the patient's satisfaction.

  • PDF

The Comparison between Single Shot Turbo Spin Echo and B-FFE (Balanced Turbo Field-echo) in the Differentiation of Focal Liver Lesions (국소 간병변 감별에서 단발고속스핀에코 기법과 균형항정상 태세차를 이용한 고속영역 기법간의 비교)

  • Kim, Young-Chul;Kim, Myeong-Jin;Cha, Seung-Whan;Chung, Yong-Eun;Han, Kwang-Hyup;Choi, Jin-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.1
    • /
    • pp.39-48
    • /
    • 2007
  • Purpose : To determine the diagnostic accuracy of four different sequences : moderately T2 weighted, two heavily T2-weighted single shot turbo spin-echo sequence and breath-hold axial-2D balanced turbo field-echo sequence(bFFE) for characterization of focal lesions. Materials and Methods : During the 3-month period between June and August 2005, seventy-six patients were proved to have ninety-three focal hepatic lesions on MR imaging. The patients consisted of 49 men and 27 women (age range, 15-75 years; mean age, 56.23 years). All MR images were acquired on a 1.5-T MR using the following sequences: 1. A breath-hold axial T2-weighted single shot turbo spin-echo sequence, 2. a breath-hold axial-2D balanced turbo field-echo sequence. Two radiologists performed quantitative analysis. Another radiologist measured the lesion-to-liver contrast-to-noise ratio at the region-of-interest in the four sequences. Results : There was no significant difference in inter-observer variability between the four sequences. The accuracy for both cyst and malignancy of moderate T2 weighted MRI (echo time: 80 msec) was also highest. There was significant difference for lesion characterization between moderate T2 weighted MRI and balanced steady state procession (p-value: 0.004) in the second reader. For longer echo time, the CNR of cystic lesions were markedly increased in comparison to lesions of other component. Conclusion : The accuracy and inter-observer variability of single shot turbo spin echo T2 weighted sequence was higher than bFFE. Although there was no statically significant difference, moderate T2 weighted MRI (echo time: 80 msec) was more accurate than heavily T2 weighted sequence (echo time: 300 msec). If the results for lesion characterization is equivocal in TE 80, the addition of heavily T2 weighted MRI (echo time: 180 msec) can be helpful.

  • PDF

Study on Measurements of the Mandible BMD According to the ROI Variation (관심영역 변화에 따른 하악골 골밀도 측정에 대한 연구)

  • Tak, Jeong-Nam
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.271-276
    • /
    • 2009
  • The aim of this study was to evaluate the effect of Bone Mineral Density(BMD) at mandible. So, we studied how to measure the BMD at mandible using DEXA(Dual energy X-ray absorptiometry, DEXA) by Horner er al (1996) and knew reproducibility of the measurements. Thirty-five patients (13 men, 22 women, mean age : 25.4 years) were examined using the GE Lunar Prodigy Advance(LUNAR Corporation, madison, USA). They were examined in Semiprone position of their body and true lateral position of their mandible selected the Lumbar lateral mode. We used the custom mode in analysis when ROI (area $30{\times}2.5\;mm^2$). Three ROIs ($30{\times}2.5\;mm^2$, $50{\times}2.5\;mm^2$, $20{\times}2.5\;mm^2$) were located each at the two different sites of the mandible (angle of mandible and mental symphysis) and BMD was measured. Differences in BMD measurement was statistically compared according to the size and location of ROI. BMD was $1.320{\pm}0.358g/cm^3$ in men and was $1.152{\pm}0.340g/cm^3$ in women. BMD at the angle of mandible was $1.201{\pm}0.361g/cm^3$ in men and was $1.025{\pm}0.377g/cm^3$ in women. BMD of men at the mental symphysis was $1.434{\pm}0.341g/cm^3$ and that of women was $1.19{\pm}0.358g/cm^3$. With the ROI of $20{\times}2.5\;mm^2$, BMD was $1.262{\pm}0.384g/cm^3$ in men and was $1.113{\pm}0.357g/cm^3$ in women. With the ROI of $50{\times}2.5\;mm^2$, BMD of men was $1.320{\pm}0.358g/cm^3$ and that of women was $1.129{\pm}0.340g/cm^3$. There was a statistically significant difference of BMD according to the size and location of ROI. When measuring mandible BMD, there are good for increasing ROI and locate between ramus and mental symphysis. Especially following exam, refer to same size and location with fore exam. According to study which measure mandible BMD, It's correct to measure better a portion of mandible then whole of BMD. Using DEXA protocol is studied good for the additional study to compare the BMD at mandible. Later date, It will be good for measurement value in implant and bone graft quantitatively. Using DEXA method gain BMD threshold value in korean.

  • PDF

The Distribution and Diversity of Freshwater Fishes in Korean Peninsula (한반도 담수어류의 분포와 다양성)

  • Yoon, Ju-Duk;Kim, Jeong-Hui;Park, Sang-Hyeon;Jang, Min-Ho
    • Korean Journal of Ecology and Environment
    • /
    • v.51 no.1
    • /
    • pp.71-85
    • /
    • 2018
  • A recent topic of interest within ecology is ecosystem services that are importantly connected with biodiversity. Biodiversity is a fundamental component of ecological studies and has been the subject of many studies worldwide. However, studies on the diversity and distribution of freshwater fish were not undertaken in earnest until 2000, and the number of internationally available studies is therefore still limited. In this study, we used data from "The Survey and Evaluation of Aquatic Ecosystem Health (hereafter SEAEH)" within the framework of which whole water systems on the Korean peninsula are annually monitored to investigate and determine the current status of the diversity and distribution of freshwater fish, as well as to elucidate major factors impacting freshwater fish. A total of 130 species from 28 families were identified at around 953 sites in the SEAEH investigation of 2014. The species Zacco platypus (relative abundance: 28.2%) and Z. koreanus (19.3%) were identified as the most abundant species on the Korean peninsula, and besides these 20 endangered species, 51 endemic species and 4 exotic species were also collected. Highest (96 species) and lowest (72 species) diversity were identified in the Han River Watershed and the Yeongsan/Seomjin River Watershed, respectively. The mean endemic rate was 32.7%, which is higher than the previous rate determined in 1995. The exotic species Micropterus salmoides, Lepomis macrochirus and Carassius cuvieri were found in the whole river system except north Yeongdong, whereas Oreochromis niloticus occurred only at three sites due to the cold water temperatures in winter. Totally, 28 species were found to be translocated to different water systems not connected with known original habitats, most translocations occurring in the Nakdong River and the Yeongdong region. Among the translocated species, Opsariichthys uncirostris amurensis, and Erythroculter erythropterus were dominantly distributed in the mid- to lower reaches of Nakdong River where they may be harmful to the native fish assemblages due to their strong predation. The construction of weirs in connection with the "4 River Project" generated changes in fish assemblages before, during and after the project, resulting in altered habitat condition. Especially, a decrease in the number of endemic species and an increase in the abundance of lentic species were seen. Human-induced global warming will allow exotic species requiring high water temperatures to adapt to the environmental conditions of the Korean peninsula, which may enhance the diversity of native fishes and create changes in distribution. For the establishment of realistic and efficient management and protection strategies for Korean freshwater fish, SEAEH, which produces fundamental and quantitative data for Korean streams, is an important and necessary tool.

A Road Luminance Measurement Application based on Android (안드로이드 기반의 도로 밝기 측정 어플리케이션 구현)

  • Choi, Young-Hwan;Kim, Hongrae;Hong, Min
    • Journal of Internet Computing and Services
    • /
    • v.16 no.2
    • /
    • pp.49-55
    • /
    • 2015
  • According to the statistics of traffic accidents over recent 5 years, traffic accidents during the night times happened more than the day times. There are various causes to occur traffic accidents and the one of the major causes is inappropriate or missing street lights that make driver's sight confused and causes the traffic accidents. In this paper, with smartphones, we designed and implemented a lane luminance measurement application which stores the information of driver's location, driving, and lane luminance into database in real time to figure out the inappropriate street light facilities and the area that does not have any street lights. This application is implemented under Native C/C++ environment using android NDK and it improves the operation speed than code written in Java or other languages. To measure the luminance of road, the input image with RGB color space is converted to image with YCbCr color space and Y value returns the luminance of road. The application detects the road lane and calculates the road lane luminance into the database sever. Also this application receives the road video image using smart phone's camera and improves the computational cost by allocating the ROI(Region of interest) of input images. The ROI of image is converted to Grayscale image and then applied the canny edge detector to extract the outline of lanes. After that, we applied hough line transform method to achieve the candidated lane group. The both sides of lane is selected by lane detection algorithm that utilizes the gradient of candidated lanes. When the both lanes of road are detected, we set up a triangle area with a height 20 pixels down from intersection of lanes and the luminance of road is estimated from this triangle area. Y value is calculated from the extracted each R, G, B value of pixels in the triangle. The average Y value of pixels is ranged between from 0 to 100 value to inform a luminance of road and each pixel values are represented with color between black and green. We store car location using smartphone's GPS sensor into the database server after analyzing the road lane video image with luminance of road about 60 meters ahead by wireless communication every 10 minutes. We expect that those collected road luminance information can warn drivers about safe driving or effectively improve the renovation plans of road luminance management.

Research on the current conditions of cultural heritage management in North Korea - an example of the management of provincial sites - (북한의 문화유산 관리 현황 연구 - 지방의 유적 관리 사례를 중심으로 -)

  • Kim, Hyunwoo;Yi, Seonbok
    • Korean Journal of Heritage: History & Science
    • /
    • v.52 no.4
    • /
    • pp.4-17
    • /
    • 2019
  • Both as a means of improving North-South relations, as well as a necessary component for carrying out research on the past of the Korean peninsula, interest in North Korean cultural resources has been growing in South Korean society. As a result, studies have begun to look beyond North Korean cultural resources themselves and attempt to determine how cultural resources are managed in North Korea. Such studies have tended to investigate laws related to the management of cultural heritage in North Korea, but information gleaned from laws alone is limited. To provide a more complete picture, research must also investigate how cultural resource management laws are applied and enforced and also take into consideration aspects of cultural resource management that are not directed or regulated by law. In this study, we refer to the current National Cultural Resources Protection Laws in order to investigate systems of cultural resource management in North Korea. Furthermore, we conducted interviews with a former North Korean national who had until recently worked as a director of historical sites in North Korea. Through comparisons of information relating to organization, labor power, responsibilities, budget, and other factors of cultural resource management gained through the interviews and the 'National Cultural Resources Protection Laws,' we hoped to gain a fuller understanding of the reality of cultural resource management in North Korea. As a result, we were able to gain a better understanding of the organization and tasks related to cultural resource management and, at the same time, clarify some of the provisions that were unclear in the laws. Throughout the process, we were also able to determine that the management of cultural resources in North Korea is currently inadequate. However, because this study focuses on a specific region and is limited only to historical sites, it is difficult to generalize our findings to the entirety of cultural resource management in North Korea. In order to gain an objective and more accurate understanding of the current state of cultural resource management in North Korea, information must be collected at many levels to be synthesized and compared.

Reducing Dose in SPECT/CT Using Adaptive Statistical Iterative Reconstruction Technique (Adaptive Statistical Iterative Reconstruction 기법을 이용한 Bone SPECT/CT 검사에서 피폭량 감소 방안)

  • Choi, Jin-Wook;Choi, Hyeon-Jun;Park, Chan-Rok;Cho, Sung-Wook;Kim, Jin-Eui;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.134-139
    • /
    • 2014
  • Purpose: Adaptive statistical iterative reconstruction (ASIR) technique is a reconstruction method of CT image using statistical noise modeling which is known to reduce image noise and to preserve image quality despite reducing radiation dose. The aim of this study is to evaluate images using ASIR on bone SPECT/CT which is primarily performed in our hospital. Materials and Methods: We compared the images of applied ASIR (ASIR level: 20-80%) and none ASIR by changing the mA based on 120 kVp, 100 mA using Discovery NM/CT 670 (GE, U.S.A). First, we evaluated attenuation correction in SPECT image by changing the ASIR level using Anthropomorphic phantom. Second, we compared the contrast to noise ratio (CNR), image noise and spatial resolution in CT image using ACR phantom. Third, after selecting the ASIR level applicable patient using lower torso phantom, we examined 2 patients who followed up bone SPECT/CT and we performed blind test. Results: The degree of attenuation correction in SPECT image showed no significant difference between applied ASIR and none ASIR (P>0.05). When applied ASIR, the noise of CT image were reduced at least 17 up to 52% by changing the mA. The CNR of image with ASIR was maintained more than 0.8 at 40 mA (ASIR 60%) while those without ASIR showed 0.42 at standard 40 mA. In comparison of the high contrast object, we distinguished 12 line pairs/cm at 40 mA regardless of appling ASIR. Comparison of the patients image applied ASIR level 60% (40 mA) which found out by spine image of lower torso phantom showed no signigicant difference between applied ASIR and none ASIR in blind test. The CTDIvol and DLP for applied ASIR 60% showed decreased by 60%, 60% on average than using standard mA. Conclusion: The study show that the radiation dose in SPECT/CT using ASIR can be reduced despite degradation of SPECT and CT images. In addition, higher ASIR level could be possibly applied characteristics of SPECT/CT that region of interest is limited to bone.

  • PDF

A study for improvement of far-distance performance of a tunnel accident detection system by using an inverse perspective transformation (역 원근변환 기법을 이용한 터널 영상유고시스템의 원거리 감지 성능 향상에 관한 연구)

  • Lee, Kyu Beom;Shin, Hyu-Soung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.3
    • /
    • pp.247-262
    • /
    • 2022
  • In domestic tunnels, it is mandatory to install CCTVs in tunnels longer than 200 m which are also recommended by installation of a CCTV-based automatic accident detection system. In general, the CCTVs in the tunnel are installed at a low height as well as near by the moving vehicles due to the spatial limitation of tunnel structure, so a severe perspective effect takes place in the distance of installed CCTV and moving vehicles. Because of this effect, conventional CCTV-based accident detection systems in tunnel are known in general to be very hard to achieve the performance in detection of unexpected accidents such as stop or reversely moving vehicles, person on the road and fires, especially far from 100 m. Therefore, in this study, the region of interest is set up and a new concept of inverse perspective transformation technique is introduced. Since moving vehicles in the transformed image is enlarged proportionally to the distance from CCTV, it is possible to achieve consistency in object detection and identification of actual speed of moving vehicles in distance. To show this aspect, two datasets in the same conditions are composed with the original and the transformed images of CCTV in tunnel, respectively. A comparison of variation of appearance speed and size of moving vehicles in distance are made. Then, the performances of the object detection in distance are compared with respect to the both trained deep-learning models. As a result, the model case with the transformed images are able to achieve consistent performance in object and accident detections in distance even by 200 m.