• 제목/요약/키워드: Regenerative system

검색결과 481건 처리시간 0.033초

Performance Evaluation of Regenerative Braking System Based on a HESS in Extended Range BEV

  • Kiddee, Kunagone;Khan-Ngern, Werachet
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.1965-1977
    • /
    • 2018
  • This paper proposed a regenerative braking system (RBS) strategy for battery electric vehicles (BEVs) with a hybrid energy storage system (HESS) driven by a brushless DC (BLDC) motor. In the regenerative braking mode of BEV, the BLDC motor works as a generator. Consequently, the DC-link voltage is boosted and regenerative braking energy is transferred to a battery and/or ultracapacitor (UC) using a suitable switching pattern of the three-phase inverter. The energy stored in the HESS through reverse current flow can be exploited to improve acceleration and maintain the batteries from frequent deep discharging during high power mode. In addition, the artificial neural network (ANN)-based RBS control mechanism was utilized to optimize the switching scheme of the vehicular breaking force distribution. Furthermore, constant torque braking can be regulated using a PI controller. Different simulation and experiments were implemented and carried out to verify the performance of the proposed RBS strategy. The UC/battery RBS also contributed to improved vehicle acceleration and extended range BEVs.

전동기 구동시의 새로운 회생 제동 방법 (New regenerative braking method of motor drives.)

  • 엄주경;김재형;주성남;최기수;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 추계학술대회
    • /
    • pp.228-229
    • /
    • 2010
  • In this paper, new regenerative braking converter is proposed. And The new system is designed to be small size than conventional system. The simulation results are verified with real experimental outputs. Finally, proposed regenerative braking converter is proved to be a very excellent regeneration system in motor applications.

  • PDF

성층권비행선용 재생연료전지 시스템 요구사양 (System Requirement of Regenerative Fuel Cell for a Stratospheric Airship)

  • 정용운;이융교;강왕구;김동민;염찬홍
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.252-255
    • /
    • 2005
  • The effort to realize the concept of stratospheric airship, which can fly at about 20km altitude, has been persevered since late 1980's. Referring to the feasibility study of ensuring the flight duration of the airship over 1year, total weight is about 30 tons, the length is about 200m. There are lots of key technologies to be solved to develop the system, and one of the essential prerequisite technologies is regenerative fuel cell system. In this paper, design requirement of regenerative fuel cell system is introduced with the feasibility study results of the challenging stratospheric airship.

  • PDF

회생용 인버터의 동작개시 전압 선정을 위한 현장시험 방안 (A Scheme to Set up Starting Voltage of Regenerative Inverter)

  • 김주락;장동욱;한문섭;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.264-266
    • /
    • 2008
  • DC transit system has been adopted in the metropolitan area, Korea since 1974. EMU in this system always reiterates that acceleration and retardation. When EMU decelerates using electric breaking, regenerative power occurs. Regenerative power can be consumed in vicinity EMU on the same line or in resistor. If DC transit system has inverter for reusing regenerative power, Energy efficiency in DC transit system will be increased. This paper present a scheme to set up the starting voltage for the developed inverter and its field test result.

  • PDF

직류 지하철 급전시스템용 회생인버터 시스템 (Regeneration inverter system for DC traction system)

  • 조기현;장수진;김종윤;원충연;김용기
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.28-32
    • /
    • 2007
  • In this paper, a unified regenerative inverter and control algorithm are proposed in order to perform regenerative action and active power filter action. While the regenerative mode of traction, it works as regenerative inverter to reduce a excessive power of DC bus line and the powering mode of the traction, it works as active power filter to compensate ac current distortion, power factor, and voltage unbalance. In the paper, a regeneration inverter used PWM DC/AC inverter algorithm. And an active power filter used p-q theory. We are carrying out a mode analysis of DC traction system similar to actual system with MG-set and experimenting with prototype model. Through the simulation and experiment, we were proving the regeneration inverter operation which suggested in this paper.

  • PDF

태양열 이용 소용량 제습냉방시스템 (Small-Capacity Solar Cooling System by Desiccant Cooling Technology)

  • 이대영;권치호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.154-156
    • /
    • 2008
  • A prototype of the desiccant cooling system with a regenerative evaporative cooler was built and tested for the performance evaluation. The regenerative evaporative cooler is to cool a stream of air using evaporative cooling effect without an inc6rease in the humidity ratio. It is comprised of multiple pairs of dry and wet channels and the evaporation water is supplied only to the wet channels. By redirecting a portion of the air flown out of the dry channel into the wet channel, the air can be cooled down to a temperature lower than its inlet wet-bulb temperature at the outlet end of the dry channels. Incorporating a regenerative evaporative cooler eliminates the need for deep dehumidification in the desiccant rotor that is necessary to achieve low air temperature in the system with a direct evaporative cooler. Subsequently, the regenerative evaporative cooler enables the use of low temperature heat source to regenerate the dehumidifier permitting the desiccant cooling system more beneficial compared with other thermal driven air conditioners. At the ARI condition with the regeneration temperature of $60^{\circ}C$, the prototype showed the cooling capacity of 4.4 kW and COP of 0.75.

  • PDF

Some properties of the regenerative process

  • Shim, Donghee
    • 경영과학
    • /
    • 제14권2호
    • /
    • pp.63-68
    • /
    • 1997
  • Limiting probability in the steady state of regenerative process is one of the most useful characteristics. The formula for this limiting probability in the steady state of the regenerative process is presented in this paper. Because this formula is for the general model, it can be applied to many special systems including 2-unit redundant system. An example for this formula is also presented.

  • PDF

축열식 고온공기 연소시스템에 대한 실험적 연구 (Experimental Study on High Temperature Air Regenerative Combustion System)

  • 양병옥;임인권
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1999년도 제19회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.189-200
    • /
    • 1999
  • Combustion characteristics of a regenerative combustor for high temperature air combustion have experimentally studied. Temperature measurement on regenerative ceramic material and combustor has been carried out with changing equivalence ratio at constant turn-over period. Stable and unstable combustion region have been found and also detailed averaged temperature profile with respect to various air flow conditions have been obtained.

  • PDF

철도차량 회생에너지 활용기술별 가선 손실 저감 효과 비교 분석 연구 (Electric Power Loss Comparison Study for Regenerative Utilization Technologies in DC Electric Railway Systems)

  • 이한상;김진학;김현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1597-1598
    • /
    • 2015
  • Regenerative power utilization is one of the most interesting issue in electric railway systems. Generally, technologies to utilize regenerative power from railway vehicles are railway substation with regenerative inverter, on-station energy storage systems, and on-board energy storage systems. In this paper, the electric power loss for those technologies is calculated and compared using DC electric railway system analysis algorithm.

  • PDF

도시철도시스템의 에너지 저장방식에 관한 연구 (A Study on the Energy Storage Mass of Urban Transit System)

  • 이한민;김길동;이장무
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.831-835
    • /
    • 2007
  • Energy Saving is one of worldwide emerging issues. These days, applicable techniques of railway vehicle's regenerative energy are investigating in worldwide railway industries. Energy saving methods are "Downsizing energy loss" and "Re-utilizing kinetic energy". Useful plans for Downsizing energy loss are "adjusting operation table" and "optimizing running pattern". Furthermore, regenerative energy that is produced with decreasing speed and stoping, is an important element with reducing vehicle's weight, raising equipment 's efficiency, decreasing running resistance and re-configurating running pattern. Sustainable energy storage mass : Flywheel, EDLC(electrical double layer capacitor) and Secondary battery are applied in overseas, but these cases are not reported within the country. This research is reported for problems and economical validity that comes from by installing sustainable regenerative energy storage system in korean railway industries.

  • PDF