• 제목/요약/키워드: Refrigerator cycle

검색결과 98건 처리시간 0.024초

Cryogenic cooling system for HTS cable

  • Yoshida, Shigeru
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권2호
    • /
    • pp.1-8
    • /
    • 2017
  • Recently, Research and development activity of HTS (High Temperature Superconducting) power application is very progressive worldwide. Especially, HTS cable system and HTSFCL (HTS Fault current limiter) system are proceeding to practical stages. In such system and equipment, cryogenic cooling system, which makes HTS equipment cooled lower than critical temperature, is one of crucial components. In this article, cryogenic cooling system for HTS application, mainly cable, is reviewed. Cryogenic cooling system can be categorized into conduction cooling system and immersion cooling system. In practical HTS power application area, immersion cooling system with sub-cooled liquid nitrogen is preferred. The immersion cooling system is besides grouped into open cycle system and closed cycle system. Turbo-Brayton refrigerator is a key component for closed cycle system. Those two cooling systems are focused in this article. And, each design and component of the cooling system is explained.

터보팽창기를 이용한 2단 팽창 Claude냉동사이클 해석 (Cycle Analysis of 2-Stage Expansion Claude Refrigerator with Turboexpanders)

  • 백종훈;장호명
    • 설비공학논문집
    • /
    • 제6권2호
    • /
    • pp.130-139
    • /
    • 1994
  • A cycle analysis was performed for 2-stage expansion Claude refrigerators by a numerical method. The refrigerators are under recent development such that the reciprocating expanders of Collins cycle are replaced by new turboexpanders. A computer simulation program was written to predict the coefficient of performance of the refrigerators for several input parameters. It was found out that there exist unique optimum values for the ratio of expanded mass through the turboexpanders to the total mass and for the intermediate pressure of the 2-stage expansion. The maximum coefficient of performance was about $5{\times}10^{-4}$ at the optimal operation.

  • PDF

초전도 전력 케이블 냉각 시스템 적용을 위한 극저온 터보 팽창기 설계 및 해석 (Design and Analysis of Cryogenic Turbo Expander for HTS Power Cable Refrigeration System)

  • 이창형;김동민;양형석;김석호
    • 한국기계가공학회지
    • /
    • 제14권3호
    • /
    • pp.141-148
    • /
    • 2015
  • The cryogenic cooling system should maintain the HTS power cable below 77 K. As the length of HTS power cables has increased, there have been many efforts to develop large capacity cryocoolers. Brayton, Joule-Thomson, and Claude refrigerators were considered for the large capacity cryocooler. Among the various cryocoolers, the Brayton refrigerator is the most competitive in terms of the HTS power cable. At present, it is thought that a 10-kW class refrigerator will be able to be used as a unit cooling system for the commercialization of HTS power cables in the near future. The Brayton refrigerator is composed of recuperative heat exchangers, a compressor, and a cryogenic turbo expander. Among the various components, the cryogenic turbo expander is the part that decreases the temperature, and it is the most significant component that is closely related with overall system efficiency. It rotates at high speed using high-pressure helium or neon gas at cryogenic temperatures. This paper describes the design of a 300-W class Brayton refrigeration cycle and the cryogenic turbo expander as a downscale model for the practical 10-kW class cycle. Flow and structural analyses are performed on the rotating impeller and nozzle to verify the efficiency and the design performance.

서랍식 김치냉장고의 최적 유로 설계를 위한 유동특성에 관한 연구 (A study on flow characteristic of a stand type Kimchi refrigerator for optimum design of air flow passage)

  • 한호윤;정호윤;박영규;최윤환;이연원
    • 동력기계공학회지
    • /
    • 제15권5호
    • /
    • pp.37-42
    • /
    • 2011
  • The normal cooling system of a refrigerator is applied to indirect a cooling methods. But the Kimchi refrigerator is applied to direct the cooling method. Recently when the model was applied to both direct and indirect the cooling methods, the improvement was considerable. With the development of the living standards in Korea, there has been more sensitive dissatisfaction about the taste and the smell of Kimchi. In order to solve these kinds, there is a need to systematic and scientific approach. Based on these, the purpose of this study is to optimize design for improve the storage period of Kimchi refrigerator. In this research, we concentrate on the temperature change and heat transfer characteristics of interior parts of the Kimchi refrigerator due to control cycle of temperature and flow phenomenon of cooling air.

바이패스유로 멀티사이클을 적용한 냉동시스템의 성능특성에 관한 연구 (Performance Characteristics of a Bypass Two-Circuit Refrigeration System)

  • 김기열;정해원;김용찬
    • 설비공학논문집
    • /
    • 제21권6호
    • /
    • pp.319-325
    • /
    • 2009
  • The purpose of this study is to investigate the performance characteristics of a bypass two-circuit refrigerator. A bench scale refrigeration system was designed and constructed to estimate possible performance improvement of the bypass two-circuit refrigerator. The experiments were conducted in the bench scale refrigeration system by varying capacity of the condenser and refrigerant charge amount with an adoption of a refrigerant storage vessel. The COPs of the bypass two-circuit refrigeration system in the refrigerator and freezer (RF)-mode and freezer(F) only-mode were increased by 10% and 17%, respectively, with increasing the capacity of the condenser. Besides, the COP of the system in the F only-mode was increased by 10% by adopting the refrigerant storage vessel.

단효용 LiBr/물 흡수식 냉동사이클의 성능특성에 관한 연구 (A Study on Performance Characteristics of A Single Effect LiBr/Water Refrigeration Cycle)

  • 연제문;임삼택;오주원;이경우
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 춘계학술대회 논문집
    • /
    • pp.95-99
    • /
    • 2001
  • As a way to use energy effectively, the present study is aimed at investigating the performance characteristics of a Single Effect LiBr/Water Absorption Refrigerator using a low temperature driving heat-source. It was carried out by changing the driving heat-source temperature, the cold water outlet temperature(the refrigeration load), the cooling water inlet temperature, and the weak solution flow rate and this study compares the performance characteristics of refrigerator against the existence and non-existence of the Recirculation of the Weak solution which is used as a method to improve the performance of refrigerator. In case of Recirculation of the weak solution, more improved the Refrigeration Capacity and COP was obtained, and these effects became more larger in the high temperature of driving heat-source and large quantity of solution.

  • PDF

2 kW급 브레이튼 냉동기용 열역학 사이클 및 극저온 터보 팽창기 설계 (Design of Thermodynamic Cycle and Cryogenic Turbo Expander for 2 kW Class Brayton Refrigerator)

  • 이진우;이창형;양형석;김석호
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권2호
    • /
    • pp.299-305
    • /
    • 2016
  • 초전도 전력 케이블의 상용화 노력에 따라 점차 장선화 되면서, 단위 냉각 시스템당 냉각용량이 큰 대용량 냉동기의 필요성이 증가하고 있다. 국내에서는 극저온 냉동기에 대한 기술 부족으로 인해 현재 극저온 냉동기는 해외 선진사로부터 고가의 비용으로 수입되고 있다. 초전도 전력 케이블의 상용화를 위해서는 대용량 브레이튼 냉동기의 국내 개발이 시급하다. 대용량 브레이튼 냉동기의 구성은 복열식 열교환기, 압축기, 극저온 터보 팽창기로 구성되어 있으며, 냉동기 효율과 가장 직접적인 연관이 있는 것은 극저온 터보 팽창기이다. 극저온 터보 팽창기는 극저온에서 고속으로 회전하면서 고압의 헬륨 혹은 네온 가스를 팽창시켜 온도를 낮추는 역할을 한다. 본 논문에서는 역브레이튼 냉동 사이클을 설계하고, 이에 적합한 극저온 터보 팽창기를 설계하였다.

LCC 분석에 의한 하천수 미활용에너지 이용시스템의 경제성 평가 (Life-Cycle Analysis of the River Water Unutilized Energy System)

  • 박일환;윤형기;장기창;박준택;박성룡
    • 설비공학논문집
    • /
    • 제17권6호
    • /
    • pp.596-604
    • /
    • 2005
  • This paper presents the work on evaluating the LCC (Life-Cycle Cost) of a heat pump system as unutilized energy system. The river water as an unutilized energy source was used for the heat source of heat pump system. LCC analysis is a concrete method for evaluating the economical efficiency of energy facilities of building. The present case study shows an example of adequate use of the LCC analysis on a heat pump system and conventional gas boiler and refrigerator for building heat supply. A life cycle of 20 years was used to calculated net present value of energy cost. Over a 20 year life cycle, the energy cost could be reduced by 612 million won if a heat pump system were used instead of a conventional boiler and an absorption refrigerator.

소형 GM 냉동기를 이용한 수소 액화에 관한 시뮬레이션 연구 (A Simulation Study on the Hydrogen Liquefaction through Compact GM Refrigerator)

  • 정하늘;한단비;양원균;백영순
    • 한국수소및신에너지학회논문집
    • /
    • 제33권5호
    • /
    • pp.534-540
    • /
    • 2022
  • Liquid hydrogen has the best storage capacity per unit mass and is economical among storage methods for using hydrogen as fuel. As the demand for hydrogen increases, the need to develop a storage and supply system of liquid hydrogen is emphasizing. In order to liquefy hydrogen, it is necessary to pre-cool it to a maximum inversion temperature of -253℃. The Gifford-McMahon (GM) refrigerator is the most reliable and commercialized refrigerator among small-capacity cryogenic refrigerators, which can extract high-efficiency hydrogen through liquefied hydrogen production and boil of gas re-liquefaction. Therefore, in this study, the optimal conditions for liquefying gas hydrogen were sought using the GM cryocooler. The process was simulated by PRO/II under various cooling capacities of the GM refrigerator. In addition, the flow rate of hydrogen was calculated by comparing with specific refrigerator capacity depending on the pressure and flow rate of a refrigerant medium, helium. Simulations were performed to investigate the optimal values of the liquefaction flow rate and compression pressure, which aim for the peak refrigeration effect. Based on this, a liquefaction system can be selected in consideration of the cycle configuration and the performance of the refrigerator.