Cycle Analysis of 2-Stage Expansion Claude Refrigerator with Turboexpanders

터보팽창기를 이용한 2단 팽창 Claude냉동사이클 해석

  • Published : 1994.05.01

Abstract

A cycle analysis was performed for 2-stage expansion Claude refrigerators by a numerical method. The refrigerators are under recent development such that the reciprocating expanders of Collins cycle are replaced by new turboexpanders. A computer simulation program was written to predict the coefficient of performance of the refrigerators for several input parameters. It was found out that there exist unique optimum values for the ratio of expanded mass through the turboexpanders to the total mass and for the intermediate pressure of the 2-stage expansion. The maximum coefficient of performance was about $5{\times}10^{-4}$ at the optimal operation.

Keywords

Acknowledgement

Supported by : 한국과학재단