• Title/Summary/Keyword: Refrigeration oil

Search Result 165, Processing Time 0.028 seconds

Design of the Outlet-Port Tube of a Cyclone-Type Oil Separator for a Compressor (사이클론 방식 유분리기의 출구 튜브 설계)

  • Jang, Seongil;Ahn, Joon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.8
    • /
    • pp.402-408
    • /
    • 2015
  • A series of numerical simulations have been carried out to study the performances of cyclone-type oil separators, which are designed for refrigeration-system compressors. The corresponding working fluid is R22, which is a typical refrigerant, whereby a mineral-oil droplet is supplied (Ed-highlight-My interpretation). The outlet-tube length in relation to the total chamber volume is considered a design parameter. Depending on the tube length, the separation efficiency varies from 98.7% to 99.3%, while the predicted pressure drop is between 5.1 kPa and 6.4 kPa. Considering both the pressure drop and separation efficiency, the length of the outlet-port tube of the separator is 152 mm.

Analysis of Oil Behavior inside Upper Part of Rotary Compressor Using Visualization Technique (가시화 기법을 이용한 로터리 압축기 상부의 오일 거동 분석)

  • Cho Pil-Jae;Lee Seung-Kap;Youn Young;Ko Han Seo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.8
    • /
    • pp.772-779
    • /
    • 2005
  • An efficiency of a refrigeration cycle and a reliability of a compressor can be reduced if a refrigerant including excessive lubricating oil is exhausted from the compressor. Thus, the analysis of the oil behavior inside the compressor is required to prevent the problem. A tested rotary compressor with visualization windows has been manufactured in this study to investigate the oil behavior using developed visualization techniques. The oil behaviors at various operating conditions have been quantified to obtain the relationship with the outlet pressure inside the compressor. Also, the effect of the operating conditions on the quantity of the exhausted oil from the rotary compressor has been investigated using a manufactured test model.

Study on the Vapor Pressure and Miseibility of R-744/Mineral and POE Oil Mixture (R-744/광유 및 POE 오일 혼합물의 증기압 및 상용성에 관한 연구)

  • Choi, H.S.;Kim, S.;Park, K.K.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1672-1677
    • /
    • 2003
  • Carbon dioxide($CO_2$, R-744) has become a very popular issue in application to refrigeration and air conditioning systems as a natural refrigerant. An experimental study has been carried out to investigate the vapor pressure and miscibility of refrigerant R-744 in the presence of lubricant oil. This is of particular interest in the selection of the lubricant oil for the compressor of a refrigeration system or an air conditioning system using the refrigerant R-744. This apparatus consists of the test section, measuring devices, the vacuum pump, the constant temperature bath and relevant connecting pipes made of stainless steel. Two lubricant oils, such as mineral oil(Naphthenic) and polyol ester(POE) oil, are considered in the present study. For this purpose, test runs were conducted with the oil concentration range from 5 to 50 wt%, and the temperature range from -10 to $10^{\circ}C$ with $2^{\circ}C$ intervals. The results are correlated with the vapor pressure. and showed with the miscibility as visualization for the individual text components.

  • PDF

The Experimental Study on Uniform Distribution of Oil at the Air Conditioning System using Two Compressors (두 대의 압축기를 적용한 에어컨의 오일분배 특성에 관한 실험적 연구)

  • 김철민;황윤제;정백영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.103-108
    • /
    • 2003
  • The common accumulator was designed for solving the maldistribution problem of oil at the air conditioning system with two compressors. The oil level inside two compressors was visualized by using a common accumulator on the various operating conditions. As a result of the visualization, oil distribution inside two compressors was achieved appropriately according to the capacity of each compressor. Uniform distribution of oil was also accomplished at on and off operation condition.

A Basic Study on Selection of Refrigeration Oils for R-134a Refrigerant (R-134a 냉매용 냉동기유 선정을 위한 기초 연구)

  • Na, B.C.;An, Y.J.;Han, D.C.;Chun, K.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.439-452
    • /
    • 1994
  • One of the chlorofluorocarbon compounds. R-12 deplete atmospheric ozone. It leads to international agreement to reduce CFC production. R-134a has similar thermodynamic properties to CFC-12. It has zero ODP(Ozone Depletion Potential). This Paper focuses on the lubricating oils for using with R-134a PAGs(Polyalkylene Glycol's) and esters are primary lubricants that are now being tested for use with R-134a Because of extreme polarity of R-134a. there are many problems in the selection of lubricating oil. This investigation analyzes compressor working conditions and calculates wear parts friction for simulation testing. Miscibility and material compatibility is proved by sealed glass tests. Friction was tested on the closed type pin on disk wear tester. This equipment simulates actual refrigerating compressor. Environment controlled test made more reliable result than field test Conventional oils(mineral oils, Alkylbenzene, PAO(Polyalpha Olefin) are immiscible with R-134a. PAGs and ester oils are miscible with R-134a. Friction coefficient is similar to conventional system(mineral oil/R-12 systems) at operating condition. At start & stop condition, PAGs/R-134a system has high friction coefficient. It provide reliable result on the lubricity, miscibility, material compatibility of R-134a with these new lubricants. It suggests proper selection of refrigeration oil that may improve compressor durability of performance.

  • PDF

An Experimental Study on PAG Oil Separation Characteristics of an Oil Separator for a $CO_2$ Refrigeration system ($CO_2$ 냉동시스템의 오일 분리기에서 PAG오일 분리 특성에 관한 실험적 연구)

  • Cho, Eun-Young;Lee, Sung-Kwang;Kang, Byung-Ha;Kim, Suk-Hyun
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.271-276
    • /
    • 2008
  • The oil trap in oil separator is one of the most important characteristics for normal operation of compressor. In this study, oil separation characteristics has been investigated for $CO_2$/PAG mixture using a gravity type of oil separator. The experimental study has been carried out in the range of oil concentration 0 to 5 weight-percent and the mixture temperature range of $0^{\circ}C$ to $15^{\circ}C$. The results obtained indicate that oil separation ratio in oil separator is increased with an increase in the oil concentration and mixture temperature.

  • PDF

Prediction of Oil Lifetime due to Overheating of Oil and Bearing Housing in a Pump (펌프 베어링하우징에서 베어링과 오일의 과열 및 오일수명 예측)

  • 한상규;강병하;이봉주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.408-413
    • /
    • 2004
  • An experimental study has been carried out to investigate overheating of oil and bearing housing during pump operation. This problem is of particular interest in the pre diction of lifetime and failure of pump. Transient variation of oil temperature as well as bearing housing temperature is measured to study the effect of oil viscosity, oil amount, and discharge flow rate of pump. It is found that optimal oil quantity as well as proper viscosity of oil is required to keep the safe temperature level of oil and bearing housing in a pump. The oil temperature at steady state is almost not affected by discharge flow rate in the range of discharge flow rates considered in the present study.

Design of Oil Supply Enhancement Device for a Variable Speed Reciprocating Compressor (가변속 왕복동 압축기의 급유 촉진기구 설계)

  • 김현진;이태진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.1
    • /
    • pp.25-31
    • /
    • 2003
  • This paper addresses an oil supply enhancement device to resolve a shortage of oil supply or no oil supply at all encountered at low speed operation for a variable speed reciprocating compressor used for household refrigerators. The oil supply enhancement device comprises a moving cylinder attached to the lower end of crankshaft and two of fluid diodes, each one at the inlet and outlet of the cylinder. Up-and-down movement of the cylinder against the lower end of the crankshaft together with the functioning of the two fluid diodes produces net oil flow from oil reservoir to inside the crankshaft. The experiment on the test bench has shown that enough oil supply into the oil feeding hole cu be made by using this device even at low speed range. Some analytical study has also been carried out to under-stand its oil supply mechanism.

Experimental Study on Dispersion and Thermal Properties of Nanofluids based on POE Oil (POE 오일 나노유체의 열물성과 분산성 평가를 위한 실험적 연구)

  • Lee, K.S.;Lee, K.A.;Lee, J.S.;Lee, H.Y.;Park, S.J.;Lee, Y.S.;Kim, S.;Jang, S.P.;Kim, Jeong-Bae
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.170-177
    • /
    • 2012
  • To apply the nanofluids into the general vapor compression cycle, basically have to know the thermal properties including thermal conductivity and dynamic viscosity. And needs to show the dispersion characteristics for various nanofluids and concentrations. So, firstly this study showed experimentally the thermal properties for various concentration (0.1%~0.7%, as mass balance) and temperature($20^{\circ}C{\sim}40^{\circ}C$) on $Al_2O_3$, $TiO_2$, and CuO nanofluids using base fluid as POE oil that has used in the scroll compressor for various refrigeration system. From the results, the dynamic viscosity of nanofluids was considerably changed from the base POE oil. And, the dispersion characteristics of various nanofluids using the simple methods like as analyzing the RGB value or measuring the sinking height of nanofluids were showed experimentally. Through the results, the dispersion characteristics of $Al_2O_3$ nanofluid was better than those of $TiO_2$, and CuO nanofluids not considering the real refrigeration cycle rurming conditions.