Browse > Article

The Experimental Study on Uniform Distribution of Oil at the Air Conditioning System using Two Compressors  

김철민 (디지털 어플라이언스 연구소 에어컨 그룹)
황윤제 (디지털 어플라이언스 연구소 에어컨 그룹)
정백영 (디지털 어플라이언스 연구소 에어컨 그룹)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.15, no.2, 2003 , pp. 103-108 More about this Journal
Abstract
The common accumulator was designed for solving the maldistribution problem of oil at the air conditioning system with two compressors. The oil level inside two compressors was visualized by using a common accumulator on the various operating conditions. As a result of the visualization, oil distribution inside two compressors was achieved appropriately according to the capacity of each compressor. Uniform distribution of oil was also accomplished at on and off operation condition.