식물공장 이중창호의 하절기 열전달 성능 분석 (Performance Analysis of Summertime Heat Transfer Characteristics of the Double Skin Window for Plant Factory)

  • 소재현;김우태
    • 설비공학논문집
    • /
    • 제24권4호
    • /
    • pp.351-357
    • /
    • 2012
  • To reduce the summertime cooling load of a plant factory, a concept design was performed for the double skin window which utilizes the low temperature air from a ground coupled heat exchanger. The design parameters were selected as the number of cavity air inlet, the cavity thickness, the location of cavity air inlet, and the configuration of cavity air outlet. A parametric study was conducted in a systematic way to evaluate the heat transfer characteristics of the double skin window. As the number of cavity air inlet and the cavity thickness increase, the heat flux from outside air to indoor air was decreased. The effect of the location of cavity air inlet was not significant and the larger cavity air outlet area gave us relatively better heat blocking performance from outside hot air. This study demonstrated that it is possible to develop an improved double skin window by utilizing a ground coupled heat exchanger.

지중열교환기 설치 조건이 지중 유효 열전도도와 보어홀 열저항에 미치는 영향 (The Effects of the Installation Conditions of Ground Loop Heat Exchanger to the Thermal Conductivity and Borehole Resistance)

  • 임효재;공형진;강성재;최재호
    • 설비공학논문집
    • /
    • 제23권2호
    • /
    • pp.95-102
    • /
    • 2011
  • A ground loop heat exchanger in a ground source heat pump system is an important unit that determines the thermal performance of a system and its initial cost. A proper design requires certain site specific parameters, most importantly the ground effective thermal conductivity, the borehole thermal resistance and the undisturbed ground temperature. This study was performed to investigate the effect of some parameters such as borehole lengths, various grouting materials and U tube configurations on ground effective thermal conductivity and borehole thermal resistance. In this study, thermal response tests were conducted using a testing device to 9 different ground loop heat exchangers. From the experimental results, the length of ground loop heat exchanger affects to the effective thermal conductivity. The results of this experiment shows that higher thermal conductivity of grouting materials leads to the increase effective thermal conductivity from 22 to 32%. Also, mounting spacers have increased by 14%.

고유가 대응을 위한 신단열재 적용과 경제성평가 연구 : 공동주택을 중심으로 (Study on Application and Economic Evaluation of New Insulation Material to Confront High Oil Price: Focus on an Apartment)

  • 현종훈;김지연;박효순;최무혁
    • 설비공학논문집
    • /
    • 제20권11호
    • /
    • pp.746-751
    • /
    • 2008
  • The best plan to reduce the building energy consumption is that the insulation performance should be improved because the insulation and airtight of building envelopes have an effect on the energy consumption basically. New insulation materials, which have the high performance and are above insulation standard, have been developed steadily. Because there are not studies on the building energy rating system and economic evaluation considering new insulation materials, these matters should be studied. In result alternatives, which applied 6 high performance material each, reduce the annual heating energy and raise the building energy rating. Applying the vacuum insulation material(Case 1, 2) and vacuum or triple glazing can retrieves the investment with $120 and $140$\sim$150 per barrel each.

환기부족 구획화재의 열적 특성 (Thermal Characteristics of Under Ventilated Compartment Fire)

  • 김성찬
    • 설비공학논문집
    • /
    • 제21권1호
    • /
    • pp.41-48
    • /
    • 2009
  • The present study has been performed to investigate the thermal characteristics of under-ventilated compartment fire which is a typical fire condition in structures. A series of fire experiments was conducted to characterize the thermally driven flow in a 2/5 scale ISO 9705 fire compartment. Three different fuels were used in this test series, methane gas, heptane pool, and polystyrene pellets fire. In order to measure accurate temperature, double shield aspirated thermocouples reducing the effect of radiative energy exchange on temperature measurement were used in addition to bare bead thermocouples. The upper layer temperature for well ventilated fire was increased with increasing heat release rate, but it was slightly decreased for under-ventilated fire. The measured temperatures in the upper layer at the front sampling location were higher than at the rear. Thermal characteristics through the doorway were also analysed for a wide range of heat release rates. This study provides a comprehensive and quantitative assessment of fire behavior for under-ventilation condition of fire.

순환 공기 유량의 변화를 고려한 열펌프 건조기의 성능 해석 (Analysis on the Drying Performance with the Flow Rate of Circulation Air in a Heat Pump Dryer)

  • 이공훈;김욱중;이상열
    • 설비공학논문집
    • /
    • 제21권1호
    • /
    • pp.1-8
    • /
    • 2009
  • The simulation of a heat pump dryer has been carried out to figure out the effect of air flow rate on the drying performance represented by MER, SMER, and so on. The simulation includes the analyses of one-stage heat pump cycle and simple drying process using the drying efficiency. The heat pump cycle with Refrigerant 134a has been considered. In the dryer, some of drying air from the drying chamber flows through the heat pump system, the rest of air bypasses the heat pump system. The two air flows joins before the drying chamber inlet. The performance parameters considered in the present study are MER, SMER, the temperature and humidity of drying air. Those parameters are compared for different total air flow rate or bypass air flow rate.

공동주택 이중관 공법의 현안 분석 및 개선 연구 (A Study on the Status and Improvement of Double Pipe System in Apartment Buildings)

  • 김명석;김영일;정광섭
    • 설비공학논문집
    • /
    • 제25권1호
    • /
    • pp.37-42
    • /
    • 2013
  • Double pipe system in which PB pipe is inserted in CD pipe buried in the concrete slab is widely used for cold and hot water supplies in apartment housings. The system, however becomes complicated and the overlaying pipes in the concrete slab weaken the compressive strength of the slab. Also, insufficient insulation increases energy loss. In this work, the problems of the double pipe system are studied and plans A, B, and C are suggested for improvement. In terms of compressive strength of the concrete slab, plan A(total pipe length 73 m) was the weakest and plan B(2 m) was the strongest. Energy loss of plan A was the largest with 558.9 W and plan B was the lowest with 220.7 W. However, considering the combined effect of strength and heat loss, plan C becomes the best choice, which retains the advantage of the double pipe system.

다공튜브 오리피스 면적비 변화가 출구유동에 미치는 영향 (Effect of the Orifice Area Ratio on the Exit Flow of a Multi-Perforated Tube)

  • 이상규;이지근
    • 설비공학논문집
    • /
    • 제25권6호
    • /
    • pp.317-323
    • /
    • 2013
  • A multi-perforated tube indicates the existence of multiple holes of various shapes on the surface of a long cylinder-type or rectangular tube, and a hole installed on the surface is called an orifice, as it is relatively small in size, compared with the surface area of the tube. In this study, the flow characteristics of a circular multi-perforated tube with many orifices on the surface were investigated experimentally and numerically. The volume flowrate issuing from each orifice, discharge angle, effective flow area ratio, and the flow fields around the orifices were measured and visualized, with the variation of the orifice area ratio, at the same blockage ratio. The volume flowrate distributions along the flow direction of the multi-perforated tube tends to be more uniform, as larger orifices were positioned at the inlet side of the multi-perforated tube, compared with no orifice area change along the flow direction.

엑서지를 이용한 지역난방 열요금 제도 제안 (Suggestion for a New Exergy-Based Heat-Tariff Assessment for a District-Heating System)

  • 문정환;유호선;이재헌;문승재
    • 설비공학논문집
    • /
    • 제29권4호
    • /
    • pp.202-211
    • /
    • 2017
  • In this study, the exergy that can be reflected in the energetic and economic values was used to assess the heat tariff of a district heating (DH) system instead of the enthalpy. It is difficult to directly apply the exergy to the current heat-charge system because of the complicated calculation; therefore, the difference between the supply and return temperatures was converted to the exergy-temperature difference for the ease of the heat-amount calculation. As a result of the exergy analysis for a DH substation, the exergy-temperature difference did not affect the surrounding temperature and pressure loss. The supply temperature and the maximum difference between the supply temperature and the return temperature exerted the main effect on the exergy-temperature difference. The new heat charge of a DH user was slightly reduced in winter compared with the previous charge, but the heat charges in the other seasons are almost the same. It is concluded from the assessment of the heat tariff for which the exergy is used that this tariff is more feasible for both DH suppliers and consumers compared with enthalpy.

냉동, 냉장 시스템에서 NH3 누출 사고 시 장외영향평가를 위한 피해범위 및 대피거리 산정에 관한 연구 (Recommended Evacuation Distance for Offsite Risk Assessment of Ammonia Release Scenarios)

  • 박상욱;정승호
    • 한국안전학회지
    • /
    • 제31권3호
    • /
    • pp.156-161
    • /
    • 2016
  • An accident of an ammonia tank pipeline at a storage plant resulted in one death and three injuries in 2014. Many accidents including toxic gas releases and explosions occur in the freezing and refrigerating systems using ammonia. Especially, the consequence can be substantial due to that the large amount of ammonia is usually being used in the refrigeration systems. In this study, offsite consequence analysis has been investigated when ammonia leaks outdoors from large storages. Both flammable and toxic effects are under consideration to calculate the affected area using simulation programs for consequence analysis. ERPG-2 concentration (150 ppm) has been selected to calculate the evacuation distance out of various release scenarios for their dispersions in day or night. For offsite residential, the impact area by flammability is much smaller than that by toxicity. The methodology consists of two steps as followings; 1. Calculation for discharge rates of accidental release scenarios. 2. Dispersion simulation using the discharge rate for different conditions. This proactive prediction for accidental releases of ammonia would help emergency teams act as quick as they can.

열교환기 효율이 초저온 냉동사이클 성능에 미치는 영향 (Effect on Heat Exchangers Efficiency on Performance of Cryogenic Refrigeration Cycles)

  • 윤정인
    • 동력기계공학회지
    • /
    • 제17권4호
    • /
    • pp.58-63
    • /
    • 2013
  • This paper presents the new cascade liquefaction cycles using $CO_2-C_2H_6-N_2$ and $CO_2-N_2O-N_2$. The performance of the cascade liquefaction cycles with respect to temperature differences in the LNG heat exchangers is analyzed using HYSYS software and then compared the performance of these cycles with phillips optimized cascade liquefaction cycle. The coefficient of performance of the new liquefaction cycles considered in this study decreases with the temperature differences in the LNG heat exchangers, but the compressor work, expander work and heat capacity in the LNG heat exchanger increases, respectively. From the comparison of performance of three cycles, the cascade liquefaction cycles using $CO_2-C_2H_6-N_2$ showed the highest COP. And the cycles using $CO_2-C_2H_6-N_2$ and $CO_2-N_2O-N_2$ presented the second and third highest COP, respectively. In the view of performance, the optimized cascade liquefaction cycle using $C_3H_8-C_2H_4-C_1H_4$ yields much better COP. But, in the environment view, it is found that the cascade liquefaction cycle using $CO_2-C_2H_6-N_2$ shows favorable characteristics.