• 제목/요약/키워드: Refrigeration Effect

검색결과 850건 처리시간 0.022초

알루미늄 호일의 친수코팅 성능 개선에 관한 실험적 연구 (Experimental study on the hydrophilic performance of pre-coated aluminum foil)

  • 김영생;길용현;박환영;윤백;김자수소;김병열
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.725-732
    • /
    • 1999
  • It is usual to use hydrophilic-coated aluminum foil for evaporator fin of air-conditioners to reduce air flow resistance caused by the water droplets condensed on the fin surface. The major effect of a hydrophilic coating is to reduce the contact angle of the condensate and prevent bridging of the condensate between the adjacent fins. The performance of hydrophilic coating generally tends to be degraded as it is used since the coating material is washed down by the condensate. In the present work, several types of hydrophilic coatings were evaluated in terms of durability of hydrophilicity, corrosion resistance and heat resistance. Results showed that an improved hydrophilic coating of resin type presented superb qualify in terms of durability and corrosion resistance while having almost the same level of qualify in heat resistance compared with the others.

  • PDF

이성분 나노유체를 이용한 암모니아/물 기포 흡수기 설계 (Design of an Ammonia/water Bubble Absorber with Binary Nanofluids)

  • 김진경;김성수;강용태
    • 설비공학논문집
    • /
    • 제18권7호
    • /
    • pp.556-562
    • /
    • 2006
  • The objectives of this paper are to analyze simultaneous heat and mass transfer performance for a plate type bubble absorber with binary nanofluids numerically and to investigate the effects of binary nanofluids and surfactants on the size of the bubble absorber. The effective absorption ratio represents the effect of binary nanofluids and surfactants on the absorption performance. The kinds and concentrations of nano-particles and surfactants are considered as the key parameters. The results show that the addition of surfactants can reduce the size of absorber up to 74.4%, the application of binary nanofluids does the size up to 63.6%. Combination of binary nanofluids and surfactants can reduce the size of absorber up to 77.4%.

입구 유동 가진에 의한 사각 발열체 주위의 유동제어 및 열전달촉진 (I) 유동장 수치해석 (Flow Control and Heat Transfer Enhancement from a Heated Block by an Inflow Pulsation (I) Flow Field Computation)

  • 리광훈;김서영;성형진
    • 설비공학논문집
    • /
    • 제14권7호
    • /
    • pp.592-598
    • /
    • 2002
  • The characteristics of a pulsating flow field from a heated block representing heat-dissipating electronic component in a channel have been numerically investigated. At the channel inlet a pulsating sinusoidal flow is imposed. The Reynolds number based on the channel height (H) is fixed at Re=500, and the forcing frequency is varied in the range of $0\leqSt\leq2$. Numerical results on the time-dependent flow field are obtained and averaged over a cycle of pulsation. The effect of the important governing parameters such as the Strouhal number is investigated in detail. The results indicate that the recirculating flow behind the block is substantially affected by the pulsation frequency. To characterize the periodic vortex shedding due to the inflow pulsation, numerical flow visualizations are carried out.

입구 유동 가진에 의한 사각 발열체 주위의 유동제어 및 열전달촉진 (II) 온도장 수치해석 (Flow Control and Heat Transfer Enhancement from a Heated Block by an Inflow Pulsation (II) Thermal Field Computation)

  • 리광훈;김서영;성형진
    • 설비공학논문집
    • /
    • 제14권7호
    • /
    • pp.599-606
    • /
    • 2002
  • uniform temperature. The surfaces of the block are taken at a constant higher temperature. The channel walls are assumed to be adiabatic. Results on the time-dependent temperature field are obtained and averaged over a cycle of pulsation. The effect of the important governing parameters, such as the Strouhal number on the flow and the heat transfer is investigated in detail. The results indicate that the recirculating flow behind the block are substantially affected by the pulsation frequency. These, in turn, have a strong influence on the thermal transport from the heated element to the pulsating flow. The frequency at which the enhancement is maximum is determined.

충돌판(衝突板) 근방(近傍)에 배열(配列)된 2차원(次元) Rod가 충돌분류(衝突噴流) 열전달(熱傳達)에 미치는 영향(影響)[2]:Rod 피치변화(變化)에 대한 효과(效果) (Heat Transfer Augmentation on Flat Plate with Two-Dimensional Rods in Impinging Air Jet System[2]:Effect of rod pitch)

  • 이용화;서정윤
    • 설비공학논문집
    • /
    • 제1권2호
    • /
    • pp.182-189
    • /
    • 1989
  • The propose of this study is augmentation of heat transfer without additional external power in 2-dimensional impinging air jet. The passive heat transfer augmentation method tried in this experimental study is placement of rod bundles with the clearance, 2mm, in front of the heat transfer surface. The effects of pitch distance among rods and nozzle-to-target plate distance are investigated. The overall heat transfer rate of flat plate with rods reaches maximum at H/B=10 and P=40mm, and for H/B=2 and P=40mm the augmentation rate of heat transfer becomes maximum to a value which is about 1.57 times that of the flat plate without rods.

  • PDF

우리나라 고령토의 열전도계수에 관한 연구 (A study on the Thermal Conductivity of Kaolin in Korea)

  • 박희용;이흥주;강건
    • 설비공학논문집
    • /
    • 제1권2호
    • /
    • pp.162-172
    • /
    • 1989
  • The steady one dimensional heat flow method was used for the measurement of thermal conductivity of kaolin. The effects of the classification, density and moisture content on the thermal conductivity were studied experimentally for the 9 classes of kaolin in Korea. As the results of this study, it was found that the classification did not effect the thermal conductivity, and the conductivity increased as the density and moisture content increased. The correlation equation of the thermal conductivity as a function of the density increase rate was found and the values for the thermal conductivity as a function of moisture content were recommended.

  • PDF

습표면 조건에서 슬릿 핀-튜브 열교환기의 열전달 및 압력강하 특성 (Heat Transfer and Friction Characteristics of Slit Fin and Tube Heat Exchangers in Wet Conditions)

  • 장근선
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.1-9
    • /
    • 2007
  • Water condensate accumulated on the surface of a fin-and-tube heat exchanger significantly affects its thermal and hydraulic performance. The purpose of this study is to investigate the effect of condensate retention on the air-side heat transfer performance and flow friction. Total 12 samples of slit and plate fin-and-tube heat exchangers with varying fin spacing and number of tube rows are tested under dry and wet conditions. The thermal fluid measurements are made using a psychometric calorimeter. Frontal air velocity varies in the range from 0.7 m/s to 1.5 m/s. Using the experimental data, presented are the heat transfer coefficients in terms of Colburn j-factor and friction factor.

극저온용기 액체헬륨 표면 상부의 열전달 특성 (Heat Transfer above Liquid Helium Surface in Cryostat)

  • 최연석;김동락;신동원
    • 설비공학논문집
    • /
    • 제23권2호
    • /
    • pp.147-152
    • /
    • 2011
  • The cryogenic cooling load from the top plate of cryostat to liquid helium surface, including wall conduction, thermal radiation and current leads, is investigated in a closed cryostat system for superconducting magnet. In general methods of load estimation, individual load is calculated separately, however they are actually coupled each other because of natural convection of helium vapor. Using relevant heat transfer analysis, we calculate cryogenic load with taking into account the effect of natural convection. Cryogenic load is under-estimated approximately 1% when the natural convection is ignored. The difference between actual cooling load and cooling load by individual calculation increases with supplying current.

공조설비 운전방법 및 시설개선을 통한 에너지절약 효과분석 (An Analysis of the Energy Saving Effect Through the Retrofit and the Optimal Operation for HVAC Systems)

  • 김용기;이태원
    • 설비공학논문집
    • /
    • 제24권4호
    • /
    • pp.343-350
    • /
    • 2012
  • The major goal of building energy management is to minimize the energy consumption while maintaining the comfortable environment condition. Nowadays building energy management to save HVAC energy and so on is the most critical issue for existing building service branch with high efficiency equipments and their optimal operation. The effects on the building energy savings of the building equipment retrofit and the improvement of its operation method, especially in the field of HVAC system, were analyzed in this study for domestic small and/or medium sized buildings. Over 8.8% of energy saving was achieved compared withe total energy consumption in commercial building. These results could be used for reasonable maintenance and efficient management of the various building service equipments and related systems.

투과일사의 유입길이에 따른 Tilt 창호의 적정 기울기 산정 (The Calculation on the Optimum Angle of Tilt Type Window by Length of Transmitted Solar Radiation)

  • 조성우
    • 설비공학논문집
    • /
    • 제22권9호
    • /
    • pp.635-640
    • /
    • 2010
  • This study is suggested tilt window type to be restrained solar radiation through vertical window type in buildings. The shading and aesthetical effect of buildings would be solved by installation of tilt window type. For investigate optimum an angle of tilt window and building azimuth in reference region, the distance of transmitted solar radiation is calculated. The results of calculation showed optimum an angle of tilt window is obtained $7^{\circ}$ that the distance of transmitted solar radiation is 20% of 1.5m of balcony width. In case of an tilt window angle of $7^{\circ}$, the optimum building azimuth is showed $SW15^{\circ}{\sim}SE15$.