• Title/Summary/Keyword: Refrigeration Air-Conditioning Control System

Search Result 328, Processing Time 0.027 seconds

Simulation Study on the Performance Improvement of a $CO_2$ System Applying a Two-stage Phase-separate Cycle (2단압축 상분리 사이클을 적용한 이산화탄소 시스템의 성능향상에 관한 해석적 연구)

  • Ryu Chang-Gi;Lee Ho-Seong;Kim Yong-Chan;Cho Hong-Hyun;Cho Sung-Wook
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.8
    • /
    • pp.641-648
    • /
    • 2006
  • In this study, a two-stage phase-separate cycle was investigated analytically to improve the performance of the $CO_2$ system in the cooling mode. The simulation results were verified with the measured data. The predictions using the simulation model were consistent with the measured data within ${\pm}20%$ deviations. The performance of the modified $CO_2$ system with the two-stage phase-separated cycle was analyzed with the variations of outdoor temperature and EEV opening. The cooling COP decreased with the increase of compressor frequency. The highest COP was 2.7 at compressor frequencies of 30 Hz and 30 Hz for the first and second compressors, respectively. In addition, the cooling COP increased by 9.3% with an application of optimum control of the first and second-stage EEV openings.

A Development of the On-line Maintenance and Management System for the HVAC Systems and the Evaluation of Its Effects (공조설비 온라인 유지관리시스템 개발 및 효과분석)

  • Lee, Tae-Won;Kim, Yong-Ki;Woo, Nam-Sub
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.11
    • /
    • pp.591-598
    • /
    • 2009
  • The service quality with the various building equipments tends to depend on the individual superintendent's capability and efforts generally and this often lead to poor maintenances and managements of them. N-BMS(Networked Building Management System), proposed in this study, is a new type of building management method, which links principal equipments within many buildings into a communication network and carries out several significant missions such as fault detection, deterioration diagnosis and control the equipments and so on, as well as monitoring which is the main and unique purpose of the conventional BMS. How to construct the N-BMS was considered to keep performance of equipments high and thus to save energy and resource. LCC(Life Cycle Cost) based analysis was also performed in order to verify the effects of some maintenance and management works for the building HVAC systems.

An Experimental Study on the Cooling Characteristics of an Infrared Detector Cryochamber (적외선 센서용 극저온 용기의 냉각특성에 관한 실험적 연구)

  • Kang Byung Ha;Lee Jung Hoon;Kim Ho-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.889-894
    • /
    • 2004
  • Infrared (IR) detectors are widely used for many applications, such as temperature measurement, intruder and fire detection, robotics and industrial equipment, thermoelstic stress analysis, medical diagnostics, and chemical analysis. Quantum detectors commonly need to be refrigerated below 80 K, and thus a cooling system should be equipped together with the detector system. The cooling load, which should be removed by the cooling system to maintain the nominal operating temperature of the detector, critically depends on the insulation efficiency of the cryochamber housing the detector. Thermal analysis of cryochamber includes the conduction heat transfer through a cold well, the gases conduction and gas outgassing, as well as radiation heat transfer, The transient cooling characteristics of an infrared detector cryochamber are investigated experimentally in the present study. The transient cooling load increases as the gas pressure is increased. Gas pressure becomes significant as the cooling process proceeds. Cool down time is also increased as the gas pressure is increased. It is also found that natural convection effects on cool down time become significant when the gas pressure is increased.

Antibacterial Characteristics of Silver Nano-Particles Attached to Activated Carbon Filter (은나노를 부착한 활성탄 필터의 제균특성)

  • Heo, Ju-Yeong;Nam, Sang-Yeob;Kang, Jeong-Hee;Song, Ji-Hyeon;Kang, Byung-Ha;Han, Sung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.10
    • /
    • pp.583-589
    • /
    • 2009
  • Activated carbon has long been used in purification processes for indoor air quality. However, the bioaerosol removal by activated carbon is not often sufficient to be used in an air control devise. In order to overcome these problems, silver nano-particles have been proposed as an antibacterial agent on the surface of activated carbon. Silver or silver ions have been known for antimicrobial activities. In this study, bioaerosol generated by using an Escherichia coli culture was introduced to a lab-scale column packed with activated carbon (AC) and silver nano-particles attached to activated carbon (Ag-AC). E. coli was almost completely removed in the Ag-AC column, whereas bioaerosol penetrated through the AC column. To determine the antibacterial effect of different filter materials in a full-scale air-handling system, another experiment was conducted using a wind tunnel equipped with a heat exchanger and three filter materials including commercial fabric, AC and Ag-AC. It was found that E. coli proliferated on the surface of the heat exchanger after 5 days, which dramatically increased bioaerosol counts in the effluent air stream. The fabric filter could not control the increased bioaerosol and most of the E. coli penetrated the filter. The bacterial removal efficiency was found to be approximately 45% in the AC filter, while the antibacterial efficiency increased to 70% using the Ag-AC filter. Consequently, the Ag-AC filter can be an effective method to control bioaerosol and improve indoor air quality.

Numerical Study on Control Factors of Defrosting Performance for Automobile Windshield Glass in Winter (수치해석을 통한 자동차 전면유리 제상성능 제어인자 연구)

  • Youn, Young-Muk;Kader, Md. Faisal;Lee, Kum-Bae;Jun, Yong-Du
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.789-794
    • /
    • 2008
  • Recently, much attention has been paid in the field of defrosting because clear windshield in vehicle without effecting the thermal comfort is realized essentially. Then in winter, defrosting performance is one of the important factors in vehicle design to make certain driver's view. In this study, the velocity profile, temperature distribution and frost melting pattern on the windshield screen have been predicted in three dimensional geometry of an automobile interior. Numerical analyses predict a detailed description of fluid flow and temperature patterns on the inside windshield screen, utilizing the flow through defroster nozzle. Numerical prediction established a good defrosting performance with the standard distance ratio and the defroster nozzle angle ranging from $30^{\circ}$ to $40^{\circ}$, which satisfy the condition of National Highway Traffic Safety Administration (NHTSA) completely.

Improvement of Conventional Sliding Mode Observer for Full Range Sensorless Control of a PMSM

  • Wibowo, Wahyu Kunto;Jeong, Seok-Kwon
    • Journal of Power System Engineering
    • /
    • v.19 no.4
    • /
    • pp.89-96
    • /
    • 2015
  • This paper investigates some strategies to overcome the chattering problem of the conventional sliding mode observer (SMO) and to improve the rotor position estimation performance for full range sensorless control of a PMSM. An adaptive observer gain based on the Lyapunov's stability criterion and a cascade low pass filter with advanced phase delay compensation were proposed to reduce the chattering problem and to strengthen the filtering capability of the SMO. Several cases studies through experiments were carried out to confirm conventional SMO's problems and effectiveness of the proposed strategies. The experimental results show that the proposed method gives precise estimation on speed and rotor position when the motor rotates on 2% of its rated speed.

The 1D-3D Simulation for Smoke Ventilation in a Rescue Station of a Railroad Tunnel under the Fire (장대 터널 내 구난역의 열차 화재 시 제연을 위한 1D-3D 연계 해석)

  • Jung, Jae-Hyuk;Hur, Nahm-Keon;Lee, Jung-Pyo;Kim, Jin-Kon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.10
    • /
    • pp.665-671
    • /
    • 2010
  • In the present study a 1D-3D numerical simulation was performed to analyze the fire safety in a rescue station of a long railroad tunnel equipped with a mechanical ventilation. The behavior of hot air was studied for the emergency operation mode of ventilation system in case of fire in the rescue station. The 1D simulation was carried out for entire tunnel region. Detailed 3D CFD simulation was performed for the rescue station area in the central region of the tunnel by using the result of the 1D simulation as the boundary condition of the 3D simulation. Various type of cross passage installation were evaluated for the prevention of smoke diffusion to suggest the optimized interval of the cross passages in the rescue tunnel.

Evaluation of Indoor Environment Characteristics through Field Measurement in Large-sized Discount Stores (현장측정을 통한 대형 할인매장의 실내환경 평가)

  • Park Byung-Yoon;Jung Yong-Ho;Ham Heung Don;Sohn Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.9
    • /
    • pp.863-872
    • /
    • 2005
  • It is important to control indoor environment for influence on health and comfort of occupants in large-sized discount stores. On the other hand large-sized discount stores have a large number of visitors, vestibules, open spaces, high energy consumption and increasing of outside air intake. This study aims to offer the design data of building services system that can save energy and control environment through field measurement selecting two large-sized discount stores. Indoor environment factors such as temperature, relative humidity, air velocity and concentrations of $CO_2$, CO gas and TSP were measured and evaluated. In each case of $CO_2$, and CO gas, its maximum values were 2,800 ppm and 20 ppm. So proper strategy for the indoor air quality is indispensable in this type of building. Dry bulb temperature varies from $18^{\circ}C$ to $28^{\circ}C$ according to a measuring point and time. From this results, it is inferred these buildings had excessive equipment capacity. In terms of economical and environmental points, these data will be utilized to the design of HVAC system of retail facilities.

A Study on the Transient Measurement of the Effective Thermal Diffusivity of Insulation Materials by NPE Method (NPE법을 이용한 절연재료의 유효열확산계수의 과도측정에 관한 연구)

  • Lim, Dong Joo;Bae, Sin Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.3
    • /
    • pp.243-255
    • /
    • 1990
  • The objective of this study is to present an efficient measurement method of the effective thermal diffusivity for the fibrous insulation material. The non-linear parameter estimation (NPE) method is adapted for this analysis because of its accuracy and its results are compared with those by other direct methods such as CTP, CHP and STD method. A experimental system is constructed with bell-jar vaccum chamber, diffusion pump, tube type furnace, control unit and data acquisition system included with A/D converter and IBM XT/AT personal computer. The typical results obtained from this study are as follows; 1) NPE method can be recommended as an useful and accurate method to measure the effective thermal diffusivity of insuation material because it is shown that the measurement error compared with those by other direct methods is reduced for standard material, NBS-1450b. 2) NPE method can minimize the effects of ill-measured temperature due to external disturbance, because the final value is found by point to point estimating. 3) NPE method dose not depend on the kinds of heat flux, since the surfac temperature are used to estimate the thermal diffusivity. 4) With NPE method, compared with the steady state method, a measuring time and a sample size could be reduced.

  • PDF

An Experimental Study on the Optimal Intermediate Pressure of a 2-Stage Compression Heat Pump Using River Water (하천수 열원 2단압축 열펌프의 최적 중간압에 관한 실험적 연구)

  • Park, Cha-Sik;Jung, Tae-Hun;Joo, Young-Ju;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.6
    • /
    • pp.333-339
    • /
    • 2009
  • The objective of this study is to predict optimal intermediate pressure of a 2-stage compression heat pump system using river water. To determine the maximum performance of the 2-stage compression heat pump system, the experimental evaluations on the 2-stage compression cycle were carried out under various operating conditions. Electronic expansion valves were applied to control intermediate pressure and superheat. Based on the experimental data, an empirical correlation for predicting optimal intermediate pressure which considering cycle operating parameters was developed. The present correlation was verified by comparing the predicted data with the measured data. The predictions showed a good agreement with the measured data within a relative deviation of ${\pm}4%$ at various operating conditions.