Browse > Article

The 1D-3D Simulation for Smoke Ventilation in a Rescue Station of a Railroad Tunnel under the Fire  

Jung, Jae-Hyuk (Graduate school, Sogang University)
Hur, Nahm-Keon (Department of Mechanical Engineering, Sogang University)
Lee, Jung-Pyo (Graduate school, Korea Aerospace University)
Kim, Jin-Kon (Department of Aerospace and Mechanical Engineering, Korea Aerospace University)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.22, no.10, 2010 , pp. 665-671 More about this Journal
Abstract
In the present study a 1D-3D numerical simulation was performed to analyze the fire safety in a rescue station of a long railroad tunnel equipped with a mechanical ventilation. The behavior of hot air was studied for the emergency operation mode of ventilation system in case of fire in the rescue station. The 1D simulation was carried out for entire tunnel region. Detailed 3D CFD simulation was performed for the rescue station area in the central region of the tunnel by using the result of the 1D simulation as the boundary condition of the 3D simulation. Various type of cross passage installation were evaluated for the prevention of smoke diffusion to suggest the optimized interval of the cross passages in the rescue tunnel.
Keywords
Tunnel fire; Ventilation; Smoke control; Flow analysis; Computational fluid dynamics(CFD);
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Korea Institute of Construction and Transportation Technonlgy Evaluation and Planning, 2009, Internal report, pp. 30-31.
2 Meacham, B. J., 1998, Evolution of performancebased codes and fire safety design method, NIST, GCR 98-761, p. 65.
3 Chow, W. K. and Li, S. M., 1999, Safety requirement and regulations reviews on ventilation and fire for tunnels in the Hong Kong special administrative region, Tunnelling and Underground Space Technology, Vol. 14, pp. 18-20.
4 NFPA 130, 2000, Standard for fixed guide way transit and passenger rail systems, National Fire Pretection Association, USA.
5 Yang, S., Hur, N., Ryou, H. S., Kim, D. H. and Jang, Y. J., 2008, Numerical simulation of smoke ventilation in rescue route and cross passage of railroad tunnel(in Korean), Korean Journal of Air-conditioning and Refrigeration Engineering, Vol. 20, No. 1, pp. 1-10.   과학기술학회마을
6 Portmann, D. and Shaha, J., 2002, Optimal use of jet fans in the Gotthard base tunnel near the portals to support the emergency ventilation, International Tunnel Forum.
7 Alan, P. and Alexander, D., 2006, Movement of smoke in tunnels:A comparison of theory and practice, Computational Wind Engineering, pp. 585-588.
8 Kang, S. Y., Kim, K. H., Cho, Y. J., Lee, J. H. and Oh, M. D., 2000, Evaluation environment in a railroad tunnel on fire(in Korean), Proceedings of the SAREC 2000 Winter Annual Conference, pp. 181-187.
9 Kim, D. H. and Park, W. H., 2006, Experiment by reduced scale models for the fire safety of a rescue station in very long rail tunnel in Korea, Tunnelling and Underground Space Technology, Vol. 21, pp. 303-313.   DOI   ScienceOn