• 제목/요약/키워드: Refrigerant oil

검색결과 115건 처리시간 0.027초

접촉압력을 고려한 R-134a용 냉도기유의 윤활성 평가 연구

  • 나병철;전경진;한동철
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1997년도 제26회 추계학술대회
    • /
    • pp.145-151
    • /
    • 1997
  • PAG(Polyalkylene Glycol) and esters are tested with HFC-134a as a refrigeration oil. This investigation enhances the testing method by taking the compressor's environment into account. A testing environment charged with refrigerant gas more closely simulates the conditions of a compressor. The friction coetTicient of the PAG/HFC-134a system is similar to that of the mineral oil/CFC-12 system at operating conditions. Ester oils are preferable at the start & stop condition in the lubricity aspect. PAG shows good lubricity in conditions of extreme contact pressure. Consequently, this test provides reliable results on compressor lubricity of refrigeration oils with HFC-134a. It suggests a methodological way for the proper selection of refrigeration oils that may improve the durability and performance of a compressor.

  • PDF

압축기 습동부 윤활 특성 향상을 위한 나노유체 특성(열전도도, 분산성, 점도변화, 마찰거동) (Characteristics of Nano-Fluid Improvement of Lubrication for Compressor Friction Parts)

  • 김재욱;박철민;박중학;박상하
    • 한국기계가공학회지
    • /
    • 제16권2호
    • /
    • pp.108-113
    • /
    • 2017
  • The performance of refrigerant oil at the thrust bearing and at the journal bearing of a scroll compressor is a significant factor. This paper presents the friction and anti-wear characteristics of nano-fluid with a mixture of a refrigerant oil and nano powders. The particle size distribution and oxidation stability of nano powders prepared by the electrical explosion method were analyzed by TEM and BET. It was found that the nanoparticles showed a spherical morphology with sizes ranging of 40-60 nm and were covered with graphite layers of 2-4 nm. The thermal conductivity of POE oil was 0.1-0.5W/mk higher than that of POE oil. The coefficient of friction of Cu-POE was found to be 0.1 higher than that of Al2O3. The cooling capacity of the heat pump with nanofluid increased to 3.67%, and the performance was improved by 5.83%.

마이크로 휜 증발관내 냉매 R-290의 열전달 특성에 미치는 냉동유의 영향 (Influence of Refrigeration Oil on Evaporation Heat Transfer Characteristics of R-290 Inside Micro Fin Tube)

  • 박철민;안영태;이욱현;김정훈;김종수
    • 대한기계학회논문집B
    • /
    • 제24권7호
    • /
    • pp.938-944
    • /
    • 2000
  • Recently, micro fin tube is widely used to heat exchanger for high performance. And, as the alternative refrigerants for R-22, hydrocarbons such as R-290, R-600 and R-600a are very promising because of their low GWP and ODP. Thus, R-290 was used as working fluid in this study. Most design of heat exchanger had been based on heat transfer characteristics of pure refrigerant although refrigerant oil exists in the refrigeration cycles. So, the influence of oil on heat transfer characteristics have to be considered for investigating exact evaporation heat transfer characteristics. But, this is an unresolved problem of refrigeration heat transfer. Therefore the influence of the refrigeration oil to the evaporation heat transfer characteristics of R-290 were conducted in a horizontal micro tin tube. The mineral oil was used as refrigeration oil. The experimental apparatus consisted of a basic refrigeration cycle and a system for oil concentration measurement. Test conditions are as the follows; evaporation temperature $5^{\circ}C$, mass velocity 100 $kg/m^2s$, heat flux 10 $kW/m^2$, oil concentration 0, 1.3, 3.3, 5.7 wt.%, and quality $0.07{\sim}1.0$. When refrigeration oil was entered, oil foaming was observed at the low quality region. And, very small bubbles were observed as quality was increased. Pressure drop and heat transfer coefficient increased as the concentration of refrigeration oil increased to 5 wt.%.. The performance index of heat exchanger was the highest near 3.3 wt.%.

다공도가 다른 전열촉진관의 냉매 풀비등에 미치는 오일의 영향 (Effect of Oil on Pool Boiling of Refrigerant on Enhanced Tubes having Different Pore Sizes)

  • 김내현;이응렬;민창근
    • 설비공학논문집
    • /
    • 제18권3호
    • /
    • pp.254-261
    • /
    • 2006
  • The effect of enhanced geometry (pore diameter, gap width) is investigated on the pool boiling of R-123/oil mixture for the enhanced tubes having pores with connecting gaps. Tubes with different pore diameters (and corresponding gap widths) are specially made. Significant heat transfer degradation by oil is observed for the present enhanced tubes. At 5% oil concentration, the degradation is 26 to 49% for $T_{sat}=4.4^{\circ}C$. The degradation increases 50 to 67% for $T_{sat}=26.7^{\circ}C$. The heat transfer degradation is significant even with small amount of oil (20 to 38% degradation at 1% oil concentration for $T_{sat}=4.4^{\circ}C$), probably due to the accumulation of oil in sub-tunnels. The pore size (or gap width) has a significant effect on the heat transfer degradation. The maximum degradation is observed for $d_p$ = 0.20 mm tube at $T_{sat}=4.4^{\circ}C$, and for $d_p$=0.23 mm tube at $T_{sat}=26.7^{\circ}C$. The minimum degradation is observed for $d_p$=0.27 mm tube for both saturation temperatures. It appears that the oil removal is facilitated for the larger pore diameter (along with larger gap) tube. The highest heat transfer coefficient with oil is obtained for $d_p$ =0.23 mm tube, which yielded the highest heat transfer coefficient for pure R-123. The heat transfer degradation increases as the heat flux decreases.

셀 앤 플레이트 열 교환기에서의 R-410A 증발열전달에 관한 실험적 연구 (Experimental Study on R-410A Evaporation Heat Transfer Characteristics in Shell and Plate Heat Exchanger)

  • 김인관;김영수;박재홍
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권1호
    • /
    • pp.49-59
    • /
    • 2005
  • The evaporation heat transfer experiments are conducted with the shell and plate heat exchanger (S&PHE) without oil in the refrigerant loop using R-410A. An experimental refrigerant loop has been established to measure the evaporation heat transfer coefficient h. of R-410A in a vertical S&PHE. Two vertical counter flow channels were formed in the S&PHE by three plates haying a corrugated trapezoid shape of a $45^{\circ}C$ chevron angle. UP flow of the boiling R-410A in one channel receives heat from the hot down flow of water in the other channel The effects of the refrigerant mass flux. average heat flux. refrigerant saturation temperature and vapor qualify are explored in detail. Similar to the case of a plate heat exchanger. even at a very low Reynolds number, the flow in the S&PHE remains turbulent. The Present data shows that the evaporation heat transfer coefficients of R-410A increased with the vapor qualify. The results indicate a rise in the refrigerant mass flux caused an increase in the h.. Raising the imposed wall heat flux is found to slightly improve h., while h, is found to be lower at a higher refrigerant saturation temperature. Based on the present data. empirical correlation of the evaporation heat transfer coefficient is proposed.

헬리컬 코일관 내 초임계 $CO_2$의 압력강하 특성 (Pressure Drop Characteristics of Supercritical $CO_2$ in a Helically Coiled Tube)

  • 유태근;김대희;노건상;구학근;오후규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.216-221
    • /
    • 2005
  • The heat transfer coefficient and pressure drop during gas cooling process of carbon dioxide in a helically coiled tube were investigated experimentally. The experiments were conducted without oil in the refrigerant loop. The main components of the refrigerant loop are a receiver, a variable speed pump, a mass flowmeter, a pre-heater, a gas cooler(test section) and an isothermal tank. The test section is a double pipe type heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. It was made of a copper tube with the inner diameter of 4.85 [mm], the outer diameter of 6.35 [mm] and length of 10000 [mm]. The refrigerant mass fluxes were 200${\sim}$600 [kg/$m^2$s] and the average pressure varied from 7.5 [MPa] to 10.0 [MPa]. The main results were summarized as follows: The heat transfer coefficient of supercritical $CO_2$ increases, as the cooling pressure of gas cooler decreases. And the heat transfer coefficient increases with the increase of the refrigerant mass flux. The pressure drop decreases in increase of the gas cooler pressure and increases with increase the refrigerant mass flux.

  • PDF

운전조건 변화에 따른 R-22 냉동사이클과 R-410A 냉동사이클의 성능변화 비교 (Comparison of Performance Variation between R-22 and R-410A Refrigeration Systems)

  • 박태준;이민규;정지환;장근선
    • 설비공학논문집
    • /
    • 제15권3호
    • /
    • pp.166-176
    • /
    • 2003
  • Experiments have been conducted in order to make comparisons of a alternative refrigerant (R-410A) cycle characteristic with an existing refrigerant (R-22) cycle characteristic in terms of cooling capacity and coefficient of performance (COP). The parameters examined in the present work include air flow rate, indoor/outdoor air temperatures, and indoor relative humidity. These two refrigeration cycles share all components except compressor, accumulator, oil separator, and piping connecting them. The measurements were made using an air-enthalpy calorimeter. The experimental results show that the R-410A cycle has many advantages over indoor conditions while the R-22 cycle has better performance over outdoor conditions.

전산유체역학을 이용한 화장품 오일 캡슐레이션 현상에 대한 연구 (A Study on the Encapsulation of Cosmetic Oil Using Computational Fluid Dynamics)

  • 정남균
    • 한국산학기술학회논문지
    • /
    • 제22권2호
    • /
    • pp.638-643
    • /
    • 2021
  • 농업분야를 비롯한 식품산업 등 다양한 산업에서 사용되고 있는 오일은 기능성 화장품 개발에도 주요한 원료로 사용되고 있다. 오일은 산소나 빛, 습기 또는 고온에 노출되면 화학적으로 불안정하고 산화되기가 쉬운 특징이 있어 이러한 환경에 그대로 노출되지 않도록 캡슐화하기 위한 다양한 시도가 이루어지고 있다. 오일보다 밀도가 큰 냉매 안에 오일을 주입하면, 오일과 냉매의 밀도차로 인한 부력에 의해 오일이 떠오르면서 오일을 캡슐화 할 수 있는데, 본 연구에서는 이러한 방식의 오일 캡슐레이션 장비를 개발함에 있어 오일 캡슐화의 최적의 장비 구동조건을 찾기 위하여 다상유동에 대한 전산해석을 이용하여 오일 캡슐레이션 현상을 모사하였다. 냉매로는 물이나 세럼(Serum)을 이용할 수 있는 데, 상대적으로 점도가 상당히 작은 물을 냉매로 사용했을 경우는 오일과 물을 지속적으로 주입시키는 방식으로 장비를 구동하더라도 오일액적이 잘 생성됨을 알 수 있었으나, 점도가 매우 큰 세럼을 냉매로 사용했을 경우는 오일이 액적의 형태로 노즐에서 이탈되지 않고 길게 늘어지는 양상을 나타냈다. 세럼을 냉매로 이용한 경우는 오일을 연속으로 주입시키는 방법 대신 짧은 순간 빠르게 주입한 후 얼마의 시간동안 주입을 멈춰 부력에 의해 오일액적을 노즐로부터 이탈시키는 방법을 이용하면 오일액적 생성이 가능함을 알 수 있었다.

대체냉매 R436B를 적용한 정수기 냉각수 시스템 신뢰성 평가에 관한 연구 (A Study on the Reliability of Cooling Water Systems Using R436B)

  • 남현규;배상은;배철호;고정수;진병주;오주철
    • 설비공학논문집
    • /
    • 제25권8호
    • /
    • pp.438-442
    • /
    • 2013
  • The alternative refrigerant R436B is applied, to assess the application feasibility for a commercial cooling water system. The characteristic stability was verified by Sealed glass tube test and Autoclave test. R436B is chemically stable with the compressor material. The Oil miscibility test shows the usual compressor oil mixed well with R436B. Through the life acceleration test, the cooling performance is maintained. Though slight changes in oil and capillary tube diameter were found, they were within the permitted range. R436B should be applied to commercial cooling water systems as a simple replacement for the usual refrigerant.

나노 윤활유를 이용한 스크롤 압축기 저널 베어링의 윤활특성 평가 (Performance Evaluation of Nano-Lubricants at Journal Bearing of Scroll Compressors)

  • 김경민;황유진;이광호;성치언;이재근;정원현;김성춘;진홍균
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.189-193
    • /
    • 2008
  • Performance of refrigerant oil at the thrust-bearing and at the journal-bearing of a scroll compressor is a significant factor. This paper presents the friction and anti-wear characteristics of nano oil with a mixture of a refrigerant oil and carbon nano particles in the journal bearing of scroll compressors. The characteristics of friction and anti-wear using nano-oil is evaluated using the disk on disk tester and the journal bearing tester for measuring friction surface temperature and the coefficient of friction at the journal bearing tester. In journal bearing test, the average friction coefficient of high concentration nano-oil was decreased down to 18% compared to raw oil under 4,500 N and 3,600 rpm. It is believed that nano particles can be coated on the wear surfaces and the interaction of nano particles between surfaces can be improved the lubrication in the friction surfaces. Worn surfaces of frictional specimen were measured with straightness. carbon nano oil enhances the characteristics of the anti-wear and friction at the joural bearing of scroll compressors.

  • PDF