• Title/Summary/Keyword: Reflective Measurement

Search Result 124, Processing Time 0.032 seconds

Measurement of the Wear Amount of WC-coated Excavator Spacer using the PTA Process to Improve Wear Resistance by Using Reflective Digital Holography (반사형 디지털 홀로그래피를 이용한 내마모성 향상을 위한 공법이 적용된 PTA 굴착기의 초경 코팅 스페이서의 마모량 측정)

  • Shin, Ju-Yeop;Lim, Hyeong-Jong;Lee, Hang-Seo;Kim, Han-Sub;Jung, Hyun-Chul;Kim, Kyeong-suk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.1
    • /
    • pp.19-28
    • /
    • 2020
  • The spacer, which is located between the bucket and the arm of an excavator, has a role in preventing damage to the excavator arm during excavation work. When the durability of the spacer is increased, the lifetime of the arm can be extended and the processing costs can be reduced. To increase the durability of the spacer, tungsten carbide (WC) coating was applied on the surface of a spacer using the plasma transferred arc (PTA) process. The confirm the durability, a wear test using a pin-on disk type of wear testing machine was done under the given conditions and the wear amount on the surface of a tested specimen was measured using reflective digital holography. The results were compared with that of ALPHA-STEP.

Out-of-Band Measurement of LED-based Solar Blind UV Filters

  • Cui, Muhan;Zhou, Yue;Chen, Xue;Yan, Feng;Zhang, Mingchao;Yang, Huaijiang
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.244-250
    • /
    • 2014
  • Due to the difficulty in measuring very low out-of-band cutoff depths of solar blind UV filters, we propose a cutoff depth adjustable measurement system (CDAM) to test deep cutoff filters with a large dynamic range. The CDAM utilizing the substitution method is elaborately composed of several parts, including narrow-band LED light sources, standard reflective neutral attenuators with known attenuation coefficients, and a photomultiplier (PMT). This paper also presents an attenuator combination method ensuring that the PMT works within its linear response range. In addition, numerical simulation testifies to the method, and experiment shows that the CDAM system can achieve an extension of dynamic range from 0-6 OD to 0-10 OD, which is sufficient for the measurement of out-of-band cutoff depths of solar blind UV filters. Above all, the CDAM system, being easily implemented, of wide dynamic range, and highly precise, could be widely used in the measurement of filter cutoff depth.

Development of a Wireless, Battery-free SAW-based Temperature and Humidity Sensor incorporating a Bidirectional Reflective Delay Line (양방향 반사 지연선을 이용한 무선, 무전원 SAW 기반 온, 습도 센서 개발)

  • Lim, Chun-Bae;Lee, Kee-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1515_1516
    • /
    • 2009
  • A 440MHz wireless and passive surface acoustic wave (SAW) based micro-sensor was developed for simultaneous measurement of temperature and humidity. The developed sensor is composed of a SAW reflective delay lines structured by an IDT (Inter-Digital Transducer), four reflectors and humidity sensitive film (polyimide). Polyimide was dry-ecthed by RIE (Reactive Ion Etching) to obtain high roughness, which gives the large reaction area resulting in high sensitivity. In wireless testing using a network analyzer, sharp reflection peaks with high S/N ratio, small signal attenuation, and few spurious peaks were observed in the time domain. High sensitivity towards the temperature and humidiy were also observed in the large concentration range. The obtained sensitivity was $16.8^{\circ}/^{\circ}C$ for temperature sensor and $15.8^{\circ}$/%RH for humidity sensor.

  • PDF

Development of Diagnosis System through Human-body Information Measurement (생체정보측정을 통한 진단시스템 개발)

  • Shin, Jin-Seob;Ahn, Woo-Young;Oh, Il-Yong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.1
    • /
    • pp.219-226
    • /
    • 2008
  • The signal data from human body is very various and much. Because the signals can not occur equally to everyone, so when they analyze their signals, these signals can be used to diagnosis each health sign. In this system, human fingertips are connected with the five vital organs and the six viscera, and if we use these oriental medical diagnosis we can measure the pulse. temperature, and resistant from by reflective photosensor and interpret it's true and false.

  • PDF

Cell gap measurement method far single-polarizer reflective liquid crystal cells (분광기를 이용한 반사형 TN LCD의 셀갭 측정)

  • 이기동;박경호;이서헌;윤태훈;김재창
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.6
    • /
    • pp.468-471
    • /
    • 2001
  • A novel method to measure the cell gap of a single-polarizer reflective twisted nematic liquid crystal (TN LC) cell by using a rotating polarizer technique is proposed. By rotating an LC cell, we can measure the cell gap of an LC cell as well as the wavelength dependence of retardation under the condition that the twist angle is known.

  • PDF

Correlation between Dielectric Constant and Electronic Polarization by the Reflective Index (굴절률에 의한 유전상수와 전자에 의한 분극에 대한 상관성)

  • Oh, Teresa
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.1
    • /
    • pp.24-29
    • /
    • 2009
  • The SiOC film as inter layer insulator was researched the reason of the decreasing the dielectric constant by the ionic polarization and electronic polarization, respectively. The dielectric constant was measured using the conventional C-V measurement system, and the reflective index owing to the electronic polarization. Two kinds of dielectric constants were compared and then induced the origin of low-k materials. The chemical properties of the SiOC film were analyzed by the FTIR spectra, and the carbon content was obtained by the deconvoluted data of FTIR spectra. The variation of the carbon content tended to similar to the trend of reflective index, but was in inverse proportion to the dielectric constant. The effect of the electronic polarization did not affect the decreasing the dielectric constant, however the ionic polarization decreased effectively the dielectric constant of the SiOC film.

A Study on the Effects of Ambient Light on the Reflective PPG Measurement Device using Infrared (적외선을 사용한 반사형 PPG 측정 장치에서의 주변광의 영향에 대한 연구)

  • Namsub Kim
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.6
    • /
    • pp.406-412
    • /
    • 2023
  • In this paper, we studied the effect of noise caused by ambient light on a reflective PPG measurement device using infrared light. Noise caused by ambient light was examined by dividing it into general situations and special situations. In the general situation, noise due to changes in time and ambient light sources was randomly observed, and in the special situation, a halogen lamp was used to observe the effect of noise variations. In the experiment, PPG signals were measured and data acquired in real-time depending on each situation, and the measured data was analyzed in the time domain and frequency domain. First, through a general situation experiments, it was visually observed that noise increases with the brightness of ambient light, and through frequency analysis, it was observed that the noise sources were white noise, power line noise, and internal noise of the circuit. Futhermore, using a halogen lamp, we experimented with the change in noise depending on the change in distance from the ambient light and calculated the SNR. As a result of the experiment, an SNR of 3.2 dB was shown at a distance of 50 cm with an irradiance of 278.3 W/m2. It was observed that normal measurement was difficult at SNRs below that, and an irradiance of 27.7 W/m2 was obtained. It showed a value of 18.2 dB at a distance of 2 m, and it was observed that normal PPG measurement was possible through a filter at values above that.

Precision Displacement Measurement of Three-DOF Micro Motions Using Position Sensitive Detector and Spherical Reflector (PSD와 구면반사를 이용한 3자유도 미소 변위의 정밀측정)

  • 이재욱;조남규
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.7
    • /
    • pp.99-104
    • /
    • 2003
  • A precision displacement measurement system of 3-DOF micro motions is proposed in this paper. The measurement system is composed of two diode lasers, two quadratic PSDs, two beam splitters and a sphere whose surface is highly reflective. In this measurement system, the sphere reflector is mounted on the platform of positioning devices whose 3-DOF translational motions are to be measured, and the sensitive areas of two PSDs are oriented toward the center point of the sphere reflector. Each laser beam emitted from two diode laser sources is reflected at the surface of sphere and arrives at two PSDs. Each PSD serves as a 2-dimensional sensor, providing the information on the 3-dimensional position of the sphere. In this paper, we model the relationship between the outputs of two PSDs and 3-DOF translational motions of the sphere mounted on the object. Based on a deduced measurement model, we perform measurement simulation and evaluate the performance of the proposed measurement system: linearity, sensitivity, and measurement error. The simulation results show that the proposed measurement system can be valid means of precision displacement measurement of 3-dimensional micro motions.

Development of a Sensor System for Real-Time Posture Measurement of Mobile Robots (이동 로봇의 실시간 자세 추정을 위한 센서 시스템의 개발)

  • 이상룡;권승만
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.9
    • /
    • pp.2191-2204
    • /
    • 1993
  • A sensor system has been developed to measure the posture(position and orientation) of mobile robots working in industrial environments. The proposed sensor system consists of a CCD camera, retro-reflective landmarks, a strobe unit and an image processing board. The proposed hardware system can be built in economic price compared to commercial vision systems. The system has the capability of measuring the posture of mobile robots within 60 msec when a 386 personal computer is used as the host computer. The experimental results demonstrated a remarkable performance of the proposed sensor system in the posture measurement of mobile robots - the average error in position is less than 3 mm and the average error in orientation is less than 1.5.

Accuracy Evaluation of Reflective Sheet Target Total Station for Applying in Cadastral Resurvey (지적재조사 측량에 적용을 위한 반사시트 타깃 토털스테이션 측량의 정확도 평가)

  • Park, Ki Heon;Hong, Sung Eon
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.4
    • /
    • pp.91-97
    • /
    • 2014
  • In this research, we would try to evaluate the applicability in cadastral resurvey surveying by analysing the accuracy of building boundary surveying using the reflective sheet total station surveying. When we analyse it, we refer the reflective sheet which can supplement not only the difficulties of total station surveying and GPS surveying caused by the diversity of the building structure but also the errors of non prism total station caused by material of the object. Each reflected angles $90^{\circ}$ and $60^{\circ}$, $30^{\circ}$ of RMSE results were analyzed by RMSE between 1.2mm~2.8mm and 2.2mm~4.0mm, 2.5mm~4.4mm for each distance. The result of X RMSE was analyzed to be 0.0043m in a boundary surveying for existing building between prism surveying and reflective sheet surveying, and also Y RMSE was 0.038m. The source of error is estimated that the body of the prism can not be exactly attached to the edge of a building. Therefore, it will be very helpful to use a reflective sheet surveying with a prism in both the limit of collimation and error reductions as a building boundary measurement in cadastral resurvey surveying.