• Title/Summary/Keyword: Reflection Mode

Search Result 242, Processing Time 0.028 seconds

An analysis of characteristics of corrugated horn antenna using surface impedance condition (표면 경계조건을 이용한 코러게이트 혼 안테나 특성 해석)

  • ;;Alexander Shishlov
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.6
    • /
    • pp.1587-1595
    • /
    • 1996
  • We obtained the predicted and measured results for the reflection coefficient and radiation pattern of Ka-band (20- GHz) corrugated horn, which is usually used for feeder of reflector antenna for satellite communication, using suface impedance condition. In order to predict the reture losses of corrugated horn, we analyzed propagation constant of hybrid mode in the corrugated waveguide and then obtained the total reflection coefficient using the circuti theory of multi-step transformer. We also got the radiation pattern of corrugated horn with small flare angle, considering the phase deviation and integrate transverse field on aperture. A test model of corrugated horn antenna for Ka-band designed using theory and program displayed performance and the results agree with the theoretical prediction.

  • PDF

Reflection-type Optical Waveguide Index Profiling Technique

  • Youk YoungChun;Kim Dug Young
    • Journal of the Optical Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.49-53
    • /
    • 2005
  • We report a new configuration of a reflection-type confocal scanning optical microscope system for measuring the refractive index profile of an optical waveguide. Several improvements on the earlier design are proposed; a light emitting diode (LED) at 650 nm wavelength instead of a laser diode (LD) or He-Ne laser is used as a light source for better index precision, and a simple longitudinal linear scanning and curve fitting techniques are adapted instead of a servo control for maintaining an optical confocal arrangement. We have obtained spatial resolution of 700 nm and an index precision of $2\times10^{-4}$. To verify the system's capability, the refractive index profiles of a conventional multimode fiber and a home-made four-mode fiber were examined with our proposed measurement method.

Optimal Shape Design of Waveguide Matched Load Using 3 Dimensional Vector Finite Element Method (3차원 벡터유한요소법을 이용한 도파관 정합부하의 최적형상설계)

  • Kim, Jun-O;Lee, Hong-Bae;Cheon, Chang-Yul;Hahn, Song-Yop;Kim, Hyeong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1213-1215
    • /
    • 1994
  • The shape of lossy material inside a waveguide matched load is optimally designed to give low reflection over a given frequency range. The 3 dimensional vector finite element mettled is used as an analysis tool which does not generate spurious mode. The optimizing process used in this parer is the Powell technique. The designed load gives the low reflection about -30 dB around 10GHz with 1.5 wavelength of the load length.

  • PDF

Design of a Dual-Mode Planar Antenna Using a Reconfigurable Matching Network (재구성 정합 회로를 이용한 평판형 이중 모드 안테나 설계)

  • Kim, Yoon Geon;Kay, Youngchul;Choo, Hosung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.12
    • /
    • pp.1337-1342
    • /
    • 2012
  • In this paper, we propose a novel reconfigurable antenna that can change the electrical shape of the matching network using RF switches of PIN diodes. The designed antenna operates at two different modes that are Mode 1 (HSDPA band, 2.1~2.2 GHz) and Mode 2(WiBro WiFi band, 2.3~2.5 GHz). The antenna is built on both sides of a polyarcylate substrate. The measured reflection coefficient shows a matching bandwidth of 547 MHz($S_{11}$ <-3 dB, 2.035~2.582 GHz) for Mode 1 and 600 MHz($S_{11}$ <-3 dB, 2.2~2.8 GHz) for Mode 2, and it shows average vertical gains of -4.4 dBi and -4.5 dBi in x-y plane, respectively.

Simulation and Examination for Beam Profile of DFB Laser with an Anti-reflection Coated Mirror (무반사 면을 갖는 DFB 레이저의 빔 분포 시뮬레이션과 검정)

  • Kwon, Kee-Young;Ki, Jang-Geun
    • Journal of Software Assessment and Valuation
    • /
    • v.16 no.1
    • /
    • pp.55-63
    • /
    • 2020
  • Lasers for optical broadband communication systems should have excellent frequency selectivity and modal stability. DFB lasers have low lasing frequency shift during high speed current modulation. In this paper, when a refractive index grating and a gain grating are simultaneously present in a DFB laser having a wavelength of 1.55 ㎛, the dielectric film is coated so that reflection does not occur on the right mirror surface, so that ρr=0. For the first mode, which requires a minimum gain at the threshold, the beam distribution of the oscillation mode in the longitudinal direction and the radiated power ratio Pl/Pr were analyzed and compared for the cases of the phase of ρl=π and π/2. If the phase of ρl=π, in order to obtain a low threshold current and high frequency stability, κL should be greater than 8. In the case of the phase of ρl=π/2, for low threshold current, κL is necessary to be 1.0, where the oscillation frequency coincides with the lattice frequency. DFB lasers with an anti-reflection coated mirror have excellent mode selectivity than 1.55um DFB lasers with two mirror facets

A Compact Tunable VCSEL and a Built-in Wavelength Meter for a Portable Optical Resonant Reflection Biosensor Reader

  • Ko, Hyun-Sung;Kim, Bong-Kyu;Kim, Kyung-Hyun;Huh, Chul;Kim, Wan-Joong;Hong, Jong-Cheol;Park, Seon-Hee;Yang, Seong-Seok;Jang, Ho-Jin;Sung, Gun-Yong
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.395-402
    • /
    • 2010
  • This study reports a portable and precision photonic biosensor reader that can measure the concentration of a particular antigen using an optical resonant reflection biosensor (ORRB). To create a compact biosensor reader, a compact tunable vertical-cavity surface-emitting laser (VCSEL) and a compact built-in wavelength meter were manufactured. The wavelength stability and accuracy of the compact built-in wavelength meter were measured to be less than 0.02 nm and 0.06 nm, respectively. The tunable VCSEL emission wavelength was measured with the compact built-in wavelength meter, it has a fast sweep time (~ 10 seconds) and a wide tuning range (> 4 nm) that are sufficient for biosensor applications based on ORRB. The reflection spectrum of a plastic based ORRB chip was measured by the fabricated portable photonic biosensor reader using the VCSEL and wavelength meter. Although the reader is the size of a palmtop device, it could make a precise measurement of the peak wavelength on equal terms with a conventional bulky optical spectrometer.

Implementation of new gestures on the Multi-touch table

  • Park, Sang Bong;Kim, Beom jin
    • International Journal of Advanced Culture Technology
    • /
    • v.1 no.1
    • /
    • pp.15-18
    • /
    • 2013
  • This paper describes new gestures on the Multi-touch table. The 2 new gestures with 3 fingers are used for minimizing of all windows that is already open and converting Aero mode. We also implement a FTIR (Frustrated Total Internal Reflection) Multi-touch table that consists of sheet of acrylic, infrared LEDs, camera and rear projector. The operation of proposed gestures is verified on the implemented Multi-touch table.

  • PDF

Dynamics of an atomic wave packet in a standing wave quantized field

  • Tak, Jo-Yeong;Won, An-Gyeong
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.252-253
    • /
    • 2001
  • The purpose of this work is to investigate the dynamics of an atomic wave packet whose center-of-mass motion is quantized in a resonant standing wave cavity field. The mechanical aspect of the matter-field interaction has been extensively studied In the theme of atomic beam deflection, diffraction, or reflection by a standing-wave field. The effect caused in the behavior of spontaneous emission by the atomic center-of-mass motion, classical and quantized, in a standing wave cavity mode has been studied, and recently the one-atom laser with quantized atomic center-of-mass motion has been investigated. (omitted)

  • PDF

Stability Properties of Semiconductor Lasers with Optical Feedback from an External Grating

  • Park, Jong-Dae;Cho, Chang-Ho;Kim, Chil-Min
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.153-157
    • /
    • 1991
  • We report an analysis on the stability properties of external cavity semiconductor lasers exposed to strong feedback from an external grating. The frequency range of stable single mode oscillation is found to depend on the offset between the resonance frequency of the solitary laser and the frequency of maximum reflection from the grating.

  • PDF

A Study on Narrow-Band Dual-Mode Channel Filter and Equalizer for Ku band Satellite Transponder (Ku 대역 위성 중계기용 이중모드 협대역 채널 여파기 및 등화기에 관한 연구)

  • 이주섭;엄만석;강승택;박상준;염인복;이성팔
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.4B
    • /
    • pp.372-378
    • /
    • 2002
  • In this paper, a narrow-band waveguide channel fitter has been designed and realized for Ku band satellite transponder. Group-delay and amplitude variations of the channel filter have been minimized using a 2-pole reflection type equalizer. The channel filter has been designed to have the 8-pole elliptic response for high frequency selectivity. Dual-mode technique has been adopted for reducing mass and volume of the channel filter and equalizer. The channel filter and equalizer have shown good performance for satellite transponder.