• Title/Summary/Keyword: Reference state approach

Search Result 108, Processing Time 0.025 seconds

Internet Traffic Control Using Dynamic Neural Networks

  • Cho, Hyun-Cheol;Fadali, M. Sami;Lee, Kwon-Soon
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.285-291
    • /
    • 2008
  • Active Queue Management(AQM) has been widely used for congestion avoidance in Transmission Control Protocol(TCP) networks. Although numerous AQM schemes have been proposed to regulate a queue size close to a reference level, most of them are incapable of adequately adapting to TCP network dynamics due to TCP's non-linearity and time-varying stochastic properties. To alleviate these problems, we introduce an AQM technique based on a dynamic neural network using the Back-Propagation(BP) algorithm. The dynamic neural network is designed to perform as a robust adaptive feedback controller for TCP dynamics after an adequate training period. We evaluate the performances of the proposed neural network AQM approach using simulation experiments. The proposed approach yields superior performance with faster transient time, larger throughput, and higher link utilization compared to two existing schemes: Random Early Detection(RED) and Proportional-Integral(PI)-based AQM. The neural AQM outperformed PI control and RED, especially in transient state and TCP dynamics variation.

New Design Approach for the Uniform Temperature of Precision Hot Plates (초정밀 가열판의 온도 균질화를 위한 새로운 설계방법)

  • Park, Yong-Qwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.11
    • /
    • pp.1525-1533
    • /
    • 2003
  • In the precision hot plate for wafer processing, uniform temperature of the upper plate is one of key factors affecting the quality of wafers. The state-of-the-art precision hot plates require temperature Variations less than $\pm$0.4$^{\circ}C$ during heating to 15$0^{\circ}C$, Which is difficult to be obtained only by the improvement of manufacturing techniques alone. In this study, computer aided heat transfer analysis was carried out to obtain the temperature distribution of the currently used reference hot plate for 200mm wafer. The analysis on the reference model assuming constant heat generation rate and uniform heating area showed total variation of 0.926$^{\circ}C$ at 15$0^{\circ}C$. One of the new design approaches based on the change of heating location together with different heat generation rate resulted in total variation of 0.297$^{\circ}C$ which is a 68% improvement compared to that of the reference model.

A Wideband Clock Generator Design using Improved Automatic Frequency Calibration Circuit (개선된 자동 주파수 보정회로를 이용한 광대역 클록 발생기 설계)

  • Jeong, Sang-Hun;Yoo, Nam-Hee;Cho, Seong-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.2
    • /
    • pp.451-454
    • /
    • 2011
  • In this paper, a wideband clock generator using novel Automatic frequency calibration(AFC) scheme is proposed. Wideband clock generator using AFC has the advantage of small VCO gain and wide frequency band. The conventional AFC compares whether the feedback frequency is faster or slower then the reference frequency. However, the proposed AFC can detect frequency difference between reference frequency with feedback frequency. So it can be reduced an operation time than conventional methods AFC. Conventional AFC goes to the initial code if the frequency step changed. This AFC, on the other hand, can a prior state code so it can approach a fast operation. In simulation results, the proposed clock generator is designed for DisplayPort using the CMOS ring-VCO. The VCO tuning range is 350MHz, and a VCO frequency is 270MHz. The lock time of clock generator is less then 3us at input reference frequency, 67.5MHz. The phase noise is -109dBC/Hz at 1MHz offset from the center frequency. and power consumption is 10.1mW at 1.8V supply and layout area is $0.384mm^2$.

Design of robust stable hybrid controllers for active noise/vibration control (능동 소음 및 진동 제어에 사용되는 강인안정한 하이브리드 제어기의 설계)

  • Oh, Shi-Hwan;Park, Young-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.431-436
    • /
    • 2000
  • Adaptive feed forward control algorithms based largely upon LMS approach have developed in recent two decades, and they have been widely applied to practical sound and vibration control problems in the case of the reference signal is available. Feedforward control can be applied only when reference signals can be measured or regenerated, while feedback controllers are used to reduce; sound and vibration when reference signals are not available. In recent years, hybrid control schemes in which adaptive feed forward controllers are combined with feedback ones have been studied based on simulations and experiments. The results have shown that the hybrid control may have better control performances in convergence speed and steady state error than the single control schemes. Hybrid control has the advantages of improving stability and performance as well as the disturbance rejection property. However, little effort has been made to the analysis or interpretation of hybrid control systems. In this study, we discussed the feedback controller effects on the stability of feed forward control algorithm in the presence of uncertain error path and a simple example showed that a stable feedback controller could make the feedforward controller unstable. A design criterion of feedback controllers is proposed in order to guarantee the stability of feedforward algorithms in the presence of error paths with uncertainties.

  • PDF

SDRE Based Near Optimal Controller Design of Permanent Magnet Synchronous Generator for Variable-Speed Wind Turbine System (가변속 풍력 발전용 영구자석형 동기발전기의 SDRE 기반 준최적 비선형 제어기 설계)

  • Park, Hyung-Moo;Choi, Han Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.1
    • /
    • pp.28-33
    • /
    • 2015
  • In this paper, we propose a near optimal controller design method for permanent magnet synchronous generators (PMSGs) of MW-class direct-driven wind turbine systems based on SDRE (State Dependent Riccati Equation) approach. Using the solution matrix of an SDRE, we parameterize the optimal controller gain. We present a simple algorithm to compute the near optimal controller gain. The proposed optimal controller can enable PMSGs to precisely track the reference speed determined by the MPPT algorithm. Finally, numerical simulation results are given to verify the effectiveness of the proposed optimal controller.

Generalized State-Space Modeling of Three Phase Self-Excited Induction Generator For Dynamic Characteristics and Analysis

  • Kumar Garlapati Satish;Kishore Avinash
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.4
    • /
    • pp.482-489
    • /
    • 2006
  • This paper presents the generalized dynamic modeling of self-excited induction generator (SEIG) using state-space approach. The proposed dynamic model consists of induction generator; self-excitation capacitance and load model are expressed in stationary d-q reference frame with the actual saturation curve of the machine. An artificial neural network model is implemented to estimate the machine magnetizing inductance based on the knowledge of magnetizing current. The dynamic performance of SEIG is investigated under no load, with the load, perturbation of load, short circuit at stator terminals, and variation of prime mover speed, variation of capacitance value by considering the effect of main and cross-flux saturation. During voltage buildup the variation in magnetizing inductance is taken into consideration. The performance of SEIG system under various conditions as mentioned above is simulated using MATLAB/SIMULINK and the simulation results demonstrates the feasibility of the proposed system.

Current Control of Inverter-Fed Induction Motor Using Integral Variable Structure Control (적분형 가변구조 제어를 이용한 인버터 구동 유도전동기의 전류제어)

  • Chung, Se-Kyo;Lee, Jung-Hoon;Park, Jae-Woo;Youn, Myung-Joong
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.270-272
    • /
    • 1994
  • A new current control technique for inverter-fed vector controlled induction motor drives is presented. Using a integral variable structure control(IVSC) approach, the current controller is designed in the stationary rotating reference frame. The chattering reduction technique is also considered by the full state flux observer. By employing the proposed control scheme, a good control performance is achieved in the transient and steady state. The effectiveness of the proposed scheme is demonstrated through the comparative simulations.

  • PDF

A Novel Parameter-independent Fictive-axis Approach for the Voltage Oriented Control of Single-phase Inverters

  • Ramirez, Fernando Arturo;Arjona, Marco A.;Hernandez, Concepcion
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.533-541
    • /
    • 2017
  • This paper presents a novel Parameter-Independent Fictive-Axis (PIFA) approach for the Voltage-Oriented Control (VOC) algorithm used in grid-tied single-phase inverters. VOC is based on the transformation of the single-phase grid current into the synchronous reference frame. As a result, an orthogonal current signal is needed. Traditionally, this signal has been obtained from fixed time delays, digital filters or a Hilbert transformation. Nevertheless, these solutions present stability and transient drawbacks. Recently, the Fictive Axis Emulation (FAE) VOC has emerged as an alternative for the generation of the quadrature current signal. FAE requires detailed information of the grid current filter along with its transfer function for signal creation. When the transfer function is not accurate, the direct and quadrature current components present steady-state oscillations as the fictive two-phase system becomes unbalanced. Moreover, the digital implementation of the transfer function imposes an additional computing burden on the VOC. The PIFA VOC presented in this paper, takes advantage of the reference current to create the required orthogonal current, which effectively eliminates the need for the filter transfer function. Moreover, the fictive signal amplitude and phase do not change with a frequency drift, which results in an increased reliability. This yields a fast, linear and stable system that can be installed without fine tuning. To demonstrate the good performance of the PIFA VOC, simulation and experimental results are presented.

Nutritional intake of Korean population before and after adjusting for within-individual variations: 2001 Korean National Health and Nutrition Survey Data

  • Kim, Dong-Woo;Shim, Jae-Eun;Paik, Hee-Young;Song, Won-O;Joung, Hyo-Jee
    • Nutrition Research and Practice
    • /
    • v.5 no.3
    • /
    • pp.266-274
    • /
    • 2011
  • Accurate assessment of nutrient adequacy of a population should be based on usual intake distribution of that population. This study was conducted to adjust usual nutrient intake distributions of a single 24-hour recall in 2001 Korean National Health and Nutrition Surveys (KNHNS) in order to determine the magnitude of limitations inherent to a single 24-hour recall in assessing nutrient intakes of a population. Of 9,960 individuals who provided one 24-hour recall in 2001 KNHNS, 3,976 subjects provided an additional one-day 24-hour recall in 2002 Korean National Nutrition Survey by Season (KNNSS). To adjust for usual intake distribution, we estimated within-individual variations derived from 2001 KNHNS and 2002 KNNSS using the Iowa State University method. Nutritionally at risk population was assessed in reference to the Dietary Reference Intakes for Koreans (KDRIs). The Korean Estimated Average Requirement (Korean EAR) cut-point was applied to estimate the prevalence of inadequate nutrient intakes except for iron intakes, which were assessed using the probability approach. The estimated proportions below Korean EAR for calcium, riboflavin, and iron were 73%, 41%, and 24% from usual intake distribution and 70%, 51%, and 39% from one-day intake distribution, respectively. The estimated proportion of sodium intakes over the Intake Goal of 2,000 mg/day was 100% of the population after adjustment. The energy proportion from protein was within Korean Acceptable Macronutrient Distribution Ranges (Korean AMDR), whereas that of carbohydrate was higher than the upper limit and that of fat was below the lower limit in the subjects aged 30 years or older. According to these results, the prevalence of nutritional inadequacy and excess intake is over-estimated in Korea unless usual intake distributions are adjusted for one-day intakes of most nutrients.

Basic concepts, recent advances, and future perspectives in the diagnosis of bovine mastitis

  • Samah Attia Algharib;Ali Sobhy Dawood;Lingli Huang;Aizhen Guo;Gang Zhao;Kaixiang Zhou;Chao Li;Jinhuan Liu;Xin Gao;Wanhe Luo;Shuyu Xie
    • Journal of Veterinary Science
    • /
    • v.25 no.1
    • /
    • pp.18.1-18.27
    • /
    • 2024
  • Mastitis is one of the most widespread infectious diseases that adversely affects the profitability of the dairy industry worldwide. Accurate diagnosis and identification of pathogens early to cull infected animals and minimize the spread of infection in herds is critical for improving treatment effects and dairy farm welfare. The major pathogens causing mastitis and pathogenesis are assessed first. The most recent and advanced strategies for detecting mastitis, including genomics and proteomics approaches, are then evaluated. Finally, the advantages and disadvantages of each technique, potential research directions, and future perspectives are reported. This review provides a theoretical basis to help veterinarians select the most sensitive, specific, and cost-effective approach for detecting bovine mastitis early.