• 제목/요약/키워드: Reference signals

검색결과 613건 처리시간 0.029초

Pseudo-Correlation-Function Based Unambiguous Tracking Technique for CBOC (6,1,1/11) Signals

  • Jeong, Gil-Seop;Kong, Seung-Hyun
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제4권3호
    • /
    • pp.107-114
    • /
    • 2015
  • Binary Offset Carrier (BOC) signal planned for future Global Navigation Satellite System (GNSS) provided better positioning accuracy and smaller multipath error than GPS C/A signal. However, due to the multiple side peaks in the auto-correlation function (ACF) of the BOC modulated signals, a receiver may false lock onto one of the side peaks in the tracking mode. This false lock would then result in a fatal tracking error. In this paper, we propose an unambiguous tracking method for composite BOC (CBOC) signals to mitigate this problem. It aims to reduce the side peaks of the ACF of CBOC modulated signals. It is based on the combination of traditional CBOC correlation function (CF) and reference CF of unmodulated pseudo- random noise code (PRN code). First, we present that cross-correlation function (CCF) with unmodulated PRN code is close to the secondary peaks of the traditional CBOC. Then, we obtain an unambiguous correlation function by subtracting traditional CBOC ACF from these CFs. Finally, the tracking performance for the CBOC signals is examined, and it is shown that the proposed method has better performance than the traditional unambiguous tracking method in additive white Gaussian noise (AWGN) channel.

적응잡음제거기를 위한 정규 부호화 알고리즘의 수렴특성 분석 (A Convergence Analysis of Normalized Sign Algorithm for Adaptive Noise Canceler)

  • 김현태;박장식;배종갑;손경식
    • 한국통신학회논문지
    • /
    • 제24권6B호
    • /
    • pp.1203-1210
    • /
    • 1999
  • 적응필터에서는 기준 입력신호와 상관없는 원신호의 목표신호 성분에 의해서 적응필터의 계수가 오조정된다. 본 논문에서는 목표신호가 있는 경우에 대해서 NSA(normalized sign algorithm)의 정상상태 성능과 수렴특성을 NLMS 알고리즘과 비교 분석했다. NLMS 알고리즘의 평균자승오차는 목표신호의 전력에 비례하지만, NSA는 목표신호 전력의 제곱근에 비례한다. 수렴특성은 목표신호가 큰 경우 NSA는 NLMS 알고리즘에 비해서 느리게 적응한다. 본 논문에서는 이론적으로 분석된 정상상태 성능과 수렴특성을 컴퓨터 시뮬레이션을 통해서 검증한다.

  • PDF

전자파를 이용한 목표물의 특성 분석에 관한 연구 (A Study on Analysis of Target Characteristics Using Electromagnetic Waves)

  • 이종길
    • 한국정보통신학회논문지
    • /
    • 제19권6호
    • /
    • pp.1289-1295
    • /
    • 2015
  • 안테나에서 송출된 전자파 신호는 목표물로부터 반사되어져 수신된다. 이러한 반사 신호는 유전율 차이 등 목표물들의 물질 종류에 따라 서로 다른 특징들을 나타내게 된다. 따라서 이러한 반사 신호들의 특징들을 잘 활용하면 목표물들의 특성을 파악할 수 있다. 즉 위험 물질들의 분류 및 검사를 위하여 이러한 방법을 적용할 수 있다. 따라서 본 논문에서는 실험을 통하여 획득한 이러한 반사파 신호들의 특징을 활용하여 상관성(correlation)을 도출함으로서 그 특성, 즉 위험 물질들을 판단할 수 있는 방법을 고찰하고자 한다. 이러한 상관성에 의한 판단 방법은 특정 목표물에 대한 기준 신호의 저장을 필요로 하지만 비교적 신뢰할 수 있는 결과들을 보여준다. 그러므로 이러한 수신신호들의 상관성을 이용한 방법을 적용한다면 위험물질들의 구별 및 분류 등에 폭 넓게 활용할 수 있을 것이다.

40 채널 SQUID 미분계 시스템을 이용한 정상인과 WPW 증후군 및 확장성 심근증 환자의 심자도 비교 (Application of 40-channel SQUID Gradiometer System for the Comparison of Magnetocardiograms from Healthy Subjects and Patients with WPW syndrome and DCM)

  • 정용석;권혁찬;김기웅;이용호;강찬석;김진목;박용기;김기영;박기락
    • Progress in Superconductivity
    • /
    • 제5권1호
    • /
    • pp.38-44
    • /
    • 2003
  • The aim of this study is to confirm clinical usefulness of magnetocardiogram (MCG) by analyzing MCG data of health subjects and patients with Wolff-Parkinson-White (WPW) syndrome and dilated cardiomyopathy (DCM). Measurement of MCG signals was done with a home-made 40-channel SQUID system. MCG signals of 30 healthy subjects were measured as the reference of MCG signals. Among the DCM patients, 7 patients showed abnormal the direction of T wave vector. For a WPW syndrome patient, we measured the MCG signals before and after the surgery. and compared the difference. From the measured magnetic field distribution, current vector map was obtained to show the myocardium current activity. By comparing the MCG signals and current maps, we showed the differences in the analysis results between the healthy subjects and patients with heart diseases.

  • PDF

포켈스 소자를 이용한 고전압 임펄스 및 미소신호 측정기술 개발 (Development of Measuring Techniques for High Voltage Impulse and Small Signals using Pockels Cell)

  • 홍진영;이정헌;장용무;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1571-1573
    • /
    • 1994
  • In order to substitute for the conventional measuring system which could bring about technical inconveiences, measuring techniques for the fast transient high voltage upto 100 kV and small signals less than 1 V are developed by use of Laser Source with Packets cell. for the former, capacitive voltage divider was specially designed for reducing the impulse voltage less than the half-wave voltage of pockets cell. For the tatter, interferometer type was employed as a mean to removing the fluctuation of Laser output intensity. And also the main beam through the Pockels cell and the reference beam from the Laser source are seperated before being detected respectively by photo diodes. And then, these two signals are amplified and compared for detecting only the small signals applied across the Pockels cell. Throughout this work, Laser-based measuring system is likely to enable us, at this moment, to detect correctly lightning impulse voltage upto 100 kV and the small signals less than 1 V upto the 2 MHz. Such a system could be employed as a possible diagnostic measuring system at the substation.

  • PDF

비접촉형 심박수 측정 정확도 향상을 위한 인공지능 기반 CW 레이더 신호처리 (Artificial Intelligence-Based CW Radar Signal Processing Method for Improving Non-contact Heart Rate Measurement)

  • 윤원열;권남규
    • 대한임베디드공학회논문지
    • /
    • 제18권6호
    • /
    • pp.277-283
    • /
    • 2023
  • Vital signals provide essential information regarding the health status of individuals, thereby contributing to health management and medical research. Present monitoring methods, such as ECGs (Electrocardiograms) and smartwatches, demand proximity and fixed postures, which limit their applicability. To address this, Non-contact vital signal measurement methods, such as CW (Continuous-Wave) radar, have emerged as a solution. However, unwanted signal components and a stepwise processing approach lead to errors and limitations in heart rate detection. To overcome these issues, this study introduces an integrated neural network approach that combines noise removal, demodulation, and dominant-frequency detection into a unified process. The neural network employed for signal processing in this research adopts a MLP (Multi-Layer Perceptron) architecture, which analyzes the in-phase and quadrature signals collected within a specified time window, using two distinct input layers. The training of the neural network utilizes CW radar signals and reference heart rates obtained from the ECG. In the experimental evaluation, networks trained on different datasets were compared, and their performance was assessed based on loss and frequency accuracy. The proposed methodology exhibits substantial potential for achieving precise vital signals through non-contact measurements, effectively mitigating the limitations of existing methodologies.

A Direct Adaptive Fuzzy Control of Nonlinear Systems with Application to Robot Manipulator Tracking Control

  • Cho, Young-Wan;Seo, Ki-Sung;Lee, Hee-Jin
    • International Journal of Control, Automation, and Systems
    • /
    • 제5권6호
    • /
    • pp.630-642
    • /
    • 2007
  • In this paper, we propose a direct model reference adaptive fuzzy control (MRAFC) for MIMO nonlinear systems whose structure is represented by the Takagi-Sugeno fuzzy model. The adaptive law of the MRAFC estimates the approximation error of the fuzzy logic system so that it provides asymptotic tracking of the reference signal for the systems with uncertain or slowly time-varying parameters. The developed control law and adaptive law guarantee the boundedness of all signals in the closed-loop system. In addition, the plant state tracks the state of the reference model asymptotically with time for any bounded reference input signal. To verify the validity and effectiveness of the MRAFC scheme, the suggested analysis and design techniques are applied to the tracking control of robot manipulator and simulation studies are carried out. In the control design, the MRAFC is combined with feedforward PD control to make the actual joint trajectories of the robot manipulator with system uncertainties track the desired reference joint position trajectories asymptotically stably.

A Design and Measurement of a Reference Signal Generator for a Radar System

  • Kim, Dong-Sik;Kim, Min-Chul;Lee, Su-Ho;Baik, Seung-Hun;Kwon, Ho-Sang;Jeong, Myung-Deuk
    • Journal of electromagnetic engineering and science
    • /
    • 제9권3호
    • /
    • pp.118-123
    • /
    • 2009
  • This paper discusses the design and fabrication of a reference signal generator for a naval radar system, including the vibration environment test. The transmit signals of the S-band radar system are synthesized by the reference signal and the phase noise must lower than - 130 dBc/Hz at a 10 kHz offset frequency. To achieve this specification, the phase noise of the reference signal needs to be less than -165 dBc/Hz at a 10 kHz offset. For achieving very low phase noise performance by the reference signal generator, the phase locked loop technique is applied with a 10 Hz loop bandwidth. Also, this reference signal generator has ${\pm}0.35\;ppb$ short-term stability to minimize instant phase errors and high vibration sensitivity against a ship's shaking, unbalanced rotating of antennas and so on.

적외선 검출기를 위한 액체 질소 온도 동작 밴드갭 기준회로의 설계

  • 김연규
    • 항공우주기술
    • /
    • 제3권1호
    • /
    • pp.251-256
    • /
    • 2004
  • 적외선 소자로부터 생성되는 신호와의 비교에 의한 잡음 특성의 향상, 즉 좋은 영상을 얻기 위해서 적외선 영상신호 취득회로(ROIC)에서는 안정적인 기준 전압원이 필요하다. 본 논문은 극저온인 77K에서 동작하는 적외선 영상신호 취득회로(readout integrated circuit)를 위한 밴드갭 기준회로에 대해서 제안하고 있다. 기본에 발표된 대부분의 밴드갭 기준회로는 실온에서 동작하는 것이며, 액체질소 온도 77K에서 동작하는 적외선 영상 ROIC에는 적합하지 않다. 본 논문에서는 극저온에서 동작하는 밴드갭 기준회로 설계를 위하여, 온도변화에 따른 사용되는 소자들의 parameter에 대한 특성을 살펴본 후, 이러한 특성들을 고려하여 밴드갭 기준 회로를 제안하였으며 이것은 그 실용 가능성을 입증하고 있다.

  • PDF

Method of Measuring the Occupied Bandwidth of IS-95 Base Station at Remote Site

  • Lim, Jong-Soo;Kim, Sang-Tae
    • Journal of electromagnetic engineering and science
    • /
    • 제3권1호
    • /
    • pp.7-11
    • /
    • 2003
  • CDMA(code division multiple access) has very large peak to average power ratio(PAR) and behave as noise-like wide band digital signals with 1.2288 Mbps transmission rate. For signals with high PAR like CDMA, it is reasonable to prescribe occupied bandwidth(OBW) as average occupied bandwidth. Bandwidth measurements of CDMA signals at remote site are affected by co-channel and adjacent channel interference from adjacent CDMA base station, distortion of signal by fading effect, spurious emission and environment noises. In this study, we have compared OBW measurements in an on-air environment with those measured in a base station using adjacent channel leakage ratio(ACLR) as a reference measurement factor. As results of analysis, the OBW at ACLR$\geq$35 ㏈ shows nearly same statistical characteristics regardless of the measurement locations and environments.