• Title/Summary/Keyword: Reference shape

Search Result 696, Processing Time 0.028 seconds

A Study on Anticipation System of Shudder Distinction by the Physical Shape Alteration in Static Condition (고정상태에서 신체 형태변화에 따른 떨림 판별의 예측시스템 연구)

  • Kim, Jeong-Lae;Choi, Jae-Sil;Hwang, Kyu-Sung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.3
    • /
    • pp.115-120
    • /
    • 2017
  • Moving techniques is made up the physical moving status of the flow distinction modulus (FDM) and stream distinction modulus (SDM) on the shudder moving shape. Condition of the distinction modulus by the shudder moving shape is organized the dangle moving system. As to define the physical moving of special signal on the matter, we compared a shudder value of the flow distinction modulus on the flow state. The concept of stream distinction modulus is analyzed the reference of stream distinction signal and stream distinction signal by the stream state. For detecting a variation of the FDM-SDM of the maximum-minimum and average in terms of the moving shape, and shudder moving value that is a shudder value of the top variation of the $Top-{\varepsilon}$ MAX-MIN-AVG with $(-0.817){\pm}0.15$ units, that is a shudder value of the peripheral variation of the $Per-{\varepsilon}$ MAX-MIN-AVG with $(-2.53){\pm}(-0.11)$ units, that is a shudder value of the limbus variation of the $Lim-{\varepsilon}$ MAX-MIN-AVG with $(-0.29){\pm}0.03$ units, that is a shudder value of the center variation of the $Cen-{\varepsilon}$ MAX-MIN-AVG with $(-0.09){\pm}(-0.01)$ units. The dangle moving will be to assess at the capacity of the physical moving shape for the control degree of distinction modulus on the FDM-SDM that is showed the flow and stream shape by the distinction modulus system. Dangle distinction system is adjusted of a shape by the special moving and is included a shudder data of dangle moving modulus.

The Application of New Calibrator[I-125]Set for Equipment Quality Management (장비정도관리에 Calibrator[I-125] Set 적용)

  • Kim, Ji-Na;An, Jae-seok;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.108-111
    • /
    • 2015
  • Purpose Lately, in accordance with the increasing interest about Healthcare accreditation program and International laboratory accreditation scheme, requirements about the instrument quality management are gradually taking shape. In nuclear medicine In vitro laboratory, the most typical instruments are multi detector gamma counter and automatic dispensing system. Each laboratory continue with the quality control adequate for circumstances. The purpose of this study is to application and establish the new Calibrator[I-125]Set which is efficient at standardization of equipment quality management. Materials and Methods Deviation between detectors were measured with 12 solid samples of the Calibrator[I-125]Set. their activities differ from each other by less than 1%. Multi detector gamma counters are GAMMA-10;Shinjin medics. Inc, Goyansi, Korea(Gamma counter A), SR300;Stratec biomedical systems AG, Gewerbestr, Germany(Gamma counter B) and COBRA II; Packard Instrument Co. Inc, Meriden, USA(Gamma counter C). Evaluation of two automatic dispensing system used A, B liquid tracer of the Calibrator[I-125]Set. After dispensing and counting, calculated using the ratio of the measured value and proposed value. We used solution A for 20, 25ul and solution B for 50, 100ul. Method of data analysis and reference range was provided by kit documentation. Furthermore, we could calculate our counter efficiency indirectly. Results The CV(%) of measured values by Gamma counter A, B, C are 0.34, 0.70, 1.30. Calculated value are 1.05314, 2.10419, 4.08485. Provided reference range is less than 3. A dispensing system's calculated values are 0.986, 0.989, 1.023, 1.017 and B are 0.874, 0.725, 1.021, 0.904. Provided reference range is from 0.95 to 1.05. Also, counter's efficiency are 74.18, 72.79, 74.32% at counter A, B, C and efficiency of the one detector counter is 79.26%. Conclusion If using this Calibrator[I-125]Set after verifying whether quality assurance, is applicable to equipment quality management on behalf of the role of gold standard.

  • PDF

p-Version Finite Element Model of Stiffened Plates by Hierarchic $C^0$-Element (계층적 $C^0$ - 요소에 의한 보강판의 p-Version 유한요소 모델)

  • 홍종현;우광성;신영식
    • Computational Structural Engineering
    • /
    • v.9 no.1
    • /
    • pp.33-45
    • /
    • 1996
  • A general stiffener element which includes transverse shear deformation is formulated using the p-version finite element method. Hierarchic C/sup o/-shape functions, derived from Integrals of Legendre polynomials, are used to define the assembled stiffness matrix of the stiffener with respect to the local reference frame is transformed to the plate reference system by applying the appropriate transformation matrices in order to insure compatibility of displacements at the junction of the stiffener and plate. The transformation matrices which account for the orientation and the eccentricity effects of the stiffener with respect to the plate reference axes are used to find local behavior at the junction of the stiffener and the relative contributions of the plate and stiffener to the strength of the composite system. The results obtained by the p-version finite element method are comared with the results in literatures, especially those by the h-version finite element analysis program, MICROFEAP-II.

  • PDF

The Apparel Sizing System of Early Adolescent Girls - Focusing on Lower Garments - (청소년 전기 여학생의 하의 치수 규격에 관한 연구)

  • Jeong, Hwa-Yeon;Suh, Mi-A
    • The Research Journal of the Costume Culture
    • /
    • v.13 no.5 s.58
    • /
    • pp.671-685
    • /
    • 2005
  • The purpose of this study was to develop a new size range and size interval for early adolescent girls. For this purpose, a total of 529 girls aged between 10 and 14 were measured and data were collected from 42 anthropometric measurements and 41 photographic measurements per a person. SAS 8.1 was used in data analysis including means, standard deviations, and frequency analysis. The stature was divided at 5cm intervals as in KS into 9 sizes from the lowest 130cm to the highest 171cm. If waist circumference were divided at the same intervals, the sizes cannot reflect the body growth of adolescent girls at these ages. Thus this study set intervals between sizes irregularly based on the mean of waist circumference by the type of body shape. Based on the results, this study proposed: for Type A - 6 sizes (140A-58, 145A-54, 145A-62, 150A-58, 150A-62, 155A-62); for Type X- 9 sizes (150X-59, 155X-63, 155X-66, 160X-59, 160X-63, 160X-66, 165X-59, 165X-63, 165X-66): and for Type H - 7 sizes (145H-68, 150H-68, 150H-70, 155H-68, 155H-73, 160H-68, 160H-73). For the sizes selected for each type, reference measurements were decided - centering on items necessary for manufacturing clothes. Reference measurements suggested for lower garments 8 items including waist circumference, hip circumference, slacks length and crotch length. The suggested sizes are distributed in a wider range, so they are considered to be helpful for students to find clothes fitting their bodies.

  • PDF

A Suggestion of the Size-designation for the Underweight Women's Tops in their 20s-30s (2·30대 저체중 여성의 상의 치수체계 제안)

  • Lim, Ji young
    • Fashion & Textile Research Journal
    • /
    • v.15 no.3
    • /
    • pp.423-429
    • /
    • 2013
  • This study helps out-size consumers purchase tops and improve the fitness of unde-weight women in their 20s-30s and by the establishment of a size system. The criteria for subjects in this study were those under 18.5($kg/m^2$) of the BMI; subsequently, a total of 233 females were enrolled. The results were: First, the nominal size for female adult formal dress suggested by the KS standard is suggested in 20 sections. The sections for underweight women are 7, (34 women who accounted for 14.59% out of 233 in total). The cover efficiency was 2.08% (which was very low). Second, tests showed that the average difference between the reference part body size of 7 sections for underweight women in the normal size section of bust cir.- hip cir.- height, and KS standard, waist cir. among reference sizes was rather small in the case of a nominal size for long height. Therefore, there is a significant difference with size in the KS standard and a sizing system proven improper for underweight woman. Third, the basic body sizes and reference body sizes were different due to the size system establishment according to measurements of underweight subjects. The research findings suggest that it is necessary to understand underweight types according to bust girth and hip girth sizes that represent basic sizes as well as to design patterns that consider the underweight body shape characteristics when women's tops are designed.

Orientation Analysis between UAV Video and Photos for 3D Measurement of Bridges (교량의 3차원 측정을 위한 UAV 비디오와 사진의 표정 분석)

  • Han, Dongyeob;Park, Jae Bong;Huh, Jungwon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.6
    • /
    • pp.451-456
    • /
    • 2018
  • UAVs (Unmanned Aerial Vehicles) are widely used for maintenance and monitoring of facilities. It is necessary to acquire a high-resolution image for evaluating the appearance state of the facility in safety inspection. In addition, it is essential to acquire the video data in order to acquire data over a wide area rapidly. In general, since video data does not include position information, it is difficult to analyze the actual size of the inspection object quantitatively. In this study, we evaluated the utilization of 3D point cloud data of bridges using a matching between video frames and reference photos. The drones were used to acquire video and photographs. And exterior orientations of the video frames were generated through feature point matching with reference photos. Experimental results showed that the accuracy of the video frame data is similar to that of the reference photos. Furthermore, the point cloud data generated by using video frames represented the shape and size of bridges with usable accuracy. If the stability of the product is verified through the matching test of various conditions in the future, it is expected that the video-based facility modeling and inspection will be effectively conducted.

Mesh topological form design and geometrical configuration generation for cable-network antenna reflector structures

  • Liu, Wang;Li, Dong-Xu;Jiang, Jian-Ping
    • Structural Engineering and Mechanics
    • /
    • v.45 no.3
    • /
    • pp.411-422
    • /
    • 2013
  • A well-designed mesh shape of the cable net is of essential significance to achieve high performance of cable-network antenna reflectors. This paper is concerned with the mesh design problem for such antenna reflector structure. Two new methods for creating the topological forms of the cable net are first presented. Among those, the cyclosymmetry method is useful to generate different polygon-faceted meshes, while the topological mapping method is suitable for acquiring triangle-faceted meshes with different mesh grid densities. Then, the desired spatial paraboloidal mesh geometrical configuration in the state of static equilibrium is formed by applying a simple mesh generation approach based on the force density method. The main contribution of this study is that a general technical guide for how to create the connectivities between the nodes and members in the cable net is provided from the topological point of view. With the new idea presented in this paper, multitudes of mesh configurations with different net patterns can be sought by a certain rule rather than by empiricism, which consequently gives a valuable technical reference for the mesh design of this type of cable-network structures in the engineering.

A Study on the Development of a Program to Body Circulation Measurement Using the Machine Learning and Depth Camera

  • Choi, Dong-Gyu;Jang, Jong-Wook
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.1
    • /
    • pp.122-129
    • /
    • 2020
  • The circumference of the body is not only an indicator in order to buy clothes in our life but an important factor which can increase the effectiveness healing properly after figuring out the shape of body in a hospital. There are several measurement tools and methods so as to know this, however, it spends a lot of time because of the method measured by hand for accurate identification, compared to the modern advanced societies. Also, the current equipments for automatic body scanning are not easy to use due to their big volume or high price generally. In this papers, OpenPose model which is a deep learning-based Skeleton Tracking is used in order to solve the problems previous methods have and for ease of application. It was researched to find joints and an approximation by applying the data of the deep camera via reference data of the measurement parts provided by the hospitals and to develop a program which is able to measure the circumference of the body lighter and easier by utilizing the elliptical circumference formula.

Effects of Casing Shape on the Performance of a Small-Size Turbo-Compressor (케이싱 형상 변화가 소형 터보압축기 성능에 미치는 영향)

  • 김동원;김윤제
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1031-1038
    • /
    • 2002
  • The effects of casing shape on the performance and interaction between the impeller and casing in a small-size turbo-compressor are investigated. Numerical analysis is conducted for the compressor with circular and single volute casings from inlet to discharge nozzle. In order to predict the flow pattern inside the entire impeller, vaneless diffuer and casing, calculations with multiple frames of reference method between the rotating and stationery parts of the domain are carried out. For compressible turbulent flow fields, the continuity and three-dimensional time-averaged Wavier-Stokes equations are employed. To evaluate the performance of two types of casings, the static pressure and loss coefficients are obtained with various flow rates. Also, static pressure distributions around casings are studied for different casing shapes, which are very important to predict the distribution of radial load. To prove the accuracy of numerical results, measurements of static pressure around casing and pressure difference between the inlet and outlet of the compressor are peformed for the circular casing. Comparisons of these results between the experimental and numerical analyses are conducted, and reasonable agreement is obtained.

A Study on the Evaluation of Sensation Magnitude of Vertical Vibration of a Steering Wheel (조향 휠 수직 진동의 체감량 평가에 관한 연구)

  • Jang, Han-Kee;Hong, Seok-In
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.6
    • /
    • pp.108-113
    • /
    • 2007
  • This study aims to find equivalent comfort contours, reciprocal of frequency weighting curves, for vertical steering wheel vibration. Psychophysical responses were measured from twelve male subjects by using magnitude estimation of relative discomfort due to vertical steering wheel vibrations of magnitude of 0.1 to 1.58 $m/s^2$ in the frequency range of 4 to 250 Hz. Relative discomfort were estimated with a reference vibration of 0.4 $m/s^2$ at 31.5 Hz. Equivalent comfort contours were produced from the median of sensation magnitudes judged by twelve subjects, which showed variation in the shapes with increase of vibration magnitude. A shape of the contour came close to the perception threshold curve with decrease of vibration magnitude. When the vibration magnitude increases, the shape changed close to those in the references of Hong and et al (2003). It is also recommended frequency weighting curves for vertical steering wheel vibration must be expressed as a function of vibration magnitude as well as frequency.