• 제목/요약/키워드: Reference ranges

검색결과 248건 처리시간 0.024초

자동혈압계의 오실레이션 신호를 이용한 혈압 측정 (Measuring Blood Pressure Using Oscillation Signal from an Automatic Sphygmomanometer)

  • 김동준;김영수
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1720-1724
    • /
    • 2012
  • This study describes an oscillometric-based blood pressure measuring algorithm by detecting turning points of oscillation signal from digitally filtered cuff signals of an automatic sphygmomanometer. The blood pressure measuring algorithm uses a characteristic ratios method from the turning points. The accurate values of the systolic/diastolic blood presures(SBP/DBP) are calculated using the peaks in the ranges of characteristic ratios. Performances of the proposed algorithm and four automatic sphygmomanometers are compared with the mercury manometer(manual type sphygmomanometer), regarding the SBP and DBP values of manual sphygmomanometer as the reference values. The performance test showed the proposed algorithm revealed the best results in errors and a statistical analysis. Therefore this algorithm can be usable in any automatic sphygmomanometers.ssure states. This may be compromising results for subject-independent sensibility evaluation using EEG signal.

Voltammetric Assay of Silver Ions in Frog's Tissue

  • Ly, Suw-Young;Lee, Jin-Hui;Lee, Chang-Hyun
    • 한국응용과학기술학회지
    • /
    • 제30권1호
    • /
    • pp.139-145
    • /
    • 2013
  • The electrochemical analysis of silver ion was performed using cyclic voltammetry (CV) and square-wave (SW) stripping voltammetry, and electrode cell systems were fabricated with graphite pencil electrode (GE) of working, reference and counter electrodes. Also electrolyte was the use of sea water as electrolyte solutions instead of ionic controlled solutions. The optimum analytical conditions for the cyclic and stripping parameters were determined using GE. The results approached the microgram working ranges of SW(ug/L) and CV(ug/L) Ag, and the optimum conditions were applied to frog's tissue and the food samples.

On-field Crop Stress Detection System Using Multi-spectral Imaging Sensor

  • Kim, Yunseop;Reid, John F.;Hansen, Alan;Zhang, Qin
    • Agricultural and Biosystems Engineering
    • /
    • 제1권2호
    • /
    • pp.88-94
    • /
    • 2000
  • Nitrogen (N) management is critical for corn production. On the other hand, N leaching into the groundwater creates serious environmental problems. There is a demand for sensors that can assess the plant N deficiency throughout the growing season to allow producers to reach their production goals, while maintaining environmental quality. This paper reports on the performance of a vision-based reflectance sensor for real-time assessment of N stress level of corn crops. Data were collected representing the changes in crop reflectance in various spectral ranges over several stages of development in the growing season. The performance of this non-contact sensor was validated under various field conditions with reference measurement from a Minolta SPAD meter and stepped nitrogen treatments.

  • PDF

나선형 단층 방사선사진에서 치조정 판독 신뢰도 (Reliability of spiral tomography on the alveolar crest)

  • 윤숙자
    • Imaging Science in Dentistry
    • /
    • 제34권3호
    • /
    • pp.123-128
    • /
    • 2004
  • Purpose: To evaluate the reliability of measurements in spiral tomography through assessing the visibility of the alveolar crest and the measurements between the alveolar crest and other anatomic structures. Materials and Methods: 110 spiral tomograms of the jaws were taken by Scanora X-ray unit from the patients. The visibility of the alveolar crests was estimated by 3 observers and classified as clearly visible, questionable visibility, or not visible. 3 observers measured the distance between the alveolar crest and the reference points of anatomic structures. The measurements were repeated 2 weeks later. Results: 52.9% of alveolar crests on upper jaws and 61.5% of alveolar crests on lower jaws were visible. The interobserver and intraobserver agreements on the visibility were low. The mean ranges of the measurements were 1.39 mm (SD = 1.37 mm) on maxilla and 1.03 mm (SD = 1.01 mm) on mandible in the interobserver evaluation. The interobserver variance was greater than the intraobserver variance in the measurements of distance. Conclusion: Spiral tomography showed a relatively low reliability in the visibility and measurements of the alveolar crest.

  • PDF

최대 비트슬립 정정범위를 가지는 복합 버스트 동기/에러 검출 시스템 (Combined burst synchronization/error detection systems maximizing bit slip correction ranges)

  • 최양호
    • 한국통신학회논문지
    • /
    • 제22권7호
    • /
    • pp.1477-1486
    • /
    • 1997
  • Conventioally the decoding methods and the design of coset codes for burst synchronization and error detection have been based on the concept that slips occuring to the right or to the left with respect to a reference timing are corrected. In this paper we newly approach to the design of coset codes relying on the condition that only a single code word can exists in an observation interval, which provides an extentended view on the conventional approach. A theorem concerning the condition is presented. A combined burst synchronization and error detection system with maximum slip correction capability have been devised based on the theorem and a detection method is falsely accepted in the presented of channel errors. The false acceptance probabilities of the system are derived and its performance is analyzed through computer computation using the derived results.

  • PDF

운전조건 변화에 따른 소방펌프 성능특성 연구 (A Study on the Performance Characteristic of a Fire Pump with Various Operating Conditions)

  • 박성규;노고섭;김윤제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2011-2016
    • /
    • 2004
  • In order to develop a high efficiency fire pump, its performance characteristics with various operating conditions are investigated. The governing equations are derived from making using of three-dimensional Navier-Stokes equations with the standard ${\kappa}-{\varepsilon}$ turbulence model and SIMPLE algorithm. Using a commercial code, CFX, pressure distribution and flow fields in a fire pump are calculated with various ranges of rotating speed 800-2400 rpm. Particularly, calculations with multiple frames of reference method between the rotating and stationary parts of the domain are carried out. With the help of numerical results, correlation formula between the casing pressure and the efficiency is derived.

  • PDF

Design of sliding-type base isolators by the concept of equivalent damping

  • Yang, Yeong-Bin;Chen, Yi-Chang
    • Structural Engineering and Mechanics
    • /
    • 제8권3호
    • /
    • pp.299-310
    • /
    • 1999
  • One problem with base isolators of the sliding type is that their dynamic responses are nonlinear, which cannot be solved in an easy manner, as distinction must be made between the sliding and non-sliding phases. The lack of a simple method for analyzing structures installed with base isolators is one of the obstacles encountered in application of these devices. As an initial effort toward simplification of the analysis procedure for base-isolated structures, an approach will be proposed in this paper for computing the equivalent damping for the resilient-friction base isolators (R-FBI), based on the condition that the sum of the least squares of errors of the linearized response with reference to the original nonlinear one is a minimum. With the aid of equivalent damping, the original nonlinear system can be replaced by a linear one, which can then be solved by methods readily available. In this paper, equivalent damping curves are established for all ranges of the parameters that characterize the R-FBI for some design spectra.

Generation of Water and Steam Properties for LWR

  • Jun, Byung-Jin;Lee, Chang-Kun;Lee, Ji-Bok;Chang, Jong-Hwa
    • Nuclear Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.180-193
    • /
    • 1980
  • 경수의 엔탈피, 비체적(比體積), 점성, 열전도도 및 임계엔트로피등은 경수로의 핵특성 분석에 필수적인 자료이다. 본 보고서에서는 상기 자료를 신속, 정확하게 구할 수 있는 부(副)프로그램을 개발하여 경수로의 핵계산코드에서 보편적으로 사용할 수 있게 하였다. 기본자료로 ASME Steam Tables (1967)과 이의 개정판 (1975)을 사용하였다. 경수로의 핵계산에서 사용되는 온도 및 압력의 영역에서 이 프로그램의 계산치는 기준치와 오차 0.2%내에 들어 있음이 입증되었다.

  • PDF

Automatic Generation of a SPOT DEM: Towards Coastal Disaster Monitoring

  • Kim, Seung-Bum;Kang, Suk-Kuh
    • 대한원격탐사학회지
    • /
    • 제17권2호
    • /
    • pp.121-129
    • /
    • 2001
  • A DEM(digital elevation model) is generated from a SPOT panchromatic stereo-pair using automated algorithms over a 8 km$\times$10 km region around Mokpo city. The aims are to continue the accuracy assessment over diverse conditions and to examine the applicability of a SPOT DEM for coastal disaster monitoring. The accuracy is assessed with respect to three reference data sets: 10 global positioning system records, 19 leveling data, and 1:50,000 topography map. The planimetric error is 10.6m r.m.s. and the elevation erroer ranges from 12.4m to 14.4m r.m.s.. The DEM accuracy of the flat Mokpo region is consistent with that over a mountainous area, which supports the robustness of the algorithms. It was found that coordinate transformation errors are significant at a few meters when using the data from leveling and topographic maps. The error budget is greater than the requirements for coastal disaster monitoring. Exploiting that a sub-scene is used, the affine transformation improves the accuracy by 50% during the camera modeling.

Design and Implementation of Damaged Video File Recovery Tool using Container Format Structure

  • Choi, Yun-Seok;Lee, Wan Yeon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제11권3호
    • /
    • pp.64-70
    • /
    • 2019
  • Video files of video devices such as black box and CCTV may be damaged due to repetitive file read / write and physical environment factors. Even though there are available parts of video information, it may happen that playback can't be performed due to damage of some information. To playback the remaining video information normally, it is necessary to recover damaged areas of the files. For this, it is necessary to accurately check the damage range of the files. In this paper, we propose the design and implementation of a tool which detects damaged areas of a video file and recovers the usable area of the file to playback. The proposed tool can analyze and recover without additional information by analyzing common information of video container format and can check detailed damaged ranges with chunks. It is possible to perform recovery just only with the target file and reference file without any other information such as codec specification.