• Title/Summary/Keyword: Reference phase

검색결과 1,366건 처리시간 0.04초

Analysis of Decoupling Method in DQ Transform-based for Grid Connected Inverter

  • Windarko, Novie Ayub;Lee, Jin-Mok;Choi, Jae-Ho
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.924-925
    • /
    • 2008
  • There are many types of grid-connected inverter controllers, PI controller based is the most popular methods. But, a common PI control is produced zero-steady state error and phase delay in sinusoidal reference. Synchronous reference frame or DQ transform based controller is capable for reducing both of zero-steady state error and phase delay is. But DQ transform based controller has cross-coupling component which difficult to analyze the system in single phase model. In this paper, to obtained single phase model of the system, DQ transform based controller is analyzed in two techniques. The first is by neglecting cross-coupling. The second is eliminated cross-coupling component by decoupling method. By these two techniques, single phase model is obtained. Then, the single phase model is analyzed to evaluate its performance in stability and frequency response, through Root Locus and Bode diagram, respectively. MATLAB and PSIM simulation is used to verify the analysis. Simulation result is shown; cross-coupling component has no significant influent to the controller.

  • PDF

우리나라 조석지각 기준 표기에 대한 고찰 (Overview of Tidal Phase-lag References Used in Korea)

  • 변도성
    • 한국해양학회지:바다
    • /
    • 제12권3호
    • /
    • pp.234-238
    • /
    • 2007
  • 현재까지 우리나라에선 연구자마다 각기 다른 세 가지 조석지각 기준(관측지점 경도 기준 지각, 표준시 자오선 기준 지각, 그리니치 자오선 기준 지각)을 사용하여 오고 있다. 이처럼 통일되지 않는 조석지각 정보체계는 전체적인 우리나라 조석의 특성이나 변화를 이해하는데 장애가 되고 있다. 이 연구에서는 올바른 조석지각 기준의 상호전환과 관련하여, 세 가지 지각기준에 관하여 자세히 살펴보았다. 이에 앞서 조석 조화분해 과정에서 분조의 지각이 어떻게 계산되며, 조석예측프로그램에선 계산된 지각이 어떻게 사용되게 되는지 살펴보았다. 또한 이것을 바탕으로 과거 일부 연구에서 불명확하게 기술된 조석지각의 정의에 관하여 논의하였다.

Geodetic Survey Campaigns and Maintenance Plan for KASS Reference Station Antenna Coordinates

  • Hwanho, Jeong;Hyunjin, Jang;Youngsun, Yun;ByungSeok, Lee
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제12권1호
    • /
    • pp.83-89
    • /
    • 2023
  • The Korea Augmentation Satellite System (KASS) system is a Satellite Based Augmentation System (SBAS) under development to provide APV-I SBAS service in the Republic of Korea. The KASS ground segment generates correction and integrity information for GPS measurements of KASS users using the accurate positions of KASS Reference Station (KRS) antenna phase centers. For this reason, the accuracy of KRS reference points through geodetic survey campaigns is one of the important factors for providing the KASS service in compliance with the required navigation performance. In order to obtain accurate positions, two geodetic survey campaigns were performed at several reference points, such as Mark, Center of Mast at Ground Level (CMGL), and Center of Hole in Top Plate (CHTP), of each KRS site using three different survey methods, the Virtual Reference Station (VRS), Flächen Korrektur Parameter (FKP), and raw data post-processing methods. By comparing and analyzing the results, the computed coordinates of the reference points were verified and Antenna Phase Center (APC) positions were calculated using KRS Antenna Reference Point (ARP) data, and the first KASS Site Acceptance Test (SAT#1) was performed successfully using the verified APC coordinates. After the first site survey activities, the KASS operators should maintain the coordinates with the required performance such that the overall KASS navigation performance commitment is guaranteed during the lifetime of 15 years. Therefore, the maintenance plan for the KRS antenna coordinates should be developed before the commissioning of KASS operation planned after 2023. Therefore, this paper presents a geodetic survey method selected for the maintenance activities and provides the rationale for using this method.

UPS 용 3상 인버터의 LC필터단 출력전압 제어 방식 비교연구 (A Comparative Study on the Output Voltage Control Strategies of Three Phase Inverter with LC Filter for UPS)

  • 나운기;김태완;정승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.312-317
    • /
    • 1996
  • This paper compares the output voltage control strategies of three-phase PWM inverter for uninterruptible power supply. The feedforward control, feedforward/feedback control, and decoupled feedback control in both the synchronous reference frame and the stationary reference frame are examined. In particular, it is shown that the response of the decoupled feedback controller in the synchronous reference frame can be improved by pole-zero cancellation method. It is also shown that the pole-zero cancellation method reduces to the deadbeat control, when it is implemented with digital controller.

  • PDF

FPGA Based PWM Generator for Three-phase Multilevel Inverter

  • ;전태원;김흥근;노의철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.225-227
    • /
    • 2008
  • This paper deals with the implementation on a Field Programmable Gate Array (FPGA) of PWM switching patterns for a voltage multilevel inverter. The reference data in main microcontroller is transmitted to the FPGA through 16 general purpose I/O ports. Herein, three-phase reference voltage signals are addressed by the last 2-bit (bit 15-14) and their data are assigned in remaining 14-bit, respectively. The carrier signals are created by 16-bit counter in up-down counting mode inside FPGA according to desirable topology. Each reference signal is compared with all carrier signals to generate corresponding PWM switching patterns for control of the multilevel inverter. Useful advantages of this scheme are easy implementation, simple software control and flexibility in adaptation to produce many PWM signals. Some simulations and experiments are carried out to validate the proposed method.

  • PDF

Sliding Mode Tracking Control of a Nonminimum Phase EGR/VGT Diesel Engine

  • J., Heon Sul;Utkin, V.I.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1999년도 제14차 학술회의논문집
    • /
    • pp.104-107
    • /
    • 1999
  • Tracking control of an arbitrary reference has been discussed for 7Th order 2-input 2-output non-minimum phase EGR/VGT diesel engines. To meet strict emission regulations and customer demands, the desired set points, the air-fuel ratio and the ERG flow fraction, determined from a static engine data based on engine speed and the desired fueling rate are transformed into the set points for the two sensor measurement outputs. Applying the sliding mode tracking control theory proposed by Jeong and Utkin, two step design was carried out using the bounded solution of an unstable zero dynamics for the given reference signals. This paper shows through simulations how stabilization of unstable zero dynamics and reference tracking can be accomplished simultaneously.

  • PDF

Inductance Measurement of Interior Permanent Magnet Synchronous Motor in Stationary Frame of Reference

  • Lee, Geun-Ho;Choi, Woong-chul;Lee, Byeong-Hwa;Jung, Jae-Woo;Hong, Jung-Pyo
    • Journal of Magnetics
    • /
    • 제16권4호
    • /
    • pp.391-397
    • /
    • 2011
  • An inductance measurement method for interior permanent magnet synchronous machine (IPMSM) is proposed in this paper. In this method, the motor is measured at standstill condition, and only a 3-phase voltage source, an oscilloscope and a DC voltage source are required. Depending on the deductive dq-axis voltage equations in the stationary frame of reference, the dq-axis inductances at different current magnitude and vector angle can be calculated by the measured 3-phase voltages and currents. And hence, the saturation and cross-magnetizing effect of the inductances are measurable. This paper introduces the principle equations, experiment setup, data processing, and results comparison on the concentrated-winding and distributed-winding IPMSMs.

비최소 위상 시스템에 대한 기준 모델 적응 폴-플레이스먼트 제어기 (Model Reference Adaptive Pole-Placement Controller of Nonminimum Phase systems)

  • 김종환;최계근
    • 대한전자공학회논문지
    • /
    • 제22권6호
    • /
    • pp.89-96
    • /
    • 1985
  • 단일 입·출력 시불변 비최소 위상 공정에 대한 폴-플레이스먼트 제어기를 기준 모델을 사용하여 설계하였다. 제안된 폴-플레이스먼트 제어기는 변수 다항식5(q-1)만을 사용하여 파라미터 형으로 나타내어 기준모델의 전달함수와 제어기의 전달함수를 같게 하는 방법을 사용하였다. 또한, 적응 폴-플레이스먼트 제어기는 위의 제어기에 적응 알고리즘을 적응하여 제어기의 파라미터를 추정 하도록 설계 되었다.

  • PDF

고스트 신호 제거기용 애널러그 위상변위기 설계 (Design of the analog phase shifter for the ghost signal elimination)

  • 주성호;김동현;이상설
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.825-828
    • /
    • 1999
  • In this paper, we design the analog phase shifter for the elimination of the ghost signal. Compensation of the delay between the reference signal and the relatively delayed signal is possible. This phase shifter uses the vector summing method. We use for the attenuator in our system FETs. The phase shifter is operated at the 200MHz and composed by lumped elements. The proposed analog phase shifter is simulated by the HP ADS software.

  • PDF

스위칭 손실 저감을 위한 기준전류 기울기를 이용한 단상 히스테리시스 전류 제어에 관한 연구 (A Study of Single Phase Hysteresis Current Control Using Reference Current Slope for Reducing Switching Loss)

  • 홍선기
    • 조명전기설비학회논문지
    • /
    • 제23권1호
    • /
    • pp.150-155
    • /
    • 2009
  • 히스테리시스 전류 제어방식은 원리와 구조가 간단하여 널리 사용되었으나, 전류 오차 허용 밴드폭이 너무 작거나, 전원 전압이 상대적으로 너무 큰 경우 등에는 스위칭 주파수가 급격히 증가하여 많은 열을 발생할 수 있는 등의 단점이 있었다. 이에 본 연구에서는 단상 전류제어에서 0 모드를 추가하고, 기준 전류의 기울기를 비교하여 히스테리시스 전류 제어를 수행함으로써 대폭적인 스위칭 주파수 감소와 안정적인 전류제어가 가능하게 하였다. 또한 이를 컴퓨터 시뮬레이션을 통해 그 타당성을 확인하였다.