• Title/Summary/Keyword: Reference generator

Search Result 312, Processing Time 0.029 seconds

A Study on the Optimal Parameter Selection of a Power System Stabilizer for HVDC Linked System (HVDC 연계 시스템의 전력계통 안정화 장치의 적정 파라메터 선정에 관한 연구)

  • 김경철;최홍규;최병숙;강태은;고영곤
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.5
    • /
    • pp.81-89
    • /
    • 2001
  • Power system stabilizer act efficiently to damp the electromechanical oscillations in interconnected power systems. This paper presents an algorithm for the optimal parameter selection of a power system stabilizer in two-area power systems with a series HVDC link. This method is one of the classical techniques by allocating properly pole-zero positions to fit as closely as desired the ideal phase lead between the voltage reference and the generator electrical power and by changing the gain to produce a necessary damping torque over the matched frequency range. The small signal stability and transient stability studies using the PSS parameters obtained from this method show that a natural oscillation frequency of the study case system is adequately damped. The simulation used in the paper was performed by the Power System Toolbox software program based on MATLAB.

  • PDF

Turbine Alignment (II): Computer Program Development (발전설비의 터빈 축정렬 (II) : 자동화를 위한 전산 프로그램 개발)

  • Hwang, Cheol-Ho;Kim, Jeong-Tae;Jun, Oh-Sung;Lee, Hyun;Lee, Byung-Jun
    • Journal of KSNVE
    • /
    • v.4 no.1
    • /
    • pp.33-42
    • /
    • 1994
  • When a vibration is generated due to the misalignment, the reduction of the vibration level is not attainable unless a correct shaft alignment is conducted. In a turbine system, an alignment procedure requires quite a lot amount of expense and time. To reduce this effort, an algorithm of the turbine alignment is developed to be used in the computer program. The program consists of five parts : input, calculation, display of the results, file management, and printer output. In the input part, users must provide the data on the turbine number, the reference value of the alignment, and the number of the feet of the generator. In calculation, the moving distance of the bearing and the necessary amount of the shims are calculated. In the display and the output parts, the calculated results are displayed and calculated. In the display and the output parts, the calculated results are displayed and printed. Then, by using the file management, results and procedures conducted are saved in the floppy diskette or in the hard disk. The developed program can be run in IBM PC compatible with more than 640 KB of main memory with the operating system of MS-DOS v 3.3 or higher. It is developed for novice users with no experience or specialty in this field. The program is not only useful in the power plant application, but also helpful for recording of the alignment procedures.

  • PDF

Visualization of Smoke Flow in the Subway Fire (지하철 화재발생시 역사내 화재연기 거동 가시화 연구)

  • Choi Chang Jin;Jung Hae Gon;Kim Sang Moon;Kim Kyung Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.64-68
    • /
    • 2005
  • In this study, the smoke flows of the inner subway station were visualized through a numerical analysis and visualization experiment in the subway fire. A transparent acrylic model was designed and installed as 1:25th scale-down as the actual subway station by using geometrical similarity The properties of subway fire were reconstructed according to Densimetric Froude Similarity. The 47 to 53 ratio of the mixed air and Helium was inputted in the inner acrylic model to describe 1MW fire intensity with reference to the experiment paper. For the same time, the fire smoke from a smoke generator was inputted in the inner acrylic model with the mixture. At this time, the buoyancy effect of Helium gas went up the smoke to the acrylic model. When the sheet beam of Ar-lon laser was given out to the top and stair of subway model, the digital camcorder took the images of the scattered cluster of smoke particles when applying the smoke management system and PSD.

  • PDF

Enhanced Controller Topology for Photovoltaic Sourced Grid Connected Inverters under Unbalanced Nonlinear Loading

  • Sivakumar, P.;Arutchelvi, Meenakshi Sundaram
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.369-382
    • /
    • 2014
  • A growing dynamic electrical demand has created an increasing interest in utilizing nonconventional energy sources like Photovoltaic (PV), wind power, etc. In this context, this paper focuses on the design and development of a composite power controller (CPC) in the decoupled double synchronous reference frame (DDSRF) combining the advantages of direct power control (DPC) and voltage oriented control (VOC) for a PV sourced grid connected inverter. In addition, a controller with the inherent active filter configuration is tested with nonlinear and unbalanced loads at the point of common coupling in both grid connected and autonomous modes of operation. Furthermore, the loss and reactive power compensation due to a non-fundamental component is also incorporated in the design, and the developed DDSRF model subsequently allows independent active and reactive power control. The proposed developed model of the controller is also implemented using MATLAB-Simulink-ISE and a Xilinx system generator which evaluate both the simulated and experimental setups. The simulation and experimental results confirm the validity of the developed model. Further, simulation results for the DPC are also presented and compared with the proposed CPC to further bring out the salient features of the proposed work.

Flexible Voltage Support Control with Imbalance Mitigation Capability for Inverter-Based Distributed Generation Power Plants under Grid Faults

  • Wang, Yuewu;Yang, Ping;Xu, Zhirong
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1551-1564
    • /
    • 2016
  • The high penetration level of inverter-based distributed generation (DG) power plants is challenging the low-voltage ride-through requirements, especially under unbalanced voltage sags. Recently, a flexible injection of both positive- (PS) and negative-sequence (NS) reactive currents has been suggested for the next generation of grid codes. This can enhance the ancillary services for voltage support at the point of common coupling (PCC). In light of this, considering distant grid faults that occur in a mainly inductive grid, this paper proposes a complete voltage support control scheme for the interface inverters of medium or high-rated DG power plants. The first contribution is the development of a reactive current reference generator combining PS and NS, with a feature to increase the PS voltage and simultaneously decrease the NS voltage, to mitigate voltage imbalance. The second contribution is the design of a voltage support control loop with two flexible PCC voltage set points, which can ensure continuous operation within the limits required in grid codes. In addition, a current saturation strategy is also considered for deep voltage sags to avoid overcurrent protection. Finally, simulation and experimental results are presented to validate the effectiveness of the proposed control scheme.

A Risk Impact Assessment According to the Reliability Improvement of the Emergency Power Supply System of a Nuclear Power Plant (원자력발전소 비상전력계통 강화 방안에 따른 리스크 영향 평가)

  • Jeon, Ho-Jun
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.5
    • /
    • pp.224-228
    • /
    • 2012
  • According to the results of Probabilistic Safety Assessment(PSA) for a Nuclear Power Plant(NPP), an Emergency Power Supply(EPS) system has been considered as one of the most important safety system. Especially, the interests in the reliability of the EPS system have been increased after the severe accidents of Fukushima Daiichi. Firstly, we performed the risk assessment and the importance analysis of the EPS system based on the PSA models of the reference plant, which is the Korean standard NPP type. Considering a portable Diesel Generator(DG) system as the reliability reinforcement of the EPS system, we modified the PSA models and performed the risk impact assessment and the importance analysis. Although the reliability of the potable DG could be about 20% of the reliability of the alternative AC DG, we identified that Core Damage Frequency(CDF) was decreased by at least 4.6%. In addition, the risk impacts due to the unavailability of the EPS system on CDF were decreased.

Design Parameter Optimization of Liquid Rocket Engine Using Generic Algorithms (유전알고리즘을 이용한 액체로켓엔진 설계변수 최적화)

  • Lee, Sang-Bok;Kim, Young-Ho;Roh, Tae-Seoung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.127-134
    • /
    • 2011
  • A genetic algorithm (GA) has been employed to optimize the major design variables of the liquid rocket engine. Pressure of the main combustion chamber, nozzle expansion ratio and O/F ratio have been selected as design variables. The target engine has the open gas generator cycle using the LO2/RP-1 propellant. The gas properties of the combustion chamber have been obtained from CEA2 and the mass has been estimated using reference data. The objective function has been set as multi-objective function with the specific impulse and thrust to weight ratio using the weight method. The result shows about 4% improvement of the specific impulse and 23% increase of the thrust to weight ratio. The Pareto frontier line has been also obtained for various thrust requirements.

  • PDF

Analysis of Impulse Withstand Voltage Performance of Lighting Equipment (조명기기의 임펄스내전압 성능의 분석)

  • Lee, Bok-Hee;Pang, Pyung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.3
    • /
    • pp.91-96
    • /
    • 2014
  • Modern electronic circuits are becoming more vulnerable to damage by surges, and it is required to improve the impulse withstand voltage performance of electrical and electronic equipment. This paper presents the impulse withstand voltage performance of lighting equipment connected to power lines, and the impulse withstand voltage tests for fluorescent lamp, LED lamp and halogen lamp were carried out according to the reference standards under normal service conditions. To conduct performance tests against lightning surge, a combination wave ($1.2/50{\mu}s$ voltage - $8/20{\mu}s$ current) was employed. The test surge was applied between lines or between line and ground of the specimen to be measured. The test surge was applied synchronized at the peak value of the positive and negative AC voltage waves. As a consequence, some specimens satisfied the impulse withstand voltage test criteria, but lighting equipment such as 36W fluorescent lamps, 5W and 5.5W LED lamps and 50W halogen lamp were damaged at the test voltage levels between power lines. It is needed to improve the qualities of lighting equipment to satisfy EMC immunity requirements of equipment for general lighting purposes.

Power Spectra of the Hybrid Random PWM(HRPWM) Technique Adopting a Random Triangular Carrier (랜덤 삼각파 캐리어를 적용한 하이브리드 랜덤 PWM(HRPWM)방식의 파워 스펙트럼)

  • Kim Ki-Seon;Lim Young-Cheol;Park Sung-Jun;Kim Kwang-Heon;Jung Young-Gook
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.501-507
    • /
    • 2005
  • This paper proposes a Hybrid Random PWM(HRPWM) technique using a LF2407 DSP board in order to spread the power spectra of an induction motor. The proposed method is composed to the PRBS (Pseudo-Random Binary Sequence) with the Lead-Lag random bit and the random triangular carrier for the logical comparison. Also, a DSP generates the random number, the PRBS and the three-phase reference signal, a MAX038 chip operating as frequency modulator generates the random triangular carrier. For verification of the proposed method, the experiments were conducted with a three-phase adjustable speed a.c drives, and the results of simulations and experiments are presented.

An Analysis of Launch Vehicle Development Strategy of SpaceX (SpaceX의 발사체 개발 전략 분석)

  • Lee, Keum-Oh
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.6
    • /
    • pp.72-86
    • /
    • 2019
  • SpaceX is currently leading the global launch market with the successful launch and recovery of Falcon 9 v1.2 Block 5. SpaceX developed Merlin engine, a kerosene gas generator engine, and continuously upgraded the engine from Falcon 1 to Falcon Heavy to increase payload weight. SpaceX suffered a lot of failures early on, but with the help of NASA, it was possible to overcome many crises and develop vehicles. In addition, it successfully developed reusable vehicles, which drastically reduced operating costs. Subsequent launch vehicles in Korea also need to be developed with reference to SpaceX's development strategy.