• 제목/요약/키워드: Reference flow

검색결과 804건 처리시간 0.028초

수질오염총량관리 단위유역 유량자료와 하천유량 측정망 자료의 연계성 분석 (Relationship between the Flow data on the Unit Watersheds and on the Stream Flow Monitoring Network)

  • 박준대;오승영
    • 한국물환경학회지
    • /
    • 제29권1호
    • /
    • pp.55-65
    • /
    • 2013
  • It is very difficult to apply stream flow data directly to the management of Total Maximum Daily Loads because there are some differences between the unit watershed and the stream flow monitoring network in their characteristics such as monitoring locations and its intervals. Flow duration curve can be developed by linking the daily flow data of stream monitoring network to 8 day interval flow data of the unit watershed. This study investigated the current operating conditions of the stream flow monitoring network and the flow relationships between the unit watershed and the stream flow monitoring network. Criteria such as missing and zero value data, and correlation coefficients were applied to select the stream flow reference sites. The reference sites were selected in 112 areas out of 142 unit watersheds in 4 river basins, where the stream flow observations were carried out in relatively normal operating conditions. These reference sites could be utilized in various ways such as flow variation analysis, flow duration curve development and so on for the management of Total Maximum Daily Loads.

건설재료의 안전적 제어를 위한 표준물질 (Standard Reference Materials) 도출 (Study on the Development of Standard Reference Materials for Safety Control of Construction Materials)

  • 이동규;이건우;최명성
    • 한국안전학회지
    • /
    • 제32권5호
    • /
    • pp.54-61
    • /
    • 2017
  • The purpose of this study is to develop standard reference materials for safety control of construction materials considering the required performance of standard materials including flow performance incorporating particles. The flow characteristics of concrete are very complicated depending on mixing proportions of constituent materials, admixtures, amount of mixing, type of mixer, time of mixing, temperature and so forth. Uncertainties and multidimensional properties of concrete have been evaluated through various studies but there are few researches for the development of standard reference material. In this study, based on the rheological concept, the flow performance of construction materials was evaluated to understand the properties of standard reference materials and was finally obtained representing materials which simulate the standard reference materials.

엔진 고공 시험에서 연료 유량 측정용 터빈 유량계의 측정 불확도 분석 (Measurement Uncertainty Analysis of a Turbine Flowmeter for Fuel Flow Measurement in Altitude Engine Test)

  • 양인영
    • 한국유체기계학회 논문집
    • /
    • 제14권1호
    • /
    • pp.42-47
    • /
    • 2011
  • Measurement uncertainty analysis of fuel flow using turbine flowmeter was performed for the case of altitude engine test. SAE ARP4990 was used as the fuel flow calculation procedure, as well as the mathematical model for the measurement uncertainty assessment. The assessment was performed using Sensitivity Coefficient Method. 11 parameters involved in the calculation of the flow rate were considered. For the given equipment setup, the measurement uncertainty of fuel flow was assessed in the range of 1.19~1.86 % for high flow rate case, and 1.47~3.31 % for low flow rate case. Fluctuation in frequency signal from the flowmeter had the largest influence on the fuel flow measurement uncertainty for most cases. Fuel temperature measurement had the largest for the case of low temperature and low flow rate. Calibration of K-factor and the interpolation of the calibration data also had large influence, especially for the case of very low temperature. Reference temperature, at which the reference viscosity of the sample fuel was measured, had relatively small contribution, but it became larger when the operating fuel temperature was far from reference temperature. Measurement of reference density had small contribution on the flow rate uncertainty. Fuel pressure and atmospheric pressure measurement had virtually no contribution on the flow rate uncertainty.

MIRA Notchback Reference Car 표면유동가시화 (Surface Flow Visualization of MIRA Notchback Reference Car)

  • 전중환;김용환;조광륜;노상길;이응호
    • 대한기계학회논문집B
    • /
    • 제24권10호
    • /
    • pp.1309-1316
    • /
    • 2000
  • A surface flow visualization of a MIRA notchback reference car was conducted using a 1/4 -scale model in the POSTECH wind tunnel. The flow separation and reattachment phenomen a around A-pillar, C-pillar, backlight, and trunk were discussed with the help of the distributions of singular points such as nodes, saddles, and spiral foci. The locations of the singular points on the trunk and the backlight from experimental results are compared with those of CFD results using the turbulence modeling of RNG k -${\varepsilon}$ and RSM.

혼합탱크 내의 임펠라 형태에 따른 유동 특성에 관한 수칙해석 (Numerical Study on Flow Patterns of Impeller's Type in a Stirred Tank)

  • 오석영;송길섭
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.454-459
    • /
    • 2001
  • The present study is concerned with the flow patterns induced by other impellers in a rectangular tank Impellers are FBT(Flat blade turbine), PBT(Pitched blade turbine), Shroud turbine, Rushton Turbine, and Helical ribbon turbine. The solution of flows in moving reference frames requires the use of 'moving' cell zone. The moving zone approaches are MRF(Multiple reference frame), which is a steady-state approximation and Sliding method, which is a unsteady-state approximation. Numerical results using two moving zone approaches are compared with experiments by Ranade & Joshi, which have done extensive LDA measurements of the flow generated by a standard six-bladed Rushton turbine in a cylindrical baffled vessel. In this paper we simulated the flow patterns with above mentioned moving zone approaches and impellers. Turbulence model is RNG k-$\epsilon$ model.

  • PDF

반도체 칩 테스트용 챔버 형상에 따른 유동 균일성에 대한 수치적 연구 (A Numerical Study on the Flow Uniformity according to Chamber Shapes Used for Test of the Semi-Conductor Chip)

  • 이대규;마상범;김성;김정열;강채동;김진혁
    • 한국수소및신에너지학회논문집
    • /
    • 제31권5호
    • /
    • pp.480-488
    • /
    • 2020
  • This study was conducted to improve the flow uniformity inside the chip tester through changing the flow path formation according to the inlet and outlet position of chamber. The internal flow and velocity distributions of the modified chamber models (Cases 1-3) were compared with the reference chamber model through three-dimensional Reynolds-averaged Navier-Stokes equations with k-ε turbulence model. The modified chamber models showed the superior flow uniformity characteristics compared to the reference chamber model. To investigate the flow uniformity in the chip tester, the standard deviation of the velocity was defined and compared. Through the internal flow analysis and assesment of the standard deviation, Case 2 among the test cases including the reference model showed the best flow uniformity generally.

트랙터의 전자유압식(電子油壓式) 히치제어 시스템에 관한 연구(硏究)(I) -위치제어(位置制御)- (Electronic-Hydraulic Hitch Control System for Agricultural Tractor -Position Control-)

  • 유수남;류관희;박준걸
    • Journal of Biosystems Engineering
    • /
    • 제14권3호
    • /
    • pp.168-180
    • /
    • 1989
  • This study was attempted to develop the electronic-hydraulic hitch control system for position control of tractor plow and investigate the control performance of the system through experiments. Experiments were carried out to investigate the responses of the system to the step and sinusoidal inputs in position control. The effects of control mode, hydraulic flow rate, reference deadband, and proportional constant on control performance of the system were investigated. The following conclusions were derived from the study; 1. For the position control system operated on on-off control mode, positions of implement were controlled within ${\pm}0.73^{\circ}{\sim}{\pm}1.46^{\circ}$ in rockshaft angle to the reference position when the hydraulic flow rates were 5~15 l/min. For the position control system operated on PWM control mode, positions of implement were controlled within ${\pm}0.73^{\circ}$ to the reference position regardless of hydraulic flow rates. It means that the implement could be positioned more accurately to the reference position on PWM control mode than on on-off control mode. 2. As results of the frequency responses of the position control systems, no clear difference in control performance between on-off control and PWM control modes was found. As the hydraulic flow rates increased, the corner frequencies of amplitude attenuation and phase-angle change increased. It means that the control performance of the system could be improved as the hydraulic flow rate increases.

  • PDF

수질오염총량관리를 위한 4대강수계 장기유황곡선 작성방안 (Development of Long Term Flow Duration Curves in 4 River Basins for the Management of Total Maximum Daily Loads)

  • 박준대;오승영
    • 한국물환경학회지
    • /
    • 제29권3호
    • /
    • pp.343-353
    • /
    • 2013
  • Flow duration curve (FDC) can be developed by linking the daily flow data of stream flow monitoring network to 8-day interval flow data of the unit watersheds for the management of Total Maximum Daily Loads. This study investigated the applicable method for the development of long term FDC with the selection of the stream flow reference sites, and suggested the development of the FDC in 4 river basins. Out of 142 unit watersheds in 4 river basins, 107 unit watersheds were shown to estimate daily flow data for the unit watersheds from 2006 to 2010. Short term FDC could be developed in 64 unit watersheds (45%) and long term FDC in 43 unit watersheds (30%), while other 35 unit watersheds (25%) were revealed to have difficulties in the development of FDC itself. Limits in the development of the long term FDC includes no stream monitoring sites in certain unit watersheds, short duration of stream flow data set and missing data by abnormal water level measurements on the stream flow monitoring sites. To improve these limits, it is necessary to install new monitoring sites in the required areas, to keep up continuous monitoring and make normal water level observations on the stream flow monitoring sites, and to build up a special management system to enhance data reliability. The development of long term FDC for the unit watersheds can be established appropriately with the normal and durable measurement on the selected reference sites in the stream flow monitoring network.

용담댐 운영이 하류 기준유량 설정에 미치는 영향 (Effect of Yongdam Dam Operation to Level of Reference Flows Downstream)

  • 노재경;유재민;오진영
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.1772-1776
    • /
    • 2006
  • The Ministry of Environment is determining reference flows and goal water qualities in many stations over all around riverbasin to control TMDL. Reference flow is now defined to 10 years averaged 275th minimum flow$(Q_{275})$. Dam operation takes direct effect on flows downstream. The Yongdam mutipurposed dam was constructed in 2002 and TMDL managing stations between the Daecheong dam and the Yongdam dam are the Geumbon B, C, D, E, and F in main stream of the Geum river. Geumbon F is the Daecheong dam site. Observed flows are ideal to be used to set reference flows, but simulated flows are more practical to be used to set reference flows from the cause of the Yongdam dam's operation. A system for simulating daily storages of the Yongdam dam was constructed and the DAWAST model was selected to simulate daily streamflows. Analysis period was selected for 10 years from 1996 to 2005. Scenario was set as follows; Firstly, observed outflows from the Yongdam dam are used from 2002 to 2005 and the Yongdam dam does not exist from 1995 to 2001. Secondly, the Yongdam dam existed also from 1995 to 2001 and simulated outflows from the Yongdam dam are used from 1996 to 2005 with provision of constant outflow of $7.0m^3/s$ and water supply to the Jeonju region outsided watershed of $900,000m^3/day$. In case of scenario 1 reference flows at the Geumbon B, C, D, E, F are 4.52, 6.69, 7.96, 11.17, and $13.21m^3/s$, respectively. And in case of scenario 2 reference flows at the Geumbon B, C, D, E, F are 6.27, 8.48, 9.58, 12.73, and $15.12m^3/s$, respectively.

  • PDF

개량된 다채널 임피던스형 측정기에 의한 기포율의 측정 (Void Fraction Measurement by the Improved Multi-Channel Impedance Void Meter)

  • 송철화;정문기
    • 대한기계학회논문집B
    • /
    • 제20권1호
    • /
    • pp.384-398
    • /
    • 1996
  • An improved multi-channel Impedance Void Meter (IVM) is developed to measure an area-averaged void fraction. It consists of a main sensor, a reference sensor and a signal processor. The sensor was designed to be flush-mounted to the inner wall of the test section to avoid the flow disturbances. Guard electrodes are used to obtain evenly distributed electrical field in a measuring volume. A reference sensor is also installed to eliminate the drift in void signal caused by the changes in electrical properties of working fluid. The signal processor with three channels is specially designed so as to minimize the inherent error due to the phase difference between channels. As an example of applications, the mean and fluctuating components of void fraction are measured for bubbly and slug flow regime, and it is shown that IVM has good dynamic resolution which is required to investigate the structural developments of bubbly flow and the propagation of void waves in a flow channel.