• Title/Summary/Keyword: Reference Spectrum

Search Result 332, Processing Time 0.031 seconds

A Study on the Law of Non-performance of International Sales Contract under the Contract Law of The People's Republic of China (중국계약법(中國契約法)상 무역계약불이행(貿易契約不履行)관련 규정(規定)의 연구(硏究))

  • Ahn, Yeong-Tae
    • International Commerce and Information Review
    • /
    • v.8 no.1
    • /
    • pp.243-257
    • /
    • 2006
  • This study is to introduce the Chinese Contract Law against non-performance of the contract and to solve the wide range of problems involving to executing the trading contract. The parties' liability for the period of performance, the place of performance, the failure to deliver conforming goods together with it's nature of the lack of conformity, and the methods of compensation against damages and the force majeure clauses application. Those issues affect directly to commercial transactions in international business. The focus is more on the interrelationship of private individuals in its trade and on aiming to remove the legal obstacles from the Chinese Contract Law to freely flow of international trade. Reference may include foreign corrupt practices, Conventions on Contracts for the International Sale of Goods and Laws of England, France, and Japan. This study has brought the efforts of these issues in the full spectrum of performance and with concentrations on effectiveness to avoid the different viewpoints of the general principles of CISG and commercial practice founded pre-eminently. This study, in presenting the legal framework, will contribute to a better understanding of the purpose of rules of Chinese Contract -Law as they interact to the benefit of the parties involved in international trade transactions. The writer believes that a problem-oriented approach and the concentration as outlined above would offer a different perspective for law faculty teaching in this area and hope that this study can be sufficiently diverse to satisfy many of those views.

  • PDF

Experiments on Extraction of Non-Parametric Warping Functions for Speaker Normalization (화자 정규화를 위한 비정형 워핑함수 도출에 관한 실험)

  • Shin, Ok-Keun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.5
    • /
    • pp.255-261
    • /
    • 2005
  • In this paper. experiments are conducted to extract a set of non-Parametric warping functions to examine the characteristics of the warping among speakers' utterances. For this Purpose. we made use of MFCC and LP spectra of vowels in choosing reference spectrum of each vowel as well as representative spectra of each speaker. These spectra are compared by DTW to give the warping functions of each speaker. The set of warping functions are then defined by clustering the warping functions of all the speakers. Noting that male and female warping functions have shapes similar to Piecewise linear function and Power function respectively, a new hybrid set of warping functions is defined. The effectiveness of the extracted warping functions are evaluated by conducting phone level recognition experiments, and improvements in accuracy rate are observed in both warping functions.

An Approach for Identifying the Temperature of Inductance Motors by Estimating the Rotor Slot Harmonic Based on Model Predictive Control

  • Wang, Liguo;Jiang, Qingyue;Zhang, Chaoyu;Jin, Dongxin;Deng, Hui
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.695-703
    • /
    • 2017
  • In order to satisfy the urgent requirements for the overheating protection of induction motors, an approach that can be used to identify motor temperature has been proposed based on the rotor slots harmonic (RSH) in this paper. One method to accomplish this is to improve the calculation efficiency of the RSH by predicting the stator winding distribution harmonic order by analyzing the harmonics spectrum. Another approach is to increase the identification accuracy of the RSH by suppressing the influence of voltage flashes or current surges during temperature estimation based on model predictive control (MPC). First, an analytical expression of the stator inductance is extracted from a steady-state positive sequence motor equivalent circuit model developed from the rotor flux field orientation. Then a procedure that applies MPC for reducing the identification error of the rotor temperature caused by voltage sag or swell of the power system is given. Due to this work, the efficiency and accuracy of the RSH have been significantly improved and validated our experiments. This work can serves as a reference for the on-line temperature monitoring and overheating protection of an induction motor.

Analysis of Solar Simulator's Uncertainty Factor for Photovoltaic Module's I-V curve test (PV모듈의 I-V특성 시험을 위한 Solar Simulator의 측정불확도 요인 분석)

  • Kang, Gi-Hwan;Park, Chi-Hong;Kim, Kyung-Soo;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.5-7
    • /
    • 2006
  • In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was $124.44W{\pm}0.75W$ with 95% confidence level for 125W PV module.

  • PDF

Design and Optimization for the Windowless Target of the China Nuclear Waste Transmutation Reactor

  • Cheng, Desheng;Wang, Weihua;Yang, Shijun;Deng, Haifei;Wang, Rongfei;Wang, Binjun
    • Nuclear Engineering and Technology
    • /
    • v.48 no.2
    • /
    • pp.360-367
    • /
    • 2016
  • A windowless spallation target can provide a neutron source and maintain neutron chain reaction for a subcritical reactor, and is a key component of China's nuclear waste transmutation of coupling accelerator and subcritical reactor. The main issue of the windowless target design is to form a stable and controllable free surface that can ensure that energy spectrum distribution is acquired for the neutron physical design when the high energy proton beam beats the lead-bismuth eutectic in the spallation target area. In this study, morphology and flow characteristics of the free surface of the windowless target were analyzed through the volume of fluid model using computational fluid dynamics simulation, and the results show that the outlet cross section size of the target is the key to form a stable and controllable free surface, as well as the outlet with an arc transition. The optimization parameter of the target design, in which the radius of outlet cross section is $60{\pm}1mm$, is verified to form a stable and controllable free surface and to reduce the formation of air bubbles. This work can function as a reference for carrying out engineering design of windowless target and for verification experiments.

Application of Receiver Operating Characteristic (ROC) Curve for Evaluation of Diagnostic Test Performance (진단검사의 특성 평가를 위한 Receiver Operating Characteristic (ROC) 곡선의 활용)

  • Pak, Son-Il;Oh, Tae-Ho
    • Journal of Veterinary Clinics
    • /
    • v.33 no.2
    • /
    • pp.97-101
    • /
    • 2016
  • In the field of clinical medicine, diagnostic accuracy studies refer to the degree of agreement between the index test and the reference standard for the discriminatory ability to identify a target disorder of interest in a patient. The receiver operating characteristic (ROC) curve offers a graphical display the trade-off between sensitivity and specificity at each cutoff for a diagnostic test and is useful in assigning the best cutoff for clinical use. In this end, the ROC curve analysis is a useful tool for estimating and comparing the accuracy of competing diagnostic tests. This paper reviews briefly the measures of diagnostic accuracy such as sensitivity, specificity, and area under the ROC curve (AUC) that is a summary measure for diagnostic accuracy across the spectrum of test results. In addition, the methods of creating an ROC curve in single diagnostic test with five-category discrete scale for disease classification from healthy individuals, meaningful interpretation of the AUC, and the applications of ROC methodology in clinical medicine to determine the optimal cutoff values have been discussed using a hypothetical example as an illustration.

Particulate Distribution Map of Tidal Flat using Unsupervised Classification of Multi-Temporary Satellite Data (다중시기 위성영상의 무감독분류에 의한 갯벌의 입자 분포도)

  • 정종철
    • Korean Journal of Remote Sensing
    • /
    • v.18 no.2
    • /
    • pp.71-79
    • /
    • 2002
  • This research presents particulate distribution map of tidal flats of Hampyung bay using reflectance which extracted from satellite data and field survey data during same periods. The spectrum of particulate composition obtained from Landsat TM data was analysed and 7 scenes of satellite image were classified with ISODATA and K-MEANS methods. The results of unsupervised classification were estimated with in-situ data. The classification accuracy of ISODATA and K-MAMS methods were 84.3% and 85.7%. For validation of classified results of multi-temporal satellite images, TM image of May 1999(reference data), which was classified with field survey data was compared with classified results of multi-temporary satellite data.

Local Structure Refinement of the $BaFe_{1-x}Sn_xO_{3-y}$ System with Fe K-Edge X-Ray Absorption (XANES/EXAFS) Spectroscopy

  • 김민규;곽기섭;로권선;여철현
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.7
    • /
    • pp.743-749
    • /
    • 1997
  • Local structure refinement of the BaFe1-xSnxO3-y system (x=0.00-0.50) has been carried out with Fe K-edge x-ray absorpion spectroscopic studies. It is found out that the Fe ions are placed in two different symmetric sites such as tetrahedral and octahedral sites in the compounds by comparison with Fe K-edge x-ray absorption near edge structure (XANES) spectrum of the γ-Fe2O3 compound as a reference. Small absorption peaks of dipole-forbiden transitions appear at a pre-edge region of 7111 eV due to the existence of Fe ions in the tetrahedral and octahedral sites. The peak intensity decreases with the substitution amount of Sn ion. Three different absorption peaks of 1s→4p dipole-allowed transition appear on the energy region between 7123 and 7131 eV. The peaks correspond to 1s→4p main transition of Fe ions in tetrahedral and octahedral sites and 1s→4p transition followed by the shakedown process of ligand to metal charge transfer. The bond distances between Fe ions in the tetrahedral site and nearest neighboring oxygen atom (Fe-4O), and those in octahedral site (Fe-6O) are determined with the extended x-ray absorption fine structure (EXAFS) analysis. Two different interatomic distances increase with the substitution amount of Sn ion and also the bond lengths of Fe-4O are shorter than those of Fe-6O in all compounds.

Application of Laser Induced Photoacoustic Spectroscopy in the Investigation of Interaction of Neodymium(III) with Water Soluble Synthetic Polymer

  • Tae Hyung Yoon;Hichung Moon;Seung Min Park;Joong Gill Choi;Paul Joe Chong
    • Bulletin of the Korean Chemical Society
    • /
    • v.14 no.5
    • /
    • pp.574-578
    • /
    • 1993
  • Laser-induced photoacoustic spectroscopy (LIPAS), which utilizes the photothermal effect that results from nonradiative relaxation of excited state molecules, was used in the speciation analysis of the complexes of neodymium(III) and water soluble synthetic polyelectrolyte, poly methacrylic acid (PMAA), in 0.1 M $NaClO_4$ at pH of 6.0. The minimum detection limit of Nd(III) by LIPAS was $5.O{\times}10^{-6}$ M. Experiment was carried out at low concentration ratio of Nd(III) to PMAA to assure that 1 : 1 complexes predominate. The bound and free Nd(III) species were characterized by measuring nonradiative relaxation energy of the excited states $(^2GM{7/2}\;and\;^4G_{5/2})$ to the metastable state $(^4G_{3/2})$. Two species were quantified by deconvolution of the mixed spectrum using their respective reference spectra. The conditional stability constant measured by LIPAS was 5.52 L$mol^{-1}$.

Isomer Differentiation Using in silico MS2 Spectra. A Case Study for the CFM-ID Mass Spectrum Predictor

  • Milman, Boris L.;Ostrovidova, Ekaterina V.;Zhurkovich, Inna K.
    • Mass Spectrometry Letters
    • /
    • v.10 no.3
    • /
    • pp.93-101
    • /
    • 2019
  • Algorithms and software for predicting tandem mass spectra have been developed in recent years. In this work, we explore how distinct in silico $MS^2$ spectra are predicted for isomers, i.e. compounds having the same formula and similar molecular structures, to differentiate between them. We used the CFM-ID 2.0/3.0 predictor with regard to (a) test compounds, whose experimental mass spectra had been randomly sampled from the MassBank of North America (MoNA) collection, and to (b) the most widespread isomers of test compounds searched in the PubChem database. In the first validation test, in silico mass spectra constitute a reference library, and library searches are performed for test experimental spectra of "unknowns". The searches led to the true positive rate (TPR) of ($46-48{\pm}10$)%. In the second test, in silico and experimental spectra were interchanged and this resulted in a TPR of ($58{\pm}10$)%. There were no significant differences between results obtained with different metrics of spectral similarity and predictor versions. In a comparison of test compounds vs. their isomers, a statistically significant correlation between mass spectral data and structural features was observed. The TPR values obtained should be regarded as reasonable results for predicting tandem mass spectra of related chemical structures.