• Title/Summary/Keyword: Reference Rate

Search Result 1,957, Processing Time 0.025 seconds

Design of FM-QCSK Chaotic Communication System for high-speed communication (고속통신을 위한 FM-QCSK 카오스 통신 시스템)

  • Jang, Eun-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.10
    • /
    • pp.1183-1188
    • /
    • 2015
  • The FM-QCSK(: Frequency Modulated Quadrature Chaos Shift Keying) system is one of the most efficient systems in chaotic literature. One of the problems in this system is that half the bit duration is used for sending a chaotic reference signal which leads to increase the energy losses and reduces the data rate. In this paper, a novel scheme to enhance the performance of FM-QCSK system has been proposed. With the proposed scheme, FM-QCSK would be able to operate at higher data rates with reduced BER(: Bit Error Rate) and energy consumption. The basic modification introduced by the proposed scheme is the use one reference chaotic signal to transmit multi information signals in both in-phase and quadrature-phase channels. The results showed that the proposed scheme have achieved more than 3 dB gains in SNR for AWGN channels respectively at $BER=10^{-3}$ over the conventional one. The results also showed that the optimum number information signals can be send per reference signal is 8.

Assessing Health Impacts of Pictorial Health Warning Labels on Cigarette Packs in Korea Using DYNAMO-HIA

  • Kang, Eunjeong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.50 no.4
    • /
    • pp.251-261
    • /
    • 2017
  • Objectives: This study aimed to predict the 10-year impacts of the introduction of pictorial warning labels (PWLs) on cigarette packaging in 2016 in Korea for adults using DYNAMO-HIA. Methods: In total, four scenarios were constructed to better understand the potential health impacts of PWLs: two for PWLs and the other two for a hypothetical cigarette tax increase. In both policies, an optimistic and a conservative scenario were constructed. The reference scenario assumed the 2015 smoking rate would remain the same. Demographic data and epidemiological data were obtained from various sources. Differences in the predicted smoking prevalence and prevalence, incidence, and mortality from diseases were compared between the reference scenario and the four policy scenarios. Results: It was predicted that the optimistic PWLs scenario (PWO) would lower the smoking rate by 4.79% in males and 0.66% in females compared to the reference scenario in 2017. However, the impact on the reduction of the smoking rate was expected to diminish over time. PWO will prevent 85 238 cases of diabetes, 67 948 of chronic obstructive pulmonary disease, 31 526 of ischemic heart disease, 21 036 of lung cancer, and 3972 prevalent cases of oral cancer in total over the 10-year span due to the reductions in smoking prevalence. The impacts of PWO are expected to be between the impact of the optimistic and the conservative cigarette tax increase scenarios. The results were sensitive to the transition probability of smoking status. Conclusions: The introduction of PWLs in 2016 in Korea is expected reduce smoking prevalence and disease cases for the next 10 years, but regular replacements of PWLs are needed for persistent impacts.

CMAC Learning Controller Implementation With Multiple Sampling Rate: An Inverted Pendulum Example (다중 샘플링 타임을 갖는 CMAC 학습 제어기 실현: 역진자 제어)

  • Lee, Byoung-Soo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.4
    • /
    • pp.279-285
    • /
    • 2007
  • The objective of the research is two fold. The first is to design and propose a stable and robust learning control algorithm. The controller is CMAC Learning Controller which consists of a model-based controller, such as LQR or PID, as a reference control and a CMAC. The second objective is to implement a reference control and CMAC at two different sampling rates. Generally, a conventional controller is designed based on a mathematical plant model. However, increasing complexity of the plant and accuracy requirement on mathematical models nearly prohibits the application of the conventional controller design approach. To avoid inherent complexity and unavoidable uncertainty in modeling, biology mimetic methods have been developed. One of such attempts is Cerebellar Model Articulation Computer(CMAC) developed by Albus. CMAC has two main disadvantages. The first disadvantage of CMAC is increasing memory requirement with increasing number of input variables and with increasing accuracy demand. The memory needs can be solved with cheap memories due to recent development of new memory technology. The second disadvantage is a demand for processing powers which could be an obstacle especially when CMAC should be implemented in real-time. To overcome the disadvantages of CMAC, we propose CMAC learning controller with multiple sampling rates. With this approach a conventional controller which is a reference to CMAC at high enough sampling rate but CMAC runs at the processor's unoccupied time. To show efficiency of the proposed method, an inverted pendulum controller is designed and implemented. We also demonstrate it's possibility as an industrial control solution and robustness against a modeling uncertainty.

Dependent Quantization for Scalable Video Coding

  • Pranantha, Danu;Kim, Mun-Churl;Hahm, Sang-Jin;Lee, Keun-Sik;Park, Keun-Soo
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.127-132
    • /
    • 2006
  • Quantization in video coding plays an important role in controlling the bit-rate of compressed video bit-streams. It has been used as an important control means to adjust the amount of bit-streams to at]owed bandwidth of delivery networks and storage. Due to the dependent nature of video coding, dependent quantization has been proposed and applied for MPEG-2 video coding to better maintain the quality of reconstructed frame for given constraints of target bit-rate. Since Scalable Video Coding (SVC) being currently standardized exhibits highly dependent coding nature not only between frames but also lower and higher scalability layers where the dependent quantization can be effectively applied, in this paper, we propose a dependent quantization scheme for SVC and compare its performance in visual qualities and bit-rates with the current JSVM reference software for SVC. The proposed technique exploits the frame dependences within each GOP of SVC scalability layers to formulate dependent quantization. We utilize Lagrange optimization, which is widely accepted in R-D (rate-distortion) based optimization, and construct trellis graph to find the optimal cost path in the trellis by minimizing the R-D cost. The optimal cost path in the trellis graph is the optimal set of quantization parameters (QP) for frames within a GOP. In order to reduce the complexity, we employ pruning procedure using monotonicity property in the trellis optimization and cut the frame dependency into one GOP to decrease dependency depth. The optimal Lagrange multiplier that is used for SVC is equal to H.264/AVC which is also used in the mode prediction of the JSVM reference software. The experimental result shows that the dependent quantization outperforms the current JSVM reference software encoder which actually takes a linear increasing QP in temporal scalability layers. The superiority of the dependent quantization is achieved up to 1.25 dB increment in PSNR values and 20% bits saving for the enhancement layer of SVC.

  • PDF

Plan-Class Specific Reference Quality Assurance for Volumetric Modulated Arc Therapy

  • Rahman, Mohammad Mahfujur;Kim, Chan Hyeong;Kim, Seonghoon
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.1
    • /
    • pp.32-42
    • /
    • 2019
  • Background: There have been much efforts to develop the proper and realistic machine Quality Assurance (QA) reflecting on real Volumetric Modulated Arc Therapy (VMAT) plan. In this work we propose and test a special VMAT plan of plan-class specific (pcsr) QA, as a machine QA so that it might be a good solution to supplement weak point of present machine QA to make it more realistic for VMAT treatment. Materials and Methods: We divided human body into 5 treatment sites: brain, head and neck, chest, abdomen, and pelvis. One plan for each treatment site was selected from real VMAT cases and contours were mapped into the computational human phantom where the same plan as real VMAT plan was created and called plan-class specific reference (pcsr) QA plan. We delivered this pcsr QA plan on a daily basis over the full research period and tracked how much MLC movement and dosimetric error occurred in regular delivery. Several real patients under treatments were also tracked to test the usefulness of pcsr QA through comparisons between them. We used dynalog file viewer (DFV) and Dynalog file to analyze position and speed of individual MLC leaf. The gamma pass rate from portal dosimetry for different gamma criteria was analyzed to evaluate analyze dosimetric accuracy. Results and Discussion: The maxRMS of MLC position error for all plans were all within the tolerance limit of < 0.35 cm and the positional variation of maxPEs for both pcsr and real plans were observed very stable over the research session. Daily variations of maxRMS of MLC speed error and gamma pass rate for real VMAT plans were observed very comparable to those in their pcsr plans in good acceptable fluctuation. Conclusion: We believe that the newly proposed pcsr QA would be useful and helpful to predict the mid-term quality of real VMAT treatment delivery.

Comparison of the Ratio of Thicknesses of the Rhomboid Major and Middle Trapezius Muscles While Performing Scapular Retraction Exercises (어깨뼈 뒤 당김 운동 방법에 따른 큰마름근과 중간등세모근의 근두께비의 비교)

  • Park, Heon-mi;Kim, Suhn-yeop
    • Physical Therapy Korea
    • /
    • v.29 no.2
    • /
    • pp.131-139
    • /
    • 2022
  • Background: Shoulder impingement syndrome, a major cause of shoulder pain, involves weakness of the scapular retractor muscles. The major scapular retractor muscles are the middle trapezius and rhomboid major muscles; however, the latter is excluded in most studies. Objects: We aimed to measure the thickness of the middle trapezius and rhomboid major muscles using an ultrasonic diagnostic imaging system while performing four different shoulder retraction exercises and comparing the thicknesses and ratio of the thicknesses of these muscles. Methods: The thickness of the middle trapezius and rhomboid major muscles was measured in 24 healthy adults using ultrasound. Muscle thickness was measured three times in the Reference posture and four times while performing four different exercises that involved scapular retraction. The averages and standard deviations of the measured muscle thicknesses were obtained and compared. The ratio of muscle thickness and rate of changes in muscle thickness between the reference posture and the four exercises were compared. Results: For both, male (n = 10) and female (n = 14), there was a significant difference in the thickness of the middle trapezius muscle between the reference posture and the four exercises (p < 0.05) and in the thickness of the middle trapezius and rhomboid major muscles between male and female (p < 0.05); however, there was no significant difference in the ratio of the thicknesses of these muscles. Although a significant difference in the rate of change in muscle thickness during the four exercises was noted, there was no significant difference in the ratio of change in muscle thickness. Conclusion: This study demonstrates the ratio of the thicknesses of the middle trapezius and rhomboid major muscles and the rate of change in their thickness during exercises involving scapular retraction in healthy people in their 20s-30s.

A FLUOROSCOPIC STUDY ON THE STABILITY OF SKIN REFERENCE POINTS DURING JAW OPENING AND CLOSING MOVEMENT (방사선 투시를 이용한 개폐구 운동에 따른 수직 고경 계측점의 안정성에 관한 연구)

  • Ahn, Hyung-Jun;Kim, Chang-Whe;Kim, Yung-Soo;Kim, Yong-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.516-530
    • /
    • 1999
  • The current clinical technique for occlusal vertical dimension recording is based on marking the skin reference points on the patient's face and measuring between these points using caliper-like device. And it is difficult to achieve reliable measurements by this technique because of movable soft tissue. The purpose of this study is to reveal the stability of skin reference points by comparing the relative movement between extra-oral skin reference points and intra-oral reference points using X-ray fluoroscope. 10 test subjects were divided into 2 groups : Group I (natural dentition) and Group II (denture-wearer whose vertical dimension was lost) and Group III consists of identical test subjects to Group II with their upper denture removed and record base inserted. Attaching the 3 mm diameter steel ball to nose tip, lower lip, chin and to existing denture (or record base), fluoroscopic examination and recording were taken during 2 jaw opening and closing movements. After subsequent digitization using personal computer, 1219 still pictures with 0.1 second interval were made. Using the 2 dimensional graphic software, measurements between reference points were executed. Dividing the entire jaw movement into 3 ranges (total, 1st half opening, 2nd half opening), rate of movement and relative movement between extra-oral and intra-oral reference points were calculated and statistically analyzed. The results of this study are as follows. 1 Within the same experimental group, no statistical difference was found in the stability of skin reference between lower lip point and chin point during total range of jaw opening and closing movement (p>.05) 2. In the first half range of jaw opening, statistical difference was found between Group I (natural dentition) and Group II (denture wearer) (p<.05) Group I has greater skin reference stability than Group II. 3. In the first half range of jaw opening, statistical difference was found between Group I and Group III (record base wearer) (p<.05). Group I has greater skin reference stability than Group III. 4. In the first half range of jaw opening, no statistical difference was found in the stability of skin reference between Group II and Group III (p>.05). 5. In the second half range of jaw opening, no statistical difference was found in the stability of skin reference between any experimental groups (p>.05). 6. In patients with their occlusal vertical dimension lost, employing other measuring references rather than skin is recommended because of low stability.

  • PDF

Strategy for English Translations of Journal Reference (참고문헌 영문화 작업에 있어 영어번역의 전략)

  • Song, Ho-Sueb
    • Journal of Acupuncture Research
    • /
    • v.28 no.3
    • /
    • pp.121-129
    • /
    • 2011
  • Objectives : This study was to propose how to translate journal references into english for enhancing citation index of the journals published in the Korean Oriental Medical Society. Methods : Journal reference is mainly composed of author name, title or book name, journal name such as Index Medicus or publisher name, etc. In order to find the appropriate equivalents to the above major constituents, head words extracted from all the references of Journal of Korean Oriental Medical Society published in 2002 to 2009. A plan for English translation of the journal reference was formulated and the glossary was prepared. Plan for English translation of the journal reference : 1. Author: Author name was represented as capitalized last name and two initials of first name and listed up to six. If there are more, the first three or six authors were listed with 'et al'. 2. Terminology of traditional Korean medicine: Standard korean traditional medical terminology was one of the current representative dictionary with as much as 6040 headwords, which was needed to be translated into English in order to provide substantial equivalents available for English translation of journal reference. Therefor 4361 english equivalents were to be newly adopted except for 1679 overlapped with them in WHO-IST. Source oriented translation and target oriented translation were allowed to be appropriately selected depending on the condition. In addition, principle of English translation of acupoint,medicinal Herbs, Herbal formula and classical works were proposed. 3. Basically the names of journals should be set in italics and abbreviated according to the List of journals indexed for medline (formerly Index Medicus) published by the National Library of Medicine. however, abbreviation of korean oriental medical journals were not yet established. Thus establishment of tentative korean index medicus should be considered. Conclusions : For the enhancement of journal citation index of korean traditional medical journals, it was suggested that english translation of journal reference should be one of the alternatives enhancing citation rate.

An analysis of the Digital Reference Services of Teaching & Learning Aid Centers under the Metropolitan City and Provincial Offices of Education in Korea (국내 광역시.도 교육청 교수학습지원센터의 디지털참고봉사 제공과 이용 현황 분석)

  • Jung Jong-Kee
    • Journal of Korean Library and Information Science Society
    • /
    • v.37 no.3
    • /
    • pp.173-191
    • /
    • 2006
  • Examinations and analysis were done to understand the digital reference services of the Teaching & Learning Aid Centers under 16 metropolitan city and provincial offices of education. The data used were collected from July 3. 2006 to July 15. 2006 by the direct contacts on their main homepages and recording the question and answer transcripts. It was proven that 13 of the 16 Teaching & Learning Aid Centers have done the reference services. In this study, several characteristics-whether the digital reference service was done or not, interface access level, its title, its communication tool, reference question number, reference question style, answer rate, etc-were analyzed. Tips for the future development were provided on the basis of the inadequacies and other findings revealed through this study.

  • PDF

OS CFAR Computation Time Reduction Technique to Apply Radar System in Real Time (레이다 시스템 실시간 적용을 위한 OS CFAR 연산 시간 단축 방안)

  • Kong, Young-Joo;Woo, Seon-Keol;Park, Sungho;Shin, Seung-Yong;Jang, Youn Hui;Yang, Eunjung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.10
    • /
    • pp.791-798
    • /
    • 2018
  • The CFAR algorithm is mainly used for target detection in radar systems. In particular, OS CFAR is used in a non-uniform noise environment. However, it requires a large amount of computation, because it should sort reference cells in ascending order. This makes it difficult to apply the radar system in real time. In this paper, we describe how to reduce the computational burden of OS CFAR. We compared the power of the test cell and reference cell to determine only the presence or absence of target detection. The common reference cells overlapping in the reference cells of the three test cells are obtained. We first compare the test cell with the highest power value among the three test cells to the common reference cells. Next, we compare each test cell to general reference cells, excluding the common reference cells. The computation time is shortened by reducing the power comparison computation amounts.