• Title/Summary/Keyword: Reference Frequency

Search Result 1,636, Processing Time 0.04 seconds

Neutral-Point Voltage Ripple Reduction of High Frequency Injection Sensorless Control of IPMSM Fed by a Three-Level Inverter (3레벨 인버터로 구동되는 IPMSM의 고주파 주입 센서리스 운전에서 중성점 전압 리플 저감)

  • Cho, Dae-Hyun;Kim, Seok-Min;Lee, Kyo-Beum
    • Journal of IKEEE
    • /
    • v.24 no.3
    • /
    • pp.867-876
    • /
    • 2020
  • This paper proposes a neutral-point voltage ripple reduction of high frequency injection sensorless control of IPMSM fed by a three-level inverter. The high frequency voltage injection method has been successfully applied to sensorless control for IPMSM at low speed region. In the process of high frequency voltage injection sensorless control for IPMSM, the neutral-point voltage ripple is increased. It should be reduced because it distorts the output current and decreases a life time of DC-link capacitor. The proposed method in this paper reduces the neutral-point voltage ripple by compensating the reference voltage, and the compensation value is calculated simply with reference voltages and currents. The effectiveness of the proposed method is verified by simulation results.

The Implementation of Load Resistance Measurement System using Time-Frequency Domain Reflectometry (시간-주파수 영역 반사파 계측방법을 이용한 부하 저항 측정 시스템 구현)

  • Kwak, Ki-Seok;Park, Tae-Geun;Yoon, Tae-Sung;Park, Jin-Bae
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.10
    • /
    • pp.435-442
    • /
    • 2006
  • One of the most important topics about the safety of electrical and electronic system is the reliability of the wiring system. The Time-Frequency Domain Reflectometry(TFDR) is a state-of-the-art system for detecting and estimating of the fault on a wiring. In this paper, We've considered the load resistance measurement on a coaxial cable using TFDR in a way of expanded application. The TFDR system was built using commercial Pci extensions for Instrumentation(PXI) and LabVIEW. The proposed real time TFDR system consisted of the reference signal design, signal generation, signal acquisition, algorithm execution and results display part. To implement real time system, all of the parts were programmed by the LabVIEW which is one of the graphical programming languages. Using the application software implemented by the LabVIEW, we were able to design a proper reference signal which is suitable for target cable and control not only the arbitrary waveform generator in the signal generation part but alto the digital storage oscilloscope in the signal acquisition part. By using the TFDR real time system with the terminal resistor on the target cable, we carried out load impedance measurement experiments. The experimental results showed that the proposed system are able not only to detect the location of impedance discontinuity on the cable but also to estimate the load resistance with high accuracy.

Assessment of Magnetic Field Mitigation and Electrical Environmental Effects for Commercially Operating 154kV Transmission Lines with Passive Loop

  • Lee, Byeong-Yoon;Myung, Sung-Ho;Ju, Mun-No;Cho, Yeun-Gyu;Lee, Dong-Il;Lim, Yun-Seog;Kim, Sang-Beom
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.991-996
    • /
    • 2014
  • Power frequency magnetic field is still a critical problem for new construction of overhead power transmission lines in Korea because most people have been concerned about possibly carcinogenic effects of it. Although reference level of power frequency(60Hz) magnetic field has been set to 200uT in ICNIRP guidelines published in 2010, Korean government has no intention of adjusting 83.3uT specified by law in 2006 to this new reference level in consideration of people's concerns for the time being. Regardless of the current regulated magnetic field value, electric utility company has been trying to reduce magnetic field in the residential area in the vicinity of overhead power transmission lines to take into account of public concerns on the long-term effect of magnetic fields. In an effort to reduce magnetic field, engineering side has made considerable efforts to develop passive loop based, cost-effective mitigation technique of power frequency magnetic field more than ten years. In order to verify developed power frequency magnetic field mitigation technique based on passive loop, a horizontal type of passive loop was designed and installed for commercially operating 154kV overhead power transmission line for the first time in Korea. The measurement results before and after the installation of passive loop showed that magnetic field could be reduced to about 20%. The electrical environmental effects such as AN, RI and TVI were assessed before and after the installation of passive loop and these values were complied with the requirements specified by electric utility. It has been confirmed from the field test results that passive loop could be commercially and cost-effectively utilized to mitigate power frequency magnetic field.

Realtime Measurement of Impedance Locus using Impedance Spectroscopy: How Many and How Low Frequencies Are Required \ulcorner

  • T., Fukumoto;G. M., Eom;S., Ohba;N., Hoshimiya
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1194-1197
    • /
    • 2004
  • High temporal-resolution and accurate measurement of skin impedance locus provides useful data for the identification of the physiological/psychological changes and also the identification of acupuncture point. An impedance spectroscopy method using digitally constructed current waveform consisting of many frequency components (multiples of 1Hz) was reported3. The time resolution of the method depends on the lowest frequency used in the waveform construction, and therefore, the measurement would be faster if the lowest frequency is the higher. However, it was not clear that how many and how low frequencies must be used for the estimation of the skin impedance parameters from which the impedance locus can be drawn. This study shows the relationship between the estimation error of the impedance parameters and the frequency coverage of the spectroscopy. The results of this study are expected to serve as the reference of the frequency selection in the impedance spectroscopy.

  • PDF

A Voltage-to-frequency Converter Using BiCMOS Bandgap Reference Circuit (BiCMOS 기준 전압 회로를 이용한 전압-주파수 신호 변환회로)

  • 최진호
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.3
    • /
    • pp.105-108
    • /
    • 2003
  • In this work, a Voltage-to-Frequency Converter(VFC) in which the output frequency is proportional to the input voltage is proposed. To obtain the temperature stable characteristics of the VFC circuit is designed by BiCMOS technology. The output frequency range is 24KHz to 65KHz and the difference between simulated and calculated values is less than about 5% for this range of output frequency. The temperature variation of sample output frequencies is less than $\pm$0.5% in the temperature range $-25^{\circ}C$ to 75$^{\circ}C$.

Determination of Frequency Weighting Curves for the Evaluation of Steering Wheel Vibration (체감 진동량 평가를 위한 조향 휠 진동의 주파수 가중치 결정)

  • 홍석인;장한기;김승한
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.4
    • /
    • pp.165-172
    • /
    • 2003
  • This study aims to find frequency weighting curves for the evaluation of drivers' discomfort by vertical and rotational steering wheel vibration. Equal sensation curves, inverse of frequency weighting curves, were determined for the two kinds of vibrations respectively by using the sinusoidal signals with reference amplitudes from 0.2 to 0.4 m/s2 in the frequency range from 5 to 100 ㎐. Twelve subjects joined at the tests, and median values of the twelve judgments were used to determine the equal sensation curves. An experiment was followed to compare the relative sensation magnitude between the two kinds of equal sensation curves, which showed discomfort by the rotational vibration was 1.5 times of that by the vertical vibration at 50 ㎐.

Stable Haptic Interaction with Reference Energy Following Scheme (에너지 추종방법을 이용한 안정적 햅틱 상호작용)

  • Ryu Jee-Hwan
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.3
    • /
    • pp.277-283
    • /
    • 2006
  • A recently proposed method for stabilizing haptic interfaces and teleoperation systems was tested with a 'PHANToM' commercial haptic device. The 'Passivity Observer' (PO) and 'Passivity Control1er' (PC) stabilization method was applied to stabilize the system but also excited a high frequency mode in the device. To solve this problem, we propose a method to use a timevarying desired energy threshold instead of fixed zero energy threshold for the PO, and make the actual energy input follow the timevarying energy threshold. With the time-varying energy threshold, we make the PC control action smooth without sudden impulsive behavior by distributing the dissipation. The proposed new PO/PC approach is applied to PHANToM with high stiffness (K = 5000N/m), and stable and smooth contact is guaranteed. Resetting and active environment display problems also can be solved with the reference energy following idea.

Measurements of the In-Plane Vibration Intensity of a Beam Using an Reference Accelerometer (기준 가속도계를 이용한 보의 면내 진동인텐시티 측정)

  • Kim, C.R.;Kil, H.G.;Jeon, J.S.;Hong, S.Y.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.848-851
    • /
    • 2002
  • In this paper, an experimental method using a reference accelerometer has been developed to measure the in-plane vibration intensity of a beam. It has the advantages of reducing accelerometer phase error comparing with the cross spectral intensity measurement technique using an accelerometer array. It needs no measurement of the input force required in the frequency response method using the only one accelerometer This method has been used to measure the in-plane vibration intensity over the beam. The result has been compared with an input power and the vibration intensity obtained with other methods. It showed that the present experimental method can be effectively used to measure the structural in-plane vibration intensity.

  • PDF

The Effecting Variables on Fashion Jewelry Consumers' Purchasing Behavior - Materialism, Brand Royalty & Reference Group - (패션 주얼리 소비자(消費者)들의 구매행동(購買行動)에 미치는 영향(影響) 요인(影響) - 물질주의(物質主義), 상표충성도(商標忠誠倒), 준거집단(準據集團)을 중심(中心)으로 -)

  • Lee, Seung-Hee
    • Journal of Fashion Business
    • /
    • v.9 no.1
    • /
    • pp.152-159
    • /
    • 2005
  • The purpose of this study was to examine variables which influenced on fashion jewelry consumers' purchasing behavior. 565 respondents living in Seoul and its suburb were surveyed for this study. For data analysis, descriptive statistics, factor analysis, ANOVA, and regression were used for this study. As the result, the frequencies of purchasing toward the fashion jewelry products were associated with materialism, brand royalty, reference group influence. Also, results revealed that materialism and brand royalty accounted for 41% of the explained variance in the frequency of purchasing products on fashion jewelry. Based on these results, fashion jewelry marketing strategies would be suggested.

Harmonic Current Reference Generation of Single-Phase Active Filter for the Converter-Fed Locomotives (고속전철용 단상능동필터의 기준고조파전류 발생 방법)

  • Sung, Gi-Seok;Song, Joong-Ho;Choi, Ik;Choi, Ju-Yeop;Kim, Gwang-Bae;Kim, Kwon-Ho;Lim, Myo-Taek
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.338-341
    • /
    • 1999
  • PWM controlled line-side converters of modern ac traction locomotives inject harmonic currents into the feeding overhead line. This causes problem of electromagnetic interference. Passive and Active filters are usually provided for a reduction of the line harmonics. Active filters are more reasonable than passive filters in terms of weight and space of the filters. Successful control of active filters requires an accurate harmonic current reference. A technique to generate the harmonic current reference is proposed in this paper. The analysis is performed in frequency domain and its effectiveness is verified by simulation.

  • PDF