• Title/Summary/Keyword: Reference Frequency

Search Result 1,628, Processing Time 0.028 seconds

Statistical reference values for control performance assessment of seismic shake table testing

  • Chen, Pei-Ching;Kek, Meng-Kwee;Hu, Yu-Wei;Lai, Chin-Ta
    • Earthquakes and Structures
    • /
    • v.15 no.6
    • /
    • pp.595-603
    • /
    • 2018
  • Shake table testing has been regarded as one of the most effective experimental approaches to evaluate seismic response of structural systems subjected to earthquakes. However, reproducing a prescribed acceleration time history precisely over the frequency of interest is challenging because shake table test systems are eventually nonlinear by nature. In addition, interaction between the table and specimen could affect the control accuracy of shake table testing significantly. Various novel control algorithms have been proposed to improve the control accuracy of shake table testing; however, reference values for control performance assessment remain rare. In this study, reference values for control performance assessment of shake table testing are specified based on the statistical analyses of 1,209 experimental data provided by the Seismic Simulator Laboratory of National Center for Research on Earthquake Engineering in Taiwan. Three individual reference values are considered for the assessment including the root-mean-square error of the achieved acceleration time history; the percentage of the spectral acceleration that exceeds the determined tolerance range over the frequency of interest; and the error-ratio of the achieved peak ground acceleration. Quartiles of the real experimental data in terms of the three objective variables are obtained, providing users with solid and simple references to evaluate the control performance of shake table testing. Finally, a set of experimental data of a newly developed control framework implementation for uni-axial shake tables are used as an application example to demonstrate the significant improvement of control accuracy according to the reference values provided in this study.

Design of Fractional-N Frequency Synthesizer with Delta-Sigma Modulator for Wireless Mobile Communications (Delta-Sigma Modulator를 이용한 무선이동통신용 Fractional-N 주파수합성기 설계)

  • Park, Byung-Ha
    • Journal of IKEEE
    • /
    • v.3 no.1 s.4
    • /
    • pp.39-49
    • /
    • 1999
  • This paper describes a 1 GHz, low-phase-noise CMOS fractional-N frequency synthesizer with an integrated LC VCO. The proposed frequency synthesizer, which uses a high-order delta-sigma modulator to suppress the fractional spurious tones at all multiples of the fractional frequency resolution offset, has 64 programmable frequency channels with frequency resolution of $f_ref/64$. The measured phase noise is as low as -110 dBc/Hz at a 200 KHz offset frequency from a carrier frequency of 980 MHz. The reference sideband spurs are -73.5 dBc. The prototype is implemented in a $0.5{\mu}m$ CMOS process with triple metal layers. The active chip area is about $4mm^2$ and the prototype consumes 43 mW, including the VCO buffer power consumption, from a 3.3 V supply voltage.

  • PDF

Single-phase Active Power Filter Based on Rotating Reference Frame Method for Harmonics Compensation

  • Kim, Jin-Sun;Kim, Young-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.94-100
    • /
    • 2008
  • This paper presents a new control method of single-phase active power filter (APF) for the compensation of harmonic current components in nonlinear loads. To facilitate the possibility of complex calculation for harmonic current detection of the single phase, a single-phase system that has two phases was constructed by including an imaginary second-phase giving time delay to the load current. The imaginary phase, which lagged the load current T/4 (Here T is the fundamental cycle) is used in the conventional method. But in this proposed method, the new signal as the second phase is delayed by the filter. Because this control method is applied to a single-phase system, an instantaneous calculation was developed by using the rotating reference frames synchronized to source-frequency rather than by applying instantaneous reactive power theory that uses the conventional fixed reference frames. The control scheme of single-phase APF for the current source with R-L loads is applied to a laboratory prototype to verify the proposed control method.

Very-Far Remote Reference Magnetotelluric Surveys across the Hemispheres

  • Lee, Tae-Jong;Lee, Seong-Kon;Song, Yoon-Ho;Cull, James
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.273-278
    • /
    • 2007
  • 2-D MT surveys at the Century mine in Australia have been performed with very far remote reference in Esashi, Japan as well as Gregory Downs, which are roughly 6400 km and 80 km apart from the field site, respectively. Long period pulsations observed in this survey generally showed dominant $H_x$ polarization than $H_y$; $H_x$ component is more than 3 times stronger than $H_y$ component. Polarity reversal in magnetic field pointing east ($H_y$ component) has also been observed in long period pulsations, while $H_x$ component remain coherent between the hemispheres. Though $H_x$ component shows relatively good coherency than $H_y$ component between the hemispheres at frequencies lower than 0.01 Hz, it seems rather too far to be used as a remote reference for ordinary MT frequency band.

  • PDF

Measurement and Analysis of the Korean NDGPS Radiation Spectrum

  • Kim, Young-Wan;Jee, Suk-Kun
    • Journal of information and communication convergence engineering
    • /
    • v.10 no.3
    • /
    • pp.225-230
    • /
    • 2012
  • The Korean nationwide differential global positioning system (NDGPS) reference station transmits a global positioning system (GPS) enhancement signal using minimum shift keying modulation with a 200 bps data rate. The ocean-based DGPS covers the service area of 100 NM with 300 W output power; on the other hand, the land-based DGPS transmits the output power of 500 W, which covers the service area of 100 km. The DGPS reference stations with high output power can radiate spurious signals, which may act as interference sources affecting the other DGPS reference stations or the wireless ground stations that utilize the medium frequency band. In this paper, the radiation spectrums of the DGPS reference stations are measured and analyzed in the spurious domain. The DGPS radiation spectrums are evaluated from the perspective of the interference effect.

Workpiece Horizontality and Reference Positioning of Cutting Tool by Measuring Impedance in Ultra-Precision-Machining (초정밀가공 시 임피던스 측정을 통한 시편 수평맞춤 및 공구의 기준위치 설정)

  • Lee, Ho-Cheol;Kim, Gi-Dae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.12
    • /
    • pp.1366-1371
    • /
    • 2011
  • In ultra precision machining, it is necessary to adjust the horizontality and reference position of a workpiece in a noncontact manner. For this, a simple process by measuring impedance between a tool tip and a workpiece which are connected to impedance analyzer is proposed. As the distance between the tool and the workpiece gets closer, the reduction rate of impedance becomes higher over all frequency ranges. By setting threshold value of impedance reduction rate at specific frequencies through preliminary experiments, the distance between the tool and the workpiece can be predicted and it directly enables us to horizontalize the workpiece and to set the tool to the desired reference position.

A Temperature Stable PWM Controller Using Bandgap Reference Voltage (밴드갭 기준전압을 이용한 동작온도에 무관한 PWM 컨트롤러)

  • Choi, Jin-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.8
    • /
    • pp.1552-1557
    • /
    • 2007
  • In this work, temperature stable pulse width modulation controller using bandgap reference voltage is proposed. Two bandgap reference voltages are designed by using BiCMOS technology which are temperature dependent and independent voltage references. PWM controller is designed by using 3.3 volt supply voltage and the output frequency is 1MHz. From simulation results, the variation of output pulse width is less than form +0.86% to -0.38% in the temperature range $0^{\circ}C\;to\;70^{\circ}C$.

DQ Synchronous Reference Frame Model of a Series-Parallel Tuned Inductive Power Transfer System (직렬-병렬 공진 무선전력전송 시스템의 동기 좌표계 모델)

  • Noh, Eun-Chong;Lee, Sang-Min;Lee, Seung-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.6
    • /
    • pp.477-483
    • /
    • 2020
  • This study proposes a DQ synchronous reference frame model of a series-parallel tuned inductive power transfer (SP-IPT) system. The wireless power transmission system experiences control difficulty because the transmitter-side controller cannot directly measure the receiver-side load voltages and currents. Therefore, a control-oriented circuit model that shows the dynamics of the IPT system is required to achieve a well-behaved controller. In this study, an equivalent circuit model of the SP-IPT system in a synchronously rotating reference frame is proposed using the single-phase DQ transformation technique. The proposed circuit model is helpful in modeling the dynamics of the voltages and currents of the transmitter- and receiver-side resonant tanks and loads. The proposed circuit model is evaluated using frequency- and time-domain simulation results.

A synchronization algorithm for OFDM signals (OFDM 신호의 동기 알고리듬)

  • 허영식;김기호김용훈
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.187-190
    • /
    • 1998
  • In this paper, a synchronization method of OFDM signals are introduced and its performance is estimated. A proposed method can perform a frame/symbol timing, carrier frequency synchronizations. Reference symbols consist of two duplicate OFDM symbols carrying signals on every sub-carriers. Performances of synchronization under 60GHz millimeter-wave indoor channels are evaluated, which were measured with frequency-sweeping method in common office buildings. A proposed method has improved performances owing to long averaging durations of synchronization metrics in frame/symbol timing, carrier frequency synchronization procedures.

  • PDF

Discussion of Exposure Evaluation Associated with Extremely Low Frequency-magnetic Field in the Case of Portable Hand-held Fans (휴대용 손 선풍기의 극저주파 자기장 발생 수준 평가와 쟁점 고찰)

  • Park, Dong-Uk;Yi, Seongjin;Kim, So-Youn;Bae, Seo-Youn;Choi, Sangjun;Kim, Won;Min, Sung Hyon;Park, Jihoon;Ahn, Jongju
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.5
    • /
    • pp.480-490
    • /
    • 2018
  • Objective: This study aimed to report the level of extremely low frequency-magnetic field (ELF-MF) emitted by portable hand-held fans (HHF) and to discuss the methodologies for determining the health risk of ELF-MF for HHF products. Method: ELF-MF was monitored at eight locations by distances in the vicinity of HHFs. A total of 13 HHF brands on the market were randomly selected. A portable ELF-MF monitor MDEX II was used to measure the ELF-MF level in the range of 40-800 Hz with a resolution of $0.01{\mu}T$. This study also examined the frequency results of a total of 45 HHF products investigated by the Korean Ministry of Science and ICT (KMSICT). Results: ELF-MF higher than $0.3{\mu}T$ was found to be emitted at a distance of less than 20 cm from 12 HHF. ELF-MF emitted from four products was found to exceed the reference level ($83.3{\mu}T$ based on 60 Hz) recommended by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). KMSIT reported that the principle frequency emitted from the HHFs ranged from 54 Hz to 284 kHz, without the level of LEF-MF. Unscientifically, the KMSICT used the reference level by ICNIRP as the chronic level and concluded that all HHFs are safe with a basis of 1.2-36.0% less than the reference level. Conclusion: The HHF emitted much higher levels of ELF-MF than $0.3-0.4{\mu}T$, which is regarded as the reference level for childhood leukemia. The risk of HHF should be examined in terms of whether they can be used by the general public, including children and pregnant woman.