• 제목/요약/키워드: Reference Flow

검색결과 795건 처리시간 0.143초

Study on Methanol Conversion Efficiency and Mass Transfer of Steam-Methanol Reforming on Flow Rate Variation in Curved Channel (곡유로 채널을 가지는 수증기-메탄올 개질기에서 유량 변화에 따른 메탄올 전환율 및 물질 전달에 관한 연구)

  • Jang, Hyun;Park, In Sung;Suh, Jeong Se
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제39권3호
    • /
    • pp.261-269
    • /
    • 2015
  • In this study, numerical analysis of curved channel steam-methanol reformer was conducted using the computational fluid dynamics (CFD) commercial code STAR-CCM. A pre-numerical analysis of reference model with a cylindrical channel reactor was performed to validate the combustion model of the CFD commercial code. The result of advance validation was in agreement with reference model over 95%. After completing the validation, a curved channel reactor was designed to determine the effects of shape and length of flow path on methanol conversion efficiency and generation of hydrogen. Numerical analysis of the curved-channel reformer was conducted under various flow rate ($10/15/20{\mu}l/min$). As a result, the characteristics of flow and mass transfer were confirmed in the cylindrical channel and curved channel reactor, and useful information about methanol conversion efficiency and hydrogen generation was obtained for various flow rate.

Suggestion of the Analysis Model and Verification on Rotating Flow in Stirred Tanks Using CFD (전산유체역학을 이용한 교반 탱크 내에서의 회전유동에 대한 해석 모델의 제안 및 검증)

  • Hwang, Seung Sik;Yong, Cho Hwan;Choi, Gyuhong;Shin, Dohghoon;Chung, Tae Yong
    • Journal of Energy Engineering
    • /
    • 제22권1호
    • /
    • pp.28-37
    • /
    • 2013
  • Stirred tank is widely used in various industries for mixing operations and chemical reactions for single- or multi-phase fluid systems. For designing agitator of high performance, quantity data of internal flow characteristics influenced by mixing performance are definitely confirmed but quantity analysis about the transient flow characteristics of complicate structure is recognized as difficult problem in the present. In this study, two models of commercial CFD code Fluent 6.3 used to propose suitable for the tank analysis. Agitation of Stirred tank is analyzed using a mixed model and the flow in the stirred tank is analyzed using a standard k-${\varepsilon}$ model. Multiple reference frame(MRF) and Sliding mesh(SM), the analysis techniques were used For compare a result of CFD with a visualization experiment result, to grasp internal flow and mixing characteristic in stirred tank and to present fundamental analysis method.

Finite Element Analysis for Wavelike Flow Marks in Injection Molding

  • Kang, Sung-Yong;Lee, Woo-Il
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 한국소성가공학회 2003년도 The Korea-Japan Plastics Processing Joint Seminar
    • /
    • pp.27-32
    • /
    • 2003
  • The wavelike flow mark phenomenon is one of the surface defects that can arise during the injection stage of the injection molding process. We have performed a numerical analysis using a finite element method for the injection molding to verify the validity of 'Go-over' hypothesis. Also, we have compared the results of numerical analysis with available experimental data. Numerical analysis results of the flow marks are qualitatively in good agreement with experimental data of reference, but are quantitatively deviated from experimental data in a consistent manner. A parametric study has been performed to examine the correlative effects of various injection molding processing parameters and material properties on the flow mark size.

  • PDF

A study on Development of Korean - Energy System Management Model for Effect Analysis of Integrated Demand Management (통합수요관리 효과분석을 위한 한국형 Energy System Management 모형 개발에 관한 연구)

  • Kim, Yong-Ha;Jo, Hyun-Mi;Kim, Ui-Gyeong;Yoo, Jeong-Hui;Kim, Dong-Gun;Woo, Sung-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제60권6호
    • /
    • pp.1103-1111
    • /
    • 2011
  • This paper is developed to Energy Balance Flow show the flow of total energy resource be used nationally. The Energy Balance Flow is applicable of demand management factor through the analysis of foreign energy model of supply and demand and energy statistic data in the country. This study is based on and developed to Energy system management model is able to appraisal efficient of energy cost cutting, CO2 emission reduction and Energy saving at the national level calculated effect reached amount of primary energy to change of energy flow followed application of demand side management factor is able to appraisal quantitatively at the total energy to model of demand and supply.

Numerical study of three-dimensional flow through turbine flow meter (터빈유량계의 3차원 유동에 관한 수치적 연구)

  • Kim, J. B.;Park, K. A.;Ko, S.
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.247-252
    • /
    • 2000
  • Flow through turbine flow meter is simulated by solving the incompressible Navier-Stockes equations. The solution method is based on the pseudocompressibility approach and uses an implicit-upwind differencing scheme together with the Gauss-Seidel Line relaxation method. The equations are solved steadily in rotating reference frames and the centrifugal force and the Coriolis force are added to the equation of motion. The standard k-$\epsilon$ model is employed to evaluate turbulent viscosity.

  • PDF

Optimization of Vane Diffuser in a Mixed-Flow Pump for High Efficiency Design

  • Kim, Jin-Hyuk;Kim, Kwang-Yong
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권1호
    • /
    • pp.172-178
    • /
    • 2011
  • This paper presents an optimization procedure for high-efficiency design of a mixed-flow pump. Optimization techniques based on a weighted-average surrogate model are used to optimize a vane diffuser of a mixed-flow pump. Validation of the numerical results is performed through experimental data for head, power and efficiency. Three-level full factorial design is used to generate nine design points within the design space. Three-dimensional Reynoldsaveraged Navier-Stokes equations with the shear stress transport turbulence model are discretized by using finite volume approximation and solved on hexahedral grids to evaluate the efficiency as the objective function. In order to reduce pressure loss in the vane diffuser, two variables defining the straight vane length ratio and the diffusion area ratio are selected as design variables in the present optimization. As the results of the design optimization, the efficiency at the design flow coefficient is improved by 7.05% and the off-design efficiencies are also improved in comparison with the reference design.

Optimization of Shroud Shape and Fan Location for Increasing Exhaust Flow Rate of Air Conditioner Outdoor Unit (실외기 토출 유량 증대를 위한 Shroud 형상 및 휀 위치 최적 설계)

  • Ryu, Ki-Jung;Kim, Yoo-Yil;Lee, Kwan-Soo;Cha, Woo-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제21권11호
    • /
    • pp.599-605
    • /
    • 2009
  • This paper presents a numerical evaluation of the flow rate of air conditioner outdoor unit by investigating the effects of fan location and shroud shape. To determine optimal design parameters, we investigated the exhaust flow rate by changing shroud height, fan height, fan guide height, and fan width. The 3rd order central composite design was performed to select three most important parameters affecting the exhaust flow rate. According to the result of response surface method, the exhaust flow rate of the optimum model increased by 6.25% compared to that of the base model.

The Effects of Pressure and Specific Heat on the Performance of Thermal Mass Flowmeter (열량형 질량유량계에 대한 압력과 비열 영향)

  • Choi, Y. M,;Park, K. A.;Choi, H. M.;Lee, K. S.
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.109-113
    • /
    • 1999
  • Thermal mass flow meter (TMF) is used measuring the small mass flow rate of gases. Generally, flow rate measuring accuracy of TMF is $\pm2{\%}$ of full scale. TMF is manufactured for specified working pressure and specified working gas by customer. If it were applied for different working pressure and gases, flow rate measurement accuracy decreased dramatically. In this study, a TMF tested with three different gases and pressure range of 0.2 MPa to 1.0 MPa. Effect of specific heat cause to increase flow measurement error as much as ratio of specific heat compare with reference gas. Pressure change cause to increase flowrate measurement deviation about $-0.2{\%}$ as the working pressure decreased 0.1 MPa.

  • PDF

Characteristics of $\beta$-glucosidase Immobilized on the Diazotized Chitin in Bioreactors (Diazotized Chitin에 고정된 $\beta$-glucosidase의 생물 반응기에서의 동특성)

  • 김종덕;이경희송승구
    • KSBB Journal
    • /
    • 제6권2호
    • /
    • pp.147-156
    • /
    • 1991
  • Diazotized chitin (CHITN) was synthesized reacting with NaN3 and HCl to alkaline hydrolyzed chitin for the support of immobilized enzyme. Immobilized $\beta$-glucosidase on diazotized chitin(CHITN-Gase) was produced reacting with glutaraldehyds as bifunctional reagent. CHITN-Gase activities were determined reacting with p-nitrophenol-$\beta$-D-glucopyranoside in plug flow reactor as a reference. Optimum temperature, optimum pH, reaction constant and deactivation rate were determined with variation of flow rate and H/D. The particle size of immobilized enzyme in the best was, 35 mesh (CHITN35-Gase). The optimum conditions of immobilized enzyme were $70^{\circ}C$ in temperature and 5.0 in pH. Diameter and flow rate of plug flow reactor in the best was 8.5mm in diameter and 0.8ml/min in flow rate. Reaction constant was mainly influenced by electrostatic force. The best glucose hydrolizing activities of CHITN3 5-Gase was 3.34$\times$10-5 M/1. while that of native-$\beta$-glucosidase was 2.44$\times$10-5 M/1.

  • PDF

Finite Element Analysis for Wave-like Flow Marks in Injection Molding (사출성형 공정 중 물결 무늬에 대한 유한요소 해석)

  • S. Y Kang;Lee, W. I.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 한국소성가공학회 2003년도 춘계학술대회논문집
    • /
    • pp.474-480
    • /
    • 2003
  • The wavelike flow mark phenomenon is one of the surface defects that can arise during the injection stage of the injection molding process. We have performed a numerical analysis using a finite element method for the injection molding to verify the validity of “Go-over” hypothesis. Also, we have compared the results of numerical analysis with available experimental data. Numerical analysis results of the flow marks are qualitatively in good agreement with experimental data of reference, but are quantitatively deviated from experimental data in a consistent manner. A parametric study has been performed to examine the correlative effects of various injection molding processing parameters and material properties on the flow mark size.

  • PDF