• 제목/요약/키워드: Reference Artifact

검색결과 46건 처리시간 0.025초

기준물을 이용한 NC 공작기계의 오차규명 및 보상제어 (Error Identification and Compensation for NC Machine Tools Using the Reference Artifact)

  • 정성종
    • 한국생산제조학회지
    • /
    • 제9권2호
    • /
    • pp.102-111
    • /
    • 2000
  • Methodology of volumetric error identification and compensation is presented to improve the accuracy of NC machine tools by using a reference artifact and a touch trigger probe. Homogeneous transformation matrix and kinematic chain are used for modeling the geo-metric and thermal errors of a three-axis vertical machining center. The reference artifact is designed and fabricated to identify the model parameters by machine tool metrology. Parameters in the error model are able to be identified and updated by direct measurement of the reference artifact on the machine tool under the actual conditions which include the thermal interactions of error sources. A volumetric error compensation system based on IBM/PC is linked with a FANUC CNC controller to compensate for the identified volumetric error in machining workspace.

  • PDF

기준물을 이용한 NC 공작기계의 체적오차 규명 (Volumetric Error Identification for NC Machine Tools Using the Reference Artifact)

  • 김경돈;정성종
    • 대한기계학회논문집A
    • /
    • 제24권12호
    • /
    • pp.2899-2908
    • /
    • 2000
  • Methodology of volumetric error identification is presented to improve the accuracy of NC machine tools by using a reference artifact and a touch trigger probe. Homogeneous transformation matrix and kinematic chain are used for modeling the geometric and thermal errors of a three-axis vertical machining center. The reference artifact is designed and fabricated to identify the model parameters by machine tool metrology. Parameters in the error model are able to be identified and updated by direct measurement of the reference artifact on the machine tool under the actual conditions which include the thermal interactions of error sources. The proposed method can speed up and simplify volumetric error identification processes.

기준물을 이용한 공작기계 위치오차 보정기술에 관한 연구 (A Study on the Error Compensation of Machine Tool Position Using Reference Artifact and On-machine probe)

  • 조남규;박재준;정성종
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 추계학술대회논문집 - 한국공작기계학회
    • /
    • pp.20-25
    • /
    • 2000
  • In this paper, a methodology of geometrical error identification and compensation for NC machine tool position. We have proposed a reference artifact with which, in measuring the coordinate system of NC machine, the robust coordinate systems are given. The coordinate system of the NC machine could be compensated successfully with the information obtained by measuring the reference artifact and our compensation algorithm. Monte Carlo simulation is used to evaluate coordinate referencing ability and, the uncertainties of the machine tool position is estimated and observed through the compensation process by simulation.

  • PDF

기준물을 이용한 공작기계 위치오차 보정기술에 관한 연구 (A Study on the Error Compensation of Machine Tool Position Using Reference Artifact and On-Machine Probe)

  • 조남규;박재준;정성종
    • 대한기계학회논문집A
    • /
    • 제25권9호
    • /
    • pp.1317-1324
    • /
    • 2001
  • In this paper, a methodology of geometrical error identification and compensation for NC machine tool position is developed. We propose a reference artifact with measuring the geometry of coordinate system for compensating linear scale error of NC machine. The coordinate system of the NC machine could be compensated successfully with the information obtained by measuring the reference artifact and our compensation algorithm. Monte Carlo simulation is used to evaluate coordinate referencing ability and, the uncertainties of the machine tool position is estimated and observed through the compensation process by simulation.

Sprague Dawley Rat의 미세병변에서 Moire Artifact를 제거하기 위한 Grid suppression software 사용 후 영상분석 (Image Analysis Using Grid Suppression Software to Remove Moire Artifact from Micro Lesions of Sprague Dawley Rat)

  • 이상호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권4호
    • /
    • pp.575-580
    • /
    • 2017
  • Moire artifact는 미세병변과 주파수 대역이 중첩되기 때문에 moire artifact를 제거하는 Image processing software를 사용할 경우 미세 병변의 손실을 가져올 수 있다. 본 연구에서는 SD(Sprague Dawley) Rat에 microcalcification과 microfracture와 같은 미세병변을 임의로 형성하여 영상화하고, reference 영상과 grid suppression software를 사용한 영상, optimizied grid 영상을 비교 분석하였다. 영상은 두 명의 영상의학과 전문의가 컨소시엄을 형성하여 판독하였고, 판독 결과 값은 McNemar's test 이용하여 평가하였다. 73개의 microcalcifications 중 Grid suppression후 13 cases에서, optimized grid를 사용한 영상은 3 cases에서 영상의 손실이 확인되어 Grid suppression후의 영상이 통계적으로 유의하게 영상 손실을 발생하고 있음을 보여주고 있다(p=0.021). 총 53개의 fracture line은 Grid suppression을 시행한 후 영상에서 19 cases가 영상의 손실을 보였고, optimized grid를 사용한 영상에서는 영상손실이 없는 것으로 판독되었다. 따라서 미세병변을 진단하는 영상에 있어 moire artifact를 제거하기 위한 grid suppression software 사용은 신중하게 고려되어야 할 것이다.

Compression Artifact Reduction for 360-degree Images using Reference-based Deformable Convolutional Neural Network

  • Kim, Hee-Jae;Kang, Je-Won;Lee, Byung-Uk
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송∙미디어공학회 2021년도 추계학술대회
    • /
    • pp.41-44
    • /
    • 2021
  • In this paper, we propose an efficient reference-based compression artifact reduction network for 360-degree images in an equi-rectangular projection (ERP) domain. In our insight, conventional image restoration methods cannot be applied straightforwardly to 360-degree images due to the spherical distortion. To address this problem, we propose an adaptive disparity estimator using a deformable convolution to exploit correlation among 360-degree images. With the help of the proposed convolution, the disparity estimator establishes the spatial correspondence successfully between the ERPs and extract matched textures to be used for image restoration. The experimental results demonstrate that the proposed algorithm provides reliable high-quality textures from the reference and improves the quality of the restored image as compared to the state-of-the-art single image restoration methods.

  • PDF

영상 유도 방사선치료 시 Fiducial Marker의 Artifact에 관한 연구 (Consideration of the Effect of Artifact during the Image Guided Radiation Therapy Using the Fiducial Marker)

  • 김종민;김대섭;백금문;강태영;홍동기;윤화룡;권경태
    • 대한방사선치료학회지
    • /
    • 제22권1호
    • /
    • pp.1-10
    • /
    • 2010
  • 목 적: Fiducial marker를 이용하여 움직이는 장기인 간암의 영상유도 방사선 치료 시 fiducial marker에서 발생하는 artifact의 영향에 대하여 알아보고자 한다. 대상 및 방법: 영상 유도 시스템과 CT simulator를 사용하여 고정된 fiducial marker의 artifact 크기 측정, 움직이는 fiducial marker 궤적의 길이 측정과 2차원 정합과 3차원 정합을 각각 시행하였으며, 이때 couch의 좌표 이동 값을 분석하였다. 결 과: 고정된 3.00 mm 크기의 fiducial marker artifact 크기 측정 결과 기준 CT 슬라이스 두께 1.25, 2.50, 5.00, 10.00 mm에서 CT 4.90, 8.10, 12.90, 19.70 mm, 온 보드 영상장치 5.60, 10.60, 14.70, 29.40 mm로 측정되었고, 40.00 mm로 움직이는 fiducial marker 궤적의 길이를 측정한 결과 CT 42.00, 43.10, 46.50 mm, 온 보드 영상장치 43.40, 46.0, 49.30 mm로 측정되었다. 2차원 정합과 3차원 정합 사이에 1.00, 2.00, 8.00 mm의 좌표 이동이 발생하였다. 결 론: Fiducial marker를 이용하여 영상 유도 방사선 치료를 시행 할 때 fiducial marker에서 발생하는 artifact를 고려하여 slice thickness를 2.50 mm 이하로 설정하는 것이 치료 오차를 최소화 할 수 있는 방법이라 생각한다.

  • PDF

Stimulus Artifact Suppression Using the Stimulation Synchronous Adaptive Impulse Correlated Filter for Surface EMG Application

  • Yeom, Ho-Jun;Park, Ho-Dong;Chang, Young-Hui;Park, Young-Chol;Lee, Kyoung-Joung
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권3호
    • /
    • pp.451-458
    • /
    • 2012
  • The voluntary EMG (vEMG) signal from electrically stimulated muscle is very useful for feedback control in functional electrical stimulation. However, the recorded EMG signal from surface electrodes has unwanted stimulation artifact and M-wave as well as vEMG. Here, we propose an event-synchronous adaptive digital filter for the suppression of stimulation artifact and M-wave in this application. The proposed method requires a simple experimental setup that does not require extra hardware connections to obtain the reference signals of adaptive digital filter. For evaluating the efficiency of this proposed method, the filter was tested and compared with a least square (LS) algorithm using previously measured data. We conclude that the cancellation of both primary and residual stimulation artifacts is enhanced with an event-synchronous adaptive digital filter and shows promise for clinical application to rehabilitate paretic limbs. Moreover because this algorithm is far simpler than the LS algorithm, it is portable and ready for real-time application.

가속도계를 이용한 광전용적맥파의 동잡음 제거 (A Study on Accelerometer Based Motion Artifact Reduction in Photoplethysmography Signal)

  • 강정훈;조백환;이종실;지영준;김인영;김선일
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권3호
    • /
    • pp.369-376
    • /
    • 2007
  • With the convergence of ubiquitous networking and medical technologies, ubiquitous healthcare(U-Healthcare) service has come in our life, which enables a patient to receive medical services at anytime and anywhere. In the u-Healthcare environment, intelligent real-time biosignal aquisition/analysis techniques are inevitable. In this study, we propose a motion artifact cancelation method in portable photoplethysmography(PPG) signal aquisition using an accelerometer and an adaptive filter. A preliminary experiment represented that the component of the pedestrian motion artifact can be found under 5Hz in the spectral analysis. Therefore, we collected PPG signals under both simulated conditions with a motor that generates circular motion with uniform velocity (from 1 to 5Hz) and a real walking condition. We then reduced the motion artifact using a recursive least square adaptive filter which takes the accelerometer output as a noise reference. The results showed that the adaptive filter can remove the motion artifact effectively and recover peak points in PPG signals, which represents our method can be useful to detect heart rate in real walking condition.