• Title/Summary/Keyword: Reduction of Wall Thickness

Search Result 134, Processing Time 0.024 seconds

Comparison of Simulated PEC Probe Performance for Detecting Wall Thickness Reduction

  • Shin, Young-Kil;Choi, Dong-Myung;Jung, Hee-Sung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.6
    • /
    • pp.563-569
    • /
    • 2009
  • In this paper, four different types of pulsed eddy current(PEC) probe are designed and their performance of detecting wall thickness reduction is compared. By using the backward difference method in time and the finite element method in space, PEC signals from various thickness and materials are numerically calculated and three features of the signal are selected. Since PEC signals and features are obtained by various types and sizes of probe, the comparison is made through the normalized features which reflect the sensitivity of the feature to thickness reduction. The normalized features indicate that the shielded reflection probe provides the best sensitivity to wall thickness reduction for all three signal features. Results show that the best sensitivity to thickness reduction can be achieved by the peak value, but also suggest that the time to peak can be a good candidate because of its linear relationship with the thickness variation.

Selection of the Large Diameter Pipe Wall Thickness by Value Engineering for a Plant (플랜트에서 가치공학 개념을 적용한 대관경 배관두께 선정에 관한 연구)

  • Choi, Gayoung;Yoo, Hoseon;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.7 no.3
    • /
    • pp.65-73
    • /
    • 2011
  • This research has suggested a method to select pipe wall thickness by application of the value engineering to reduce the cost and quantity that are major part of construction materials. This research shows that the application of value engineering reduces the cost of piping materials by optimizing pipe wall thickness while maintaining process flow date of design pressure and design temperature. Based on this knowledge, the application of the value engineering will lead to the cost reduction and quantity reduction by effective selection of pipe wall thickness. The application of the value engineering will help the EPC companies to win a contract in the overseas plant market.

  • PDF

Shear Spinning of Ti-6Al-4V Alloy at Hot Working Temperature (Ti-6Al-4V 합금의 열간 전단 스피닝)

  • Lee, H.S.;Song, Y.B.;Hong, S.S.
    • Transactions of Materials Processing
    • /
    • v.20 no.6
    • /
    • pp.432-438
    • /
    • 2011
  • A method for estimating the shear spinnability is suggested, and it was applied to sheets of Ti-6Al-4V alloy for estimation of shear spinnability at hot working temperature. The effective working temperature was $850^{\circ}C$ or above. The hot spinning operation was carried out in two steps of shear spinning. The reduction of thickness at the first step was 50% and 45% at the second, and the overall reduction of thickness was 72.4%. The cone spinning process could produce a uniform wall thickness with only a few percent tolerance, proving itself appropriate for making cones of Ti-6Al-4V alloy with uniform wall thickness.

Development of wall-thinning evaluation procedure for nuclear power plant piping - Part 2: Local wall-thinning estimation method

  • Yun, Hun;Moon, Seung-Jae;Oh, Young-Jin
    • Nuclear Engineering and Technology
    • /
    • v.52 no.9
    • /
    • pp.2119-2129
    • /
    • 2020
  • Flow-accelerated corrosion (FAC), liquid droplet impingement erosion (LDIE), cavitation and flashing can cause continuous wall-thinning in nuclear secondary pipes. In order to prevent pipe rupture events resulting from the wall-thinning, most NPPs (nuclear power plants) implement their management programs, which include periodic thickness inspection using UT (ultrasonic test). Meanwhile, it is well known in field experiences that the thickness measurement errors (or deviations) are often comparable with the amount of thickness reduction. Because of these errors, it is difficult to estimate wall-thinning exactly whether the significant thinning has occurred in the inspected components or not. In the previous study, the authors presented an approximate estimation procedure as the first step for thickness measurement deviations at each inspected component and the statistical & quantitative characteristics of the measurement deviations using plant experience data. In this study, statistical significance was quantified for the current methods used for wall-thinning determination. Also, the authors proposed new estimation procedures for determining local wall-thinning to overcome the weakness of the current methods, in which the proposed procedure is based on analysis of variance (ANOVA) method using subgrouping of measured thinning values at all measurement grids. The new procedures were also quantified for their statistical significance. As the results, it is confirmed that the new methods have better estimation confidence than the methods having used until now.

An Optimum Design of Pipe Bending Process Using High Frequency Induction Heating and Dynamic Reverse Moment (고주파 유도가열 및 동적 반력 모멘트를 이용한 파이프 벤딩 공정의 최적설계)

  • Lee, H.W.;Jung, S.Y.;Woo, T.K.;Kim, C.
    • Transactions of Materials Processing
    • /
    • v.19 no.2
    • /
    • pp.79-87
    • /
    • 2010
  • The Pipe bending process using high frequency local induction heating is an advanced technique to bend pipes with a small bending radius and a large diameter. Even though the pipe bending process is a quite widespread engineering practice, it depends heavily upon trial and error method by field engineers with several years of experience. So it is necessary to develop an integrated methodology for optimum design of the pipe bending process. During hot pipe bending using induction heating, outward wall thickness of a pipe is thinned due to tensile stress and the reduction of wall thickness is not allowed to exceed 12.5%. Taguchi method and dynamic reverse moment is proposed to maintain a reduction ratio of thickness within 12.5%, when D/t ratio is high. An application of the proposed approach was compared with those of the finite element analysis and has good in agreements.

Creep Analysis on Pressure Tube Wall Thickness Variation

  • Kim, Jung-Gyu;Hwang, Jong-Keun;Park, Keon-Woo;Kim, Tae-Hyung;Rhee, Hui-Nam
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.295-299
    • /
    • 1996
  • This analysis is to investigate the benefits and disadvantages of increasing the pressure tube wall thickness for CANDU reactor. Creep analysis of the pressure tube was performed for slightly enriched uranium (SEU) to establish the reduction in axial elogation and diametral creep provided by a thicker wall pressure tube.

  • PDF

Long Range Ultrasonic Guided Wave Techniques for Inspection of Pipes (유도초음파를 이용한 장거리 배관 탐상기법)

  • Park, Ik-Keun;Kim, Yong-Kwon;Kim, Hyun-Mook;Song, Won-Joon;Cho, Yong-Sang;Ahn, Yeon-Shik
    • Journal of Welding and Joining
    • /
    • v.23 no.5
    • /
    • pp.43-48
    • /
    • 2005
  • Conventional non-destructive techniques for inspection of the weld in pipelines require significant test time and high cost. Ultrasonic guided waves have been widely studied and successfully applied to various non-destructive tests with advantage of the long-range inspection. In this paper, a study on the application of ultrasonic guided waves to the long-range inspection of the pipeline is presented using a long-range guided wave inspection system, Wavemaker SE16, GUL. The characteristics and setup of the long-range guided wave inspection system and experimental results in pipes of with various diameter are introduced. The experimental results in mock-up pipes with cluster type detects show that the minimum detectable wall thickness reduction with this guided wave system is $2\~3\%$ in the pipe cross section area. And the wall thickness reduction of $5\%$ in cross section area can be detected when actual detection level is used. Therefore, the applicability of the guided wave systeme to long-range inspection of wall thickness reduction in pipes is verified.

A Study on the Thermal Load Patterns for a Exterior Wall in a House According to a Variation of Earth Sheltering Thickness (복토 주택의 외벽면 복토 두께 변화에 따른 열부하 패턴에 관한 연구)

  • Lee, Jae-Hyuk;Choi, Won-Ki;Suh, Seung-Jik;Cho, Dong-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.807-812
    • /
    • 2008
  • The various attempts is made to solve the energy and environment problems. In addition, people interested in their life quality want the more eco-friendly living space. So we suggested that the earth-sheltered house could be one of the eco-friendly and low energy consuming houses to meet the social interest. And we also made data for design of the earth-sheltered house to be applicable to climate of Korea. In this study, a simulation was performed to estimate a boundary temperature according to earth sheltering thickness at the earth-sheltered part(exterior wall) in the case of earth sheltering on the plane ground not using a sloped site. And we analyzed the reduction of a thermal load by using this boundary temperature. We also compared a case of earth sheltering at the vertical wall with a case of earth sheltering at the roof to know the thermal reduction effect of a case of earth sheltering at the vertical wall.

  • PDF

STUDY OF THE CHANGES IN CANAL WALL THICKNESS AND THE AREA OF THE CROSS SECTION OF THE ROOT IN THE MESIAL ROOT OF THE MANDIBULAR MOLAR CANAL PREPARATION (하악 대구치 근심치근의 근관 형성방법에 따른 각 부위별 근관벽 후경 및 근관 면적의 변화에 관한 연구)

  • Park, Jong-Gwan;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.1
    • /
    • pp.73-84
    • /
    • 1994
  • Using a model system that can compare the before and after of canal preparation in the same tooth, we measured the area of the cross section, and canal wall thickness of the distal portion of the mesial root of the mandibular molar, and compared the amount of reduction in the canal using hand flared preparation the Gates-Glidden drill flared preparation according to the changes in the MAF. The results were as follows. 1. After canal preparation, the canal wall thickness had no significant difference between the hand flared preparation and Gates-Glidden drill flared preparation. 2. The canal wall thickness, after canal preparation, there was no significant difference between the sizes of the MAF. 3. The area variation range of each cross section of root had no significant difference between MAF size and methods of canal preparation. 4. After canal preparation, the frequency of the canal wall thickness under 0.5mm showed 3.5mm below the furcation to be the most frequent with statistical significance(p<0.05). 2mm below the furcation and 5mm below the furcation followed but there was no statistical significance. 5. The danger zone of the mesial root of the mandibular molar seems to be around 3.5mm.

  • PDF

Dose Reduction of the Adolescent Female Breast during Scoliosis Radiography (청소년기 여성의 척추측만증 검사에서 유방입사선량 저감효과)

  • Jin, Gye Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.373-379
    • /
    • 2018
  • The purpose of this study was to investigate quantitative data on the difference in breast entrance surface dose with changes in focus-film distance, patient posture (anteroposterior-posteroanterior), thoracic wall thickness, rib bone thickness, lung tissue thickness, tube voltage, and high-voltage rectification method in Whole Spine Scanography, which is necessary for the treatment of scoliosis patients. Given a tube voltage of 90 kVp, kerma of 0.1 mGy, focus-film distance of 260 cm, tube voltage ripple rate of 0, filter thickness of 3.5 mm, and thickness of patient's thoracic wall of 120 mm as an X-ray exposure condition, from the simulation results using the Simulation of X-ray Spectra program to confirm the reduction effect of breast entrance surface dose according to the patient's posture (AP and PA), there was a dose reduction effect in aluminum filter thickness of 2.6 times at 3.5 mm, 25.7 times the thoracic wall thickness at 120 mm, 1.43 times higher tube voltage, and 0 to 1.14 times the tube voltage ripple rate. The total dose reduction effect was about 109 times. In order to confirm the dose reduction effect of RANDO phantom posture (AP and PA), from the results of the measurements taken under the conditions that the focus-film distance was 260 cm, the tube voltage was 90 kVp, the tube current was 270 mA, the exposure time was 0.31 sec, and the tube voltage ripple rate of X-ray generators was 0, the entrance surface dose reduction effect of the breast in the PA position was found to be 20.56 times lower than that of the AP position.