• 제목/요약/키워드: Reduction device

검색결과 1,286건 처리시간 0.026초

일반공조 시스템 대비 축열조와 연동된 수직밀폐형 지열히트펌프의 냉난방 에너지 성능 및 경제성 분석 (Cooling and Heating Energy Performance and Cost Analysis of Vertical Closed-loop Geothermal Heat Pump Coupled with Heat Storage Tank Compared to Conventional HVAC System)

  • 김민지;도성록;최종민;이광호
    • 대한건축학회논문집:구조계
    • /
    • 제34권11호
    • /
    • pp.81-87
    • /
    • 2018
  • Among various types of geothermal heat pump systems, Vertical Closed-Loop Geothermal Heat Pump (VGSHP) has received increasing attention due to a variety of advantages such as the potential to be installed in a relatively small space and improved energy efficiency. In this research, the performance of VGSHP system coupled with heat storage tank was evaluated, by analyzing operational behavior of heat storage tank, the variations of heat pump energy performance due to the connection with heat storage tank, part load ratios characteristics of heat pump and the corresponding energy cost, compared to chiller and boiler based conventional system. The results of this study showed that the VGSHP system coupled with heat storage tank showed an energy saving effect of about 18% for cooling and about 73% for heating, and annual heating/cooling energy cost reduction of 43,000,000 KRW ($ 39,000), compared to the conventional air conditioning system. In addition, after considering both energy cost and initial investment cost including equipment, installation and auxiliary device expenses, payback period of approximately 11.8 years was required.

하악골의 치조골 골삭제를 위한 동적 제약 기구부의 성능에 관한 연구 (A Study on the Performance of Dynamic Restraint Manipulator for Drilling Alveolar Bone in Mandible)

  • 김광호;이동운;정상화
    • 한국기계가공학회지
    • /
    • 제19권12호
    • /
    • pp.105-112
    • /
    • 2020
  • The increase in the edentulous jaw which occurs in the aged population has led to personal dental health concerns. In the case of dental implant surgery, the duration of a patient's recovery depends on the surgical plan and their physicical ability. A device may be required to assist a physician in controlling vibration reduction of free-hand drilling and prescribing a good treatment plan that is suitable for the patient's condition. In this work, an artificial tooth-root implant assistant manipulator was studied. The structure and the vibration analysis of the dynamic restraint manipulator that is for drilling the alveolar bone in the mandible bone were performed, and the structural stability was analyzed. Further, a virtual prototype of an artificial tooth-root implant assisted manipulator was fabricated and tested. Hence, the state of the Remote Center of Motion (RCM) point and the driving state of the manipulator were confirmed. Furthermore, the drilling experiments were performed by using materials similar to a human jawbone in order to evaluate the performance of the drilling process that is operated using the assistant manipulator.

연속저주파를 이용한 미세조류 파쇄 (Analysis of Cell Disruption in Microalgae Using Continuous Low Frequency Non-Focused Ultrasound)

  • 최준혁;김광호;박종락;정상화
    • 한국기계가공학회지
    • /
    • 제20권8호
    • /
    • pp.33-41
    • /
    • 2021
  • Recently, many studies have been conducted on substituting fossil fuels with bio-refineries in existing industrial systems using biomass. Among the various bio-refineries, microalgae have received wide attention because it uses inorganic compounds to produce useful substances, which are extracted by a cell disruption process. Although numerous cell disruption methods exist, cell disruption efficiency has been studied by ultrasonic treatment. Ultrasound is a high-frequency (20 kHz or higher) sound wave and causes cell disruption by cavitation when passing through a solvent. In this study, we used the microalgal species Chlorella sp., which was cultured in a plate-type photobioreactor. The experiment was conducted using a continuous low-frequency processing device. The reduction of cells with time due to cell disruption was fitted using a logistic model, and optimum conditions for highly efficient cell disruption were determined by conducting experiments under multiple conditions.

AES 암호 알고리듬에 대한 반복문 뒷 라운드 축소 공격 (A Late-Round Reduction Attack on the AES Encryption Algorithm Using Fault Injection)

  • 최두식;최용제;최두호;하재철
    • 정보보호학회논문지
    • /
    • 제22권3호
    • /
    • pp.439-445
    • /
    • 2012
  • 오류 주입 공격은 비밀 키를 내장하여 사용하는 암호 장치에서 연산 수행시 공격자가 오류를 주입하는 방법으로 비밀 키를 찾아낼 수 있어 암호시스템 운영의 심각한 위협이 되고 있다. 논문에서는 AES 암호 연산을 수행하는 동안 라운드 함수를 반복적으로 사용하는 경우, 반복하는 구문에 오류를 넣어 한 라운드를 생략하면 쉽게 비밀 키를 추출할 수 있음을 보이고자 한다. 제안하는 공격 방법을 상용 마이크로프로세서에서 실험한 결과, 두 개의 정상-오류 암호문 쌍만 있으면 128비트 AES 비밀 키가 노출됨을 확인하였다.

상시불통형 p-GaN/AlGaN/GaN 이종접합 트랜지스터의 게이트막 농도 계조화 효과 (Gate Field Alleviation by graded gate-doping in Normally-off p-GaN/AlGaN/GaN Hetrojunction FETs)

  • 조성인;김형탁
    • 전기전자학회논문지
    • /
    • 제24권4호
    • /
    • pp.1167-1171
    • /
    • 2020
  • 본 연구에서는 상시불통형 p-GaN 전력반도체소자의 신뢰성 향상을 위해 p-GaN 게이트막 내부의 전계를 완화하고자 p-GaN 게이트 도핑농도의 계조화를 제안한다. TCAD 시뮬레이션으로 균일한 도핑농도를 갖는 소자와 문턱전압과 출력 전류 특성이 동일하도록 p형 농도를 계조화하고 최적화하였다. p-GaN 게이트층에서의 전계 감소로 소자의 게이트 신뢰성이 개선될 수 있을 것으로 판단된다.

Numerical and experimental study on hydrodynamic performance of multi-level OWEC

  • Jungrungruengtaworn, Sirirat;Reabroy, Ratthakrit;Thaweewat, Nonthipat;Hyun, Beom-Soo
    • Ocean Systems Engineering
    • /
    • 제10권4호
    • /
    • pp.359-371
    • /
    • 2020
  • The performance of a multi-level overtopping wave energy converter (OWEC) has been numerically and experimentally investigated in a two-dimensional wave tank in order to study the effects of opening width of additional reservoirs. The device is a fixed OWEC consisting of an inclined ramp together with several reservoirs at different levels. A particle-based numerical simulation utilizing the Lattice Boltzmann Method (LBM) is used to simulate the flow behavior around the OWEC. Additionally, an experimental model is also built and tested in a small wave flume in order to validate the numerical results. A comparison in energy captured performance between single-level and multi-level devices has been proposed using the hydraulic efficiency. The enhancement of power capture performance is accomplished by increasing an overtopping flow rate captured by the extra reservoirs. However, a noticeably large opening of the extra reservoirs can result in a reduction in the power efficiency. The overtopping flow behavior into the reservoirs is also presented and discussed. Moreover, the results of hydrodynamic performance are compared with a similar study, of which a similar tendency is achieved. Nevertheless, the LBM simulations consume less computational time in both pre-processing and calculating phases.

Effect of Oxidation Behavior of (Nd,Dy)-Fe-B Magnet on Heavy Rare Earth Extraction Process

  • 박상민;남선우;이상훈;송명석;김택수
    • 한국분말재료학회지
    • /
    • 제28권2호
    • /
    • pp.91-96
    • /
    • 2021
  • Rare earth magnets with excellent magnetic properties are indispensable in the electric device, wind turbine, and e-mobility industries. The demand for the development of eco-friendly recycling techniques has increased to realize sustainable green technology, and the supply of rare earth resources, which are critical for the production of permanent magnets, are limited. Liquid metal extraction (LME), which is a type of pyrometallurgical recycling, is known to selectively extract the metal forms of rare earth elements. Although several studies have been carried out on the formation of intermetallic compounds and oxides, the effect of oxide formation on the extraction efficiency in the LME process remains unknown. In this study, microstructural and phase analyses are conducted to confirm the oxidation behavior of magnets pulverized by a jaw crusher. The LME process is performed with pulverized scrap, and extraction percentages are calculated to confirm the effect of the oxide phases on the extraction of Dy during the reaction. During the L ME process, Nd is completely extracted after 6 h, while Dy remains as Dy2Fe17 and Dy-oxide. Because the decomposition rate of Dy2Fe17 is faster than the reduction rate of Dy-oxide, the importance of controlling Dy-oxide on Dy extraction is confirmed.

외국인투자가 탄소배출량에 미치는 영향분석: 패널 VAR 모형을 이용한 분석 (Analysis of the Influence of Foreign Direct Investment on Carbon Emissions: Analysis Using Panel VAR Model)

  • 류승우;이양기;김능우
    • 무역학회지
    • /
    • 제44권1호
    • /
    • pp.45-56
    • /
    • 2019
  • The purpose of this study is to investigate the relationship between foreign investment and carbon emissions in the Korean electricity sector, the causal relationship between the foreign investment invested in the electric power sector in the 16 regional regions and the carbon emissions in the region, The purpose of this study is to analyze the effects of foreign investment on these sectors and the carbon footprint of these sectors using Panel Random Effect Analysis, Panel VAR and OLS models. A panel analysis of foreign investment and regional carbon emissions showed that there was a causal relationship. Based on this analysis, OLS analysis showed that 7 out of 16 metropolitan areas were foreign investment And carbon emissions were significant. In the remaining six regions except Gwangju, there was a causal relationship between foreign investment in the local power sector and the reduction of carbon emissions. After categorizing the electric power industry by device, process, purpose and number of employees, causality also appeared in relation to foreign investment in these sectors and their carbon emissions. Through this study, the authors suggest that foreign investment can be a way to solve not only the financial burden of carbon emission problem, but also the development of national economy and industry through the inflow of capital and advanced new technology.

Effect of electric field on primary dark pulses in SPADs for advanced radiation detection applications

  • Lim, Kyung Taek;Kim, Hyoungtaek;Kim, Jinhwan;Cho, Gyuseong
    • Nuclear Engineering and Technology
    • /
    • 제53권2호
    • /
    • pp.618-625
    • /
    • 2021
  • In this paper, the single-photon avalanche diodes (SPADs) featuring three different p-well implantation doses (∅p-well) of 5.0 × 1012, 4.0 × 1012, and 3.0 × 1012 atoms/cm2 under the identical device layouts were fabricated and characterized to evaluate the effects of field enhanced mechanisms on primary dark pulses due to the maximum electric field. From the I-V curves, the breakdown voltages were found as 23.2 V, 40.5 V, and 63.1 V with decreasing ∅p-well, respectively. By measuring DCRs as a function of temperature, we found a reduction of approximately 8% in the maximum electric field lead to a nearly 72% decrease in the DCR at Vex = 5 V and T = 25 ℃. Also, the activation energy increased from 0.43 eV to 0.50 eV, as decreasing the maximum electric field. Finally, we discuss the importance of electric field engineering in reducing the field-enhanced mechanisms contributing to the DCR in SPADs and the benefits on the SPADs related to different types of radiation detection applications.

Numerical Analysis for Hydrodynamic Performance of OWC Devices with Multiple Chambers in Waves

  • Kim, Jeong-Seok;Nam, Bo Woo
    • 한국해양공학회지
    • /
    • 제36권1호
    • /
    • pp.21-31
    • /
    • 2022
  • In recent years, various studies have been conducted on oscillating-water-column-type wave energy converters (OWC-WECs) with multiple chambers with the objective of efficiently utilizing the limited space of offshore/onshore structures. In this study, a numerical investigation based on a numerical wave tank was conducted on single, dual, and triple OWC chambers to examine the hydrodynamic performances and the energy conversion characteristics of the multiple water columns. The boundary value problem with the Laplace equation was solved by using a numerical wave tank based on a finite element method. The validity of the current numerical method was confirmed by comparing it with the measured data in the previous experimental research. We undertook a series of numerical simulations and observed that the water column motion of sloshing mode in a single chamber can be changed into the piston motion of different phases in multiple OWC chambers. Therefore, the piston motion in the multiple chambers can generate considerable airflow at a specific resonant frequency. In addition, the division of the OWC chamber results in a reduction of the time-dependent variability of the final output power from the device. As a result, the application of the multiple chambers leads to an increase of the energy conversion performance as well as a decrease of the variability of the wave energy converter.