• Title/Summary/Keyword: Reduction device

Search Result 1,293, Processing Time 0.032 seconds

Communication-Power Overhead Reduction Method Using Template-Based Linear Approximation in Lightweight ECG Measurement Embedded Device (경량화된 심전도 측정 임베디드 장비에서 템플릿 기반 직선근사화를 이용한 통신오버헤드 감소 기법)

  • Lee, Seungmin;Park, Kil-Houm;Park, Daejin
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.15 no.5
    • /
    • pp.205-214
    • /
    • 2020
  • With the recent development of hardware and software technology, interest in the development of wearable devices is increasing. In particular, wearable devices require algorithms suitable for low-power and low-capacity embedded devices. Among them, there is an increasing demand for a signal compression algorithm that reduces communication overhead, in order to increase the efficiency of storage and transmission of electrocardiogram (ECG) signals requiring long-time measurement. Because normal beats occupy most of the signal with similar shapes, a high rate of signal compression is possible if normal beats are represented by a template. In this paper, we propose an algorithm for determining the normal beat template using the template cluster and Pearson similarity. Also, the template is expressed effectively as a few vertices through linear approximation algorithm. In experiment of Datum 234 of MIT-BIH arrhythmia database (MIT-BIH ADB) provided by Physionet, a compression ratio was 33.44:1, and an average distribution of root mean square error (RMSE) was 1.55%.

Development of Heat System for Productivity Improvement of Ball Press Pushing up Equipment (볼 프레스 압입장치의 생산성 향상을 위한 예열시스템 개발)

  • Chai, Yong-Yoong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.11
    • /
    • pp.1101-1106
    • /
    • 2016
  • In this thesis, I developed a ball press pushing up equipment to solve the defect that occurs when the ball is inserted to the auto transmission. The ball press pushing up equipment is composed of heating device, thermostat which controls the heating device and the automated insertion device which helps to enhance mass production. This development contributes to quality improvement of domestic automobile production auto transmission part, and also contribute to cost reduction and sales increase for corporations.

The Ligthning Surge Protective Devices with Combination of Varistor and LC Filter (바리스터와 LC필터를 조합한 뇌써-지보호장치)

  • Kim, J.H.;Lee, K.O.;Lee, B.H.;Lee, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1873-1875
    • /
    • 1996
  • This paper deals with the lightning surge protective devices with combination of varistor and LC filter. UP to now, the varistor alone were used as overvoltage protection devices fer the AC power mains. In this work, in order to improve the cutoff performance of surge protective device, the hybrid circuit surge protective device for an AC single phase mains was designed and investigated. The first stage of hybrid circuit is to remove most of any large surge energy and protect the second stage components. The purpose of the second is to protect the load and increase the cutoff capacity of surge protective devices. Also LC filter attenuates the remnant that travels downstream from the first stage component and the high frequency noises. As a consequence, it was found that the proposed hybrid surge protective device for AC power mains has a variety of advantages such as low and tight clamping voltage, high frequency noise reduction and large cutoff capacity.

  • PDF

Study of a Gravity Compensator for the Lower Body (중력보상기 기반의 하지용 외골격 장치 설계 연구)

  • Choi, Hyeung-Sik;Kim, Dong-Ho;Jeon, Ji-Kwang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.4
    • /
    • pp.455-462
    • /
    • 2011
  • This paper is about the design of a new gravity compensator for the lower body exo-skeleton device. The exo-skeleton devices is for increasing the torque of the human body joint for the purpose of helping the disabled, workers in the industry, and military soldiers. So far, most of studied exo-skeleton devices are actuated by the motors, but motors are limited in energy such that a short durability is always a big problem. In this paper, a new gravity compensator is proposed to reduce the torque load applied to human body joints due to gravity. The gravity compensator is designed using a tortional bar spring, and its structure and characteristics are studied through the test and computer simulation. A design concept on the exo-skeleton device using the gravity compensator is presented. An analysis and computer simulation on the torque reduction of the proposed exo-skeleton device that applies and non-applies the gravity compensator are performed.

The Design and Implementation of IoT-Based Radon Measurement Control System (IoT 기반 라돈 측정 제어시스템 설계 및 구현)

  • Ahn, Heuihak;Gu, Jayeong;Lee, Sangyoon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.16 no.1
    • /
    • pp.1-10
    • /
    • 2020
  • This paper is a IoT-based radon meter control system and a radon meter control method using it. The IoT-based radon meter control system is control system for controlling a radon meter by network-connecting radon meter and a user terminal. The radon measuring device may be provided with a radon sensor to measure a radon value of a preset management target area, it collect and store numerical data. The radon meter control system monitors the condition of the radon meter, it includes control center configured to deliver radon meter management information generated to a user terminal. Also radon measurements to determine the exact amount of radon gas. Therefore, the situation-specific actions based on radon numbers can be promptly implemented to ensure adequate protection for those who are vulnerable to radon and those who live in the area. Condition monitoring allows the radon meter to respond quickly to failure or failure of the radon meter. In addition, it is possible to secure a baseline of radon's influence and to obtain research data to cope with radon by establishing big data with radon measurements.

Development of the S/G TSP Clogging Image Analysis Algorithm (증기발생기 유로홈막힘 사진판독 알고리즘 개발)

  • Cho, Nam Cheoul;Kim, Wang Bae;Moon, Chan Kook
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.3
    • /
    • pp.8-14
    • /
    • 2011
  • The clogging of the flow area at the tube support plates(TSPs), especially at the upper TSPs results in the water level oscillation of a steam generator during normal operation. A reduction of the TSP flow area causes to increase in pressure drop within the two-phase flow zone, which destabilizes the boiling flow through the tube bundle. This phenomenon was occasionally observed at a few domestic and foreign nuclear power plants. One of the methods for defining the flow area clogging is visual inspection, which is the most effective inspection method. The results of the visual inspection for TSPs' flow area are clogging images on TSPs' quartrefoil lobes. These images are complexly distorted due to lens aberration and external factors like the distance to a subject and angle etc. In this work, we developed the analysis algorithm for clogging image of the TSP flow area of steam generators. For this purpose, we designed an image verification device applicable to the camera employed in the field for visual inspection and then, we demonstrated the validity of image analysis algorithm by using this device and commercial autoCAD program.

DC and RF Characteristics of $0.15{\mu}m$ Power Metamorphic HEMTs

  • Shim, Jae-Yeob;Yoon, Hyung-Sup;Kang, Dong-Min;Hong, Ju-Yeon;Lee, Kyung-Ho
    • ETRI Journal
    • /
    • v.27 no.6
    • /
    • pp.685-690
    • /
    • 2005
  • DC and RF characteristics of $0.15{\mu}m$ GaAs power metamorphic high electron mobility transistors (MHEMT) have been investigated. The $0.15{\mu}m{\times}100{\mu}m$ MHEMT device shows a drain saturation current of 480 mA/mm, an extrinsic transconductance of 830 mS/mm, and a threshold voltage of -0.65 V. Uniformities of the threshold voltage and the maximum extrinsic transconductance across a 4-inch wafer were 8.3% and 5.1%, respectively. The obtained cut-off frequency and maximum frequency of oscillation are 141 GHz and 243 GHz, respectively. The $8{\times}50{\mu}m$ MHEMT device shows 33.2% power-added efficiency, an 18.1 dB power gain, and a 28.2 mW output power. A very low minimum noise figure of 0.79 dB and an associated gain of 10.56 dB at 26 GHz are obtained for the power MHEMT with an indium content of 53% in the InGaAs channel. This excellent noise characteristic is attributed to the drastic reduction of gate resistance by the T-shaped gate with a wide head and improved device performance. This power MHEMT technology can be used toward 77 GHz band applications.

  • PDF

Fabrication and Device Performance of Tera Bit Level Nano-scaled SONOS Flash Memories (테라비트급 나노 스케일 SONOS 플래시 메모리 제작 및 소자 특성 평가)

  • Kim, Joo-Yeon;Kim, Moon-Kyung;Kim, Byung-Cheul;Kim, Jung-Woo;Seo, Kwang-Yell
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.12
    • /
    • pp.1017-1021
    • /
    • 2007
  • To implement tera bit level non-volatile memories of low power and fast operation, proving statistical reproductivity and satisfying reliabilities at the nano-scale are a key challenge. We fabricate the charge trapping nano scaled SONOS unit memories and 64 bit flash arrays and evaluate reliability and performance of them. In case of the dielectric stack thickness of 4.5 /9.3 /6.5 nm with the channel width and length of 34 nm and 31nm respectively, the device has about 3.5 V threshold voltage shift with write voltage of $10\;{\mu}s$, 15 V and erase voltage of 10 ms, -15 V. And retention and endurance characteristics are above 10 years and $10^5$ cycle, respectively. The device with LDD(Lightly Doped Drain) process shows reduction of short channel effect and GIDL(Gate Induced Drain Leakage) current. Moreover we investigate three different types of flash memory arrays.

Development of Walking Assistant Controller for Patients with Weakness in Cardiopulmonary System (심폐기능 허약자를 위한 보행보조장치 제어기 개발)

  • Kang, S.J.;Kim, G.S.;P, S.H.;Mun, M.S.;Sei, S.W.;Kim, J.K.;Ryu, J.C.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.4 no.1
    • /
    • pp.23-28
    • /
    • 2010
  • Case of patients with weakness in cardiopulmonary system, other ambulatory function is normal, but oxygen supply function is problem. So they need reduce energy consumption for gait by assistance system. In this study, we designed and developed walking assistant device which helps flexion and extension of hip joint for cardiopulmonary patients. There are two motors, each at the left and right side of pelvis, providing torque to the hip joint. The target angle of the flexion and extension in the hip joint is set according to the normal gait. As a result, reduction of energy consumption was 14.8% by gait assistive device.

Functionally upgraded passive devices for seismic response reduction

  • Chen, Genda;Lu, Lyan-Ywan
    • Smart Structures and Systems
    • /
    • v.4 no.6
    • /
    • pp.741-757
    • /
    • 2008
  • The research field of structural control has evolved from the development of passive devices since 1970s, through the intensive investigation on active systems in 1980s, to the recent studies of semi-active control systems in 1990s. Currently semi-active control is considered most promising in civil engineering applications. However, actual implementation of semi-active devices is still limited due mainly to their system maintenance and associated long-term reliability as a result of power requirement. In this paper, the concept of functionally upgraded passive devices is introduced to streamline some of the state-of-the-art researches and guide the development of new passive devices that can mimic the function of their corresponding semi-active control devices for various applications. The general characteristics of this special group of passive devices are discussed and representative examples are summarized. Their superior performances are illustrated with cyclic and shake table tests of two example devices: mass-variable tuned liquid damper and friction-pendulum bearing with a variable sliding surface curvature.