• Title/Summary/Keyword: Reduction Techniques

Search Result 1,590, Processing Time 0.032 seconds

A Study on the Seismic Performance of MR Fluid Dampers in Base-Isolated Structures (기초격리된 구조물에서 자기유동성 유체감쇠기의 면진성능에 관한 연구)

  • 이종세;도학용
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.09a
    • /
    • pp.371-378
    • /
    • 2002
  • The design concepts using vibration reduction techniques, or structural control, have been proposed recently to protect infrastructure against earthquakes. The magnetorheological(MR) fluid damper is one of the most promising new devices for structural vibration reduction because of its mechanical simplicity, high dynamic range, low power requirement, large force capacity and robustness. In this study, the seismic performance of MR devices are compared with that of NZ systems as an attempt to provide some data for improving seismic design techniques applied to structures. For nonlinear time domain analysis of a base isolation system, a six-story building model is considered as a numerical example. The ground acceleration data of El Centre 1940, Mexico City 1985 and Kobe 1995 earthquakes are used as seismic excitations. The results show that MR damper systems for outperform NZ systems in wide-ranging seismic excitations with respect to intensity and period characteristics.

  • PDF

Efficiency of Estimation for Parameters by Use of Variance Reduction Techniques (분산감소기법을 이용한 파라미터 추정의 효율성)

  • Whang Sung-won;Kwon Chi-myung;Kim Sung-yeon
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2005.05a
    • /
    • pp.45-49
    • /
    • 2005
  • 본 연구는 시뮬레이션 반응변수가 입력 인자의 선형 1차식으로 표현된 경우에 인자의 파라미터를 효과적으로 추정하기위해 사용될 수 있는 분산감소기법을 제안하였다. 이 기법은 하나의 실험설계에 공통난수와 대조난수를 동시에 사용하는 Schruben과 Margolin의 방법과 시뮬레이션하는 도중에 얻어지는 통제변수를 활용하는 기법을 결합하는 방법으로 시뮬레이션의 효율성을 개선하고자 하였다. 시뮬레이션 결과 제안된 기법은 주어진 모형의 평균 반응치를 추정한 데는 S-M 기법보다 효과적이었으며 인자의 다른 파라미터를 추정하는 데는 S-M 기법과 비슷한 성과를 보이고 있다. 만일 시뮬레이션 과정에서 반응변수와 상관성이 높은 통제변수들을 선택할 수 있는 경우에는 제안된 기법이 S-M 기법보다 보다 파라미터 추정에 효과적일 것으로 판단된다.

  • PDF

A Study of Noise Reduction in Hard Disk Drive (하드디스크 드라이브에서의 소음 저감에 관한 연구)

  • 곽주영;손진승;이행수;홍민표;고정석;조은형;좌성훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.579-585
    • /
    • 2001
  • This paper proposed a method of reducing a noise in hard disk drive. This method is performed through three parts of procedures. First procedure is sound-oriented experiment, which contains sound intensity techniques and measurements of sound pressure level and sound power. Second is vibration-oriented experiment, which contains FRF(Frequency Response Function) analysis and disk vibration reduction techniques. And the third is computer-oriented simulation, which contains modal analysis and force vibration analysis using ANSYS and sound radiation prediction using SYSNOISE. As these three parts can affect with each other, they should be considered and conducted simultaneously. Through this procedure sound power is measured 2.7 Bels in idle-spinning mode, which is the lowest noise level in the HDD industries.

  • PDF

Study on Soot Primary Particle Size Measurement in Ethylene Diffusion Flame by Time-Resolved Laser-Induced Incandescence (시분해 레이저 유도 백열법을 이용한 에틸렌 확산 화염에서의 매연 일차입자크기 측정에 관한 연구)

  • Kim Gyu-Bo;Cho Seung-Wan;Lee Jong-Ho;Jeong Dong-Soo;Chang Young-June;Jeon Chung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.10 s.253
    • /
    • pp.973-981
    • /
    • 2006
  • Recently there is an increasing interest in particulate matter emission because of new emission regulations, health awareness and environmental problems. It requires to improve particulate measurement techniques as well as to reduce soot emissions from combustion systems. As mentioned above, it is demanded that reduction techniques together with measurement techniques of exhausted particulate matters in combustion systems such as vehicles. However, measurement techniques of particulate matters should be prior to reduction techniques of that because it is able to know an increase and a decrease of exhausted particulate matters when measured particulate matters. Therefore, in this study, we report the measurement of soot primary-particle size using time-resolved laser induced incandescence (TIRE-LII) technique in laminar ethylene diffusion flame. As an optical method, laser induced incandescence is one of well known methods to get information for spatial and temporal soot volume fraction and soot primary particle size. Furthermore, TIRE-LII is able to measure soot primary particle size that is decided to solve the decay ate of signal S $(t_1)$ and S $(t_2)$ at two detection time. In laminar ethylene diffusion flame, visual flame height is 40 mm from burner tip and measurement points are height of 15, 20, 27.5, 30 mm above burner tip along radial direction. As increasing the height of the flame from burne. tip, primary particle size was increased to HAB(Height Above Burner tip)=20mm, and then decreased from HAB=27.5 mm to 30 mm. This results show the growth and oxidation processes for soot particles formed by combustion.

Standby Power Reduction Technique due to the Minimization of voltage difference between input and output in AC 60Hz (대기전력 최소화를 위한 교류전압 입력에 따른 저전압 구동회로 설계)

  • Seo, Kil-Soo;Kim, Ki-Hyun;Kim, Hyung-Woo;Lee, Kyung-Ho;Kim, Jong-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1018-1019
    • /
    • 2015
  • Recently, standby power reduction techniques of AC/DC adaptor were developed, consuming power almost arrived to 300mW level. The standby power losses are composed of the input filter loss 11.8mW, the control IC for AC/DC adaptor 18mW, the switching loss 9.53mW and the feedback loss 123mW. And there are the standby power reduction techniques. In this paper, in order to reduce the standby power of SMPS more, the loss due to a voltage difference between input and output is reduced by the control circuit which is composed of the low voltage driving circuit and voltage regulator. The low voltage driving circuit operates on the low voltage of input and off the high voltage. The low voltage driving IC was produced by the $1.0{\mu}m$, high voltage DMOS process.

  • PDF

Long Range Ultrasonic Guided Wave Techniques for Inspection of Pipes (유도초음파를 이용한 장거리 배관 탐상기법)

  • Park, Ik-Keun;Kim, Yong-Kwon;Kim, Hyun-Mook;Song, Won-Joon;Cho, Yong-Sang;Ahn, Yeon-Shik
    • Journal of Welding and Joining
    • /
    • v.23 no.5
    • /
    • pp.43-48
    • /
    • 2005
  • Conventional non-destructive techniques for inspection of the weld in pipelines require significant test time and high cost. Ultrasonic guided waves have been widely studied and successfully applied to various non-destructive tests with advantage of the long-range inspection. In this paper, a study on the application of ultrasonic guided waves to the long-range inspection of the pipeline is presented using a long-range guided wave inspection system, Wavemaker SE16, GUL. The characteristics and setup of the long-range guided wave inspection system and experimental results in pipes of with various diameter are introduced. The experimental results in mock-up pipes with cluster type detects show that the minimum detectable wall thickness reduction with this guided wave system is $2\~3\%$ in the pipe cross section area. And the wall thickness reduction of $5\%$ in cross section area can be detected when actual detection level is used. Therefore, the applicability of the guided wave systeme to long-range inspection of wall thickness reduction in pipes is verified.

Minimally Invasive Plate Osteosynthesis of Radius-Ulna Fracture using Circular External Fixator in a Dog

  • Kwon, Yong-hwan;Kang, Jin-su;Kim, Young-ung;Cho, Hyoung-sun;Lee, Ki-chang;Kim, Nam-soo;Kim, Min-su
    • Journal of Veterinary Clinics
    • /
    • v.34 no.1
    • /
    • pp.47-49
    • /
    • 2017
  • Fracture stabilization techniques continue to evolve and provide approaches that minimize the iatrogenic trauma associated with surgical procedures. Minimally invasive plate osteosynthesis (MIPO) is a recently described method of biological internal fixation performed by introducing a bone plate via small insertional incisions that are remote to the fracture site. Indirect reduction techniques can generally be utilized when performing MIPO. In this case report, we describe MIPO of a radius-ulna fracture by indirect reduction using circular external fixation for alignment and distraction in a dog.

A Study on the Optimal Design of the Arterial in Pusan Area Using the TSM Techniques (TSM기법을 고려한 부산지역 간선도로의 최적설계에 관한 연구)

  • An, H.C.;Kim, T.G.
    • Journal of Korean Port Research
    • /
    • v.7 no.2
    • /
    • pp.19-36
    • /
    • 1993
  • In this study for relieving traffic congestion on the main arterial in Pusan using TSM Techniques, the travel system, roadway system and signal system analyses were dine. Through these above analyses, it was shown that the peak-time periods on the main arterial were shaped between 10 : 00 and 11 : 00 in the morning and between 15 : 00 and 16 : 00 in the afternoon for the business and shopping trips. Especially, there appeared to be about 23% reduction in the average delay when roadway system management including left-turn links increased were done, about 29% reduction in the average delay when signal system management including the signal phases and timings readjusted were conducted, and about 48% reduction in average delay when roadway system and signal system management were taken into consideration simultaneously. Based upon these results, it was concluded that there might be considerably better results in the average delay if the progressive signal system analyses on the arterial were applied with the land and road widths balanced, the difference on the turning vehicles and mid-block volumes readjusted, and roadside parking traffic prohibited.

  • PDF

Techniques for Improving Host-based Anomaly Detection Performance using Attack Event Types and Occurrence Frequencies

  • Juyeon Lee;Daeseon Choi;Seung-Hyun Kim
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.11
    • /
    • pp.89-101
    • /
    • 2023
  • In order to prevent damages caused by cyber-attacks on nations, businesses, and other entities, anomaly detection techniques for early detection of attackers have been consistently researched. Real-time reduction and false positive reduction are essential to promptly prevent external or internal intrusion attacks. In this study, we hypothesized that the type and frequency of attack events would influence the improvement of anomaly detection true positive rates and reduction of false positive rates. To validate this hypothesis, we utilized the 2015 login log dataset from the Los Alamos National Laboratory. Applying the preprocessed data to representative anomaly detection algorithms, we confirmed that using characteristics that simultaneously consider the type and frequency of attack events is highly effective in reducing false positives and execution time for anomaly detection.

Comparison of chemical and photochemical generation of hydrides in Se speciation study with HPLC-HG-ICPMS (HPLC-ICPMS를 이용한 셀레늄 화학종의 연구에서 화학적 및 광화학적 수소화물 발생법의 비교)

  • Ji, Hana;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.339-344
    • /
    • 2012
  • In this research, hydride generation in HPLC-ICPMS for the selenium speciation was investigated. Chemical and photochemical vapor generation techniques were compared for the effective generation of selenium vapour. $HBr/KBrO_3$ was used for the chemical reduction and a UV lamp was used for the photochemical reduction. It was found out that the photochemical reduction was more effective than the chemical reduction in all of selenium species studied. The optimum conditions for the generation of vapour are 0.4% KI, 2.5% $NaBH_4$, and 1.0 M HCl. The enhancement factor using a photochemical hydride generation was from 6.3 to 16.7 times for inorganic and organic selenium species.